Cobra Electronics pmnPR3100DX General Specifications, Frequency, Power Supply, Licensing

Page 13

General Specifications

Operation

General Specifications

 

Frequency

 

 

 

 

B. Receiver

 

Unit

Nominal

A. FRS/GMRS

 

 

 

 

 

 

 

 

 

 

Allocation and

 

1.

Sensitivity

 

 

 

 

 

Compatibility

 

 

 

 

 

 

 

 

 

 

For 12 dB SINAD

.

dBm

-121

 

Important: Please note that Cobra®

 

 

 

 

For Call Signal Detection . . .

.

dBm

-121

 

 

2.

Max. Audio Output

 

 

 

 

GMRS models with 15 Channels may

 

 

 

 

 

 

 

@ 10% THD

.

mW

200

 

designate different channel numbers for

 

 

 

 

 

3.

Max. S/N Ratio

 

 

 

 

the same frequency. For example, a

 

 

 

 

 

 

 

 

 

@ 1mV RF Input

 

. dB

50

 

Cobra® 15 Channel GMRS model would

 

 

 

.

 

need to be tuned to Channel 11 in order

4.

Squelch

 

 

 

 

to communicate with a 22 Channel GMRS

 

 

 

a) Sensitivity

.

dBm

-121

 

tuned to Channel 15. Please refer to the

 

 

 

b) Attack Time

. mS

150

 

chart below for channel/ frequency

 

 

 

 

c) Closing Time

. mS

200

 

number compatibility.

 

 

5.

Audio Frequency Response

 

 

 

 

A = Channel No. For

 

 

 

 

 

@ 300 Hz

.

. dB

-3

 

 

 

 

 

 

@ 2500 Hz

 

. dB

-10

 

 

22 Channel GMRS Models

 

 

 

 

.

 

 

 

6.

Signal Displacement BW . . . .

+/-kHz

5

 

B = Channel No. For 15

 

 

 

 

Channel GMRS Models

 

7.

Adjacent Channel Rejection .

.

. dB

60

 

C = Type of Radio Service

 

8.

Intermodulation Rejection . .

.

. dB

65

 

D = Frequency in MHz

 

 

9.

Spurious Response Rejection

 

. dB

55

 

E = Power in Watts

 

 

.

 

 

 

 

 

 

 

 

 

 

 

 

a = 2.0/0.5 (selectable)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit

Nominal

 

 

b = 0.5

 

 

 

 

 

C. Transmitter

 

 

 

 

 

 

 

 

 

 

 

 

 

A

B

C

D

E

 

 

 

 

 

 

 

 

1.

Power

 

 

 

 

 

 

 

 

 

 

 

 

 

1

1

FRS/GMRS

462.5625

a

 

 

 

 

 

 

 

GMRS

.

.W

2

 

2

2

FRS/GMRS

462.5875

a

 

 

 

FRS Only

.mW

500

 

3

3

FRS/GMRS

462.6125

a

 

 

 

 

 

2.

Carrier Frequency Stability

 

±Hz

500

 

4

4

FRS/GMRS

462.6375

a

 

 

 

3.

Modulation Limiting

 

kHz

2.5

 

5

5

FRS/GMRS

462.6625

a

 

 

 

4.

Carrier Attack Time

 

mS

80

 

6

6

FRS/GMRS

462.6875

a

 

 

7

7

FRS/GMRS

462.7125

a

 

5.

Audio Frequency Response

 

 

 

 

8

 

FRS

467.5625

b

 

 

 

. . . . . . . . . . . . . . .@ 300 Hz

.

. dB

-12

 

9

 

FRS

467.5875

b

 

 

 

. . . . . . . . . . . . . .@ 2500 Hz

.

. dB

+6

 

10

 

FRS

467.6125

b

 

6.

. . . . . . . . . .Audio Distortion

. . %

 

11

 

FRS

467.6375

b

 

7.

. . . . . . . . . . . . . .Hum Noise

.

. dB

30

 

12

 

FRS

467.6625

b

 

8.

Transient Frequency Behavior

 

 

30

 

13

 

FRS

467.6875

b

 

 

 

a) TX On

. mS

 

14

 

FRS

467.7125

b

 

 

 

b) TX Off

. mS

5

 

15

11

GMRS

462.5500

a

 

 

 

 

 

 

 

 

16

8

GMRS

462.5750

a

 

 

 

 

 

 

Nominal

 

17

12

GMRS

462.6000

a

 

 

D. Power Supply

 

Unit

 

18

9

GMRS

462.6250

a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19

13

GMRS

462.6500

a

 

 

 

 

 

 

 

 

 

 

 

Battery Life (5:5:90 RATIO)

 

 

 

 

20

10

GMRS

462.6750

a

 

1.

 

 

 

 

21

14

GMRS

462.7000

a

 

 

 

. . . . . .With Alkaline Batteries

. HR

24

 

22

15

GMRS

462.7250

a

 

2.

Battery Operating Range

. V

4.2 - 6.0

20 English

 

 

 

 

Introduction

Operation

Customer Assistance

Warranty

Licensing

For Products Used in the U.S.A.

FCC Licensing Required

This 2-way radio operates on GMRS (General Mobile Radio Service) frequencies which require an FCC (Federal Communications Commission) license. A user must be licensed prior to operating on channels 1 through 7 or 15 through 22, which comprise the GMRS channels of this radio. Serious penalties could result for unlicensed use of GMRS channels, in violation of FCC rules, as stipulated in the Communication Act’s Sections 501 and 502 (amended).

Licensed users will be issued a call sign by the FCC, which should be used for station identification when operating this radio. GMRS users should also cooperate by engaging in permissible transmissions only, avoiding channel interference with other GMRS users, and being prudent with the length

of their transmission time.

For licensing information and application forms, please call the FCC Hotline at 800-418-FORM. Request form #159 and form #605. Questions regarding the license application should be directed to the FCC at 888-CALL-FCC. Additional information is available on the FCC’s website at www.fcc.gov.

Safety Information for microTALK® Radios

Your wireless handheld portable transceiver contains a low power transmitter. When the Talk button is pushed, it sends out radio frequency (RF) signals. The device is authorized to operate at a duty factor not to exceed 50%.

In August 1996, the Federal Communications Commissions (FCC) adopted RF exposure guidelines with safety levels for handheld wireless devices.

Nothing comes close to a Cobra® 21

Image 13
Contents For Assistance In Canada or the U.S.A Making Life Easier And SaferAutomated Help Desk Customer Assistance OperatorsFeatures Backlit LCD Display Product FeaturesBatteries To Install Or Replace Batteries Avoid exposure to extreme temperaturesCaring For Your microTALK Radio Basics To Get You StartedUsing Your Radio Selectable HighLow Power Output Volume To Adjust The VolumeTo Switch From High To Low Power Call ButtonSignal Strength Signal Strength Meter Scrolling Through Mode FunctionsSpeaker/Microphone Jack Speaker/Microphone To Attach Your Speaker/MicrophoneMode Functions To Program a Memory Location Ten 10 Memory LocationsOn the display ThroughChannel Scan To De-Program a Memory LocationTo Scan Channels Privacy Code Scan This will return the radio to Standby modeTo Scan Privacy Codes Transmission. This will return the radio to Standby mode You entered mode functionsPress the Mode button to proceed to other functions Memory Location ScanSetting vibrate + ring To Change Call SettingsChange the call setting Is displayedGeneral Specifications General SpecificationsPower Supply FrequencyProduct Service Licensing and Product ServiceLimited 1-Year Warranty Warranty