American Water Heater 317994-002 Replacing the Flame Sense/Hot Surface igniter Assembly

Page 26

Replacing the Flame Sense/Hot Surface igniter Assembly

1.Remove the manifold/burner assembly. See Removing the Manifold/Burner Assembly.

2.Lift the retainer clip straight up from the back of the manifold component block (using a flat-blade screwdriver), then remove the manifold component block from the manifold door (Figure 26.)

3.Remove and keep the screw securing the flame sense/ hot surface igniter assembly (Figure 26)

4.Remove and discard the old flame sense/hot surface igniter assembly.

5.Route the new flame sense/hot surface igniter con- nector wire through manifold/burner door opening as shown in figure 26. Secure assembly to bracket using screw removed earlier.

Screw

Retainer Clip

Cleaning the Combustion Chamber and Air Diverter Assembly

1.Follow procedure outlined in “Removing the Manifold/ Burner Assembly”.

2.Use a vacuum cleaner/shop vac to remove all loose debris in the combustion chamber (Figure 28). Use compressed air to clear any dust or debris that may have accumulated on the air diverter assembly.

Air Diverter

Combustion

Assembly

Chamber

Manifold

Door Gasket

FIGURE 28.

3.Reassemble following the procedure under “Replacing the Manifold/Burner Assembly”

Manifold Component

Block

Flame Sense/

Hot Surface

Igniter Assembly

Replacing the Manifold/Burner Assembly

WARNING

FIGURE 26.

6.Reposition the manifold component block in the mani- fold door opening and secure it with the retainer clip.

7.See Replacing the Manifold/Burner Assembly.

External Inspection & Cleaning of the Air Intake Chamber Screen

1.At least twice annually inspect the air intake chamber screen (Figure 27) for any dust or debris that may have accumulated on the louvers. NOTE: If the water heater is located in an area that is subjected to lint and dirt,

it may be necessary to check the air intake chamber

screen more frequently.

2. Use a vacuum cleaner with a hose attachment to remove any dust or debris that may have accumulated on the screen.

Air Intake Chamber

Screen

FIGURE 27.

Explosion Hazard

Remove any fiberglass between gasket and combustion chamber.

Replace viewport if glass is missing or damaged.

Replace two piece wire connector if missing or removed.

Replace door gasket if damaged.

Tighten both manifold door screws securely.

Failure to follow these instructions can result in death, explosion, or fire.

1.Check the door gasket for damage or imbedded debris prior to installation.

2.Inspect the view port for damage and replace as required.

26

Image 26
Contents Residential GAS Water Heaters Table of Contents Safe INSTALLATION, USE and Service Safety PrecautionsFire or Explosion Hazard Typical Installation GET to Know Your Water Heater GAS ModelsImportant Information About This Water Heater Installing Your GAS Water HeaterUnpacking the Water Heater Excessive Weight Hazard Consumer InformationCarbon Monoxide Poisoning Hazard Location RequirementsSite Location Clearances and Accessibility State of CaliforniaGas Requirements Gas Pressure TestingGAS Supply Gas PipingGas Pipe Capacity Table Confined Space Combustion AIR & VentilationUnconfined Space Minimum Btuh InputLouvers and Grilles All Air from Inside the BuildingAll Air from Outdoors Draft Hood Installation Vent Pipe SystemChimney Connection Vent ConnectorsVent Pipe Size Vertical Exhaust Gas VentPiping Installation Water System PipingTemperature and Pressure Relief Valve Closed System/Thermal ExpansionCombination Space Heating/Potable Water System Temperature & Pressure Relief ValveRelief Valve and Pipe Insulation Discharge LineElectrical Connections Solar InstallationWiring Diagram Installation Checklist Important Information about this Water HeaterOperating Your Water Heater Operating InstructionsBurn Hazard Water Heater OperationChecking the Draft Emergency Shut Down Water Temperature RegulationBurner Flames Condensation Safety Shut-offOperational Conditions Water Heater SoundsDraining and Flushing Routine Preventive MaintenancePowered Anode Operation Removing the Manifold/Burner Assembly Maintenance of Your Water HeaterReplacement Parts Removing the Burner from the Manifold/ Burner AssemblyReplacing the Manifold/Burner Assembly Replacing the Flame Sense/Hot Surface igniter AssemblyCleaning the Combustion Chamber and Air Diverter Assembly Replacing the Gas Valve Removing and Replacing the Gas Control Valve/ThermostatRemoving the Gas Control Valve/Thermostat Pressurized Combustion Chamber System Operational Checklist Troubleshooting ChartCont Control Display Troubleshooting Control Display Status Problem SolutionControl Display Status Problem Solution FV-SENSE and Open Flashing Troubleshooting Flowchart YESRepair Parts List Repair Parts IllustrationListed Parts Kits and Illustrations