DIP Switch Settings
LOOP START TRUNK
Set switches in black as indicated.
Other switches are at installer’s discretion.
| O | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
1 | N |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
0 |
|
|
|
|
|
|
|
|
|
|
ANNOUNCEMENT TONE |
|
|
|
|
|
|
|
|
|
|
See DIP Switch #3 description |
|
|
|
|
|
|
|
|
|
|
VOX TIMER ENABLE |
|
|
|
|
|
|
|
|
|
|
See DIP Switch #4 description |
|
|
|
|
|
|
|
|
|
|
TRUNK TIMER |
|
|
|
|
|
|
|
|
|
|
See DIP Switch #7 description |
|
|
|
|
|
|
|
|
|
|
TIMER RANGE
See DIP Switch #8/9 description
GROUND START TRUNK
Set switches in black as indicated.
Other switches are at installer’s discretion.
| O | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
1 | N |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
0 |
|
|
|
|
|
|
|
|
|
|
ANNOUNCEMENT TONE |
|
|
|
|
|
|
|
|
|
|
See DIP Switch #3 description |
|
|
|
|
|
|
|
|
|
|
VOX TIMER ENABLE |
|
|
|
|
|
|
|
|
|
|
See DIP Switch #4 description |
|
|
|
|
|
|
|
|
|
|
TRUNK TIMER |
|
|
|
|
|
|
|
|
|
|
See DIP Switch #7 description |
|
|
|
|
|
|
|
|
|
|
TIMER RANGE
See DIP Switch #8/9 description
STATION ACCESS
Set switches in black as indicated.
Other switches are at installer’s discretion.
| O | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
1 | N |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
0 |
|
|
|
|
|
|
|
|
|
|
ANNOUNCEMENT TONE |
|
|
|
|
|
|
|
|
|
|
See DIP Switch #3 description |
|
|
|
|
|
|
|
|
|
|
VOX TIMER ENABLE |
|
|
|
|
|
|
|
|
|
|
See DIP Switch #4 description |
|
|
|
|
|
|
|
|
|
|
ANSWER DELAY |
|
|
|
|
|
|
|
|
|
|
See DIP Switch #5 description |
|
|
|
|
|
|
|
|
|
|
CPC DETECTION |
|
|
|
|
|
|
|
|
|
|
See DIP Switch #6 description |
|
|
|
|
|
|
|
|
|
|
TIMER RANGE
See DIP Switch #8/9 description
1 |
|
|
| STATION | STARTGND | TNCONF | DISVOX |
| IGNORE | TMERTRNK | RANGE (SEC) | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 1<INHIBIT | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
0 |
|
|
| MODETRUNK | STARTLOOP | TNANNPRE | ENABLEVOX |
| IMMEDANS | CPCDETECT | TIMERNO | 0 1<100 - 200 | |||||||||
|
|
|
| 1 0<50 - 100 | |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 0 0<1 - 50 | |||
1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ON | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
N | 1 |
| 2 |
| 3 |
| 4 | 5 |
| 6 |
| 7 |
| 8 | 9 |
| |||||
|
| O |
|
|
|
|
|
|
|
| |||||||||||
0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DIP SW # DIP Switch Function
1Sets unit for either Station access or Trunk (Loop Start and Ground Start) access.
2Determines if Loop Start or Ground Start trunk access will be used.
3Determines if a
4Determines if the VOX timer will operate. Set to 0 to enable the VOX Timer, or 1 to Disable. Only applies to Station Access mode or Trunk Timer feature use.
5Sets unitʼs delay before answering a station access page to immediate answer (set to 0), or to answer after 1st ring burst (set to 1), (station mode only).
6Sets unit to detect (set to 0), or ignore CPC pulse (set to 1). A CPC pulse is issued by certain equipment when the calling party has hung up (station mode only).
7Determines if the Trunk Timer function will be used (set to 0), or not used (set to 1). See Trunk Timer Features section for description of function.
8 / 9 | Switches 8 / 9 are used together to set the range for |
| the Paging Time control or to disable the Paging Default |
timer, 0/0 = 1- 50 sec, 1/0 = 50
IMPORTANT NOTE: DO NOT inhibit all of these disconnect features at once. One of the 3 methods for the TAMB2 to disconnect from a station port must be enabled. If you disable both timers and the
Contact Closures
The contact closure contact set is provided to signal to external equipment the TAMB2ʼs operational state. The contact set is single pole, double throw, and changes state from what is screened below the terminals when the TAMB2 becomes active and returns when the unit becomes idle again.
Contact Ratings: 0.6A @ 125V AC resistive 0.6A @ 110V DC resistive 2.0A @ 30V DC resistive