Nordyne E3 Connecting Supply Service Wires, Upflow Floor Cutout Locations nominal dimensions

Page 18

REAR WALL OF ENCLOSURE

CENTER LINE

1 3/4" MIN

 

 

 

 

 

(45 mm)

 

 

 

 

 

18 5/8"

 

 

17 1/2"

 

Furnace

 

(445 mm)

 

Outline

(474 mm)

 

 

 

14"

 

 

 

 

 

 

23 3/4"

 

 

 

(356 mm)

 

(604 mm)

 

 

 

 

 

3 1/8"

 

 

 

 

 

(80 mm)

 

 

 

For Optional

 

 

 

 

 

 

 

 

 

 

A/C Or H/P

 

3/4"

5 3/4"

 

 

 

(20 mm)

 

3"

 

 

(147 mm)

 

Furnace

(73 mm)

 

 

 

 

 

 

 

20"

 

Outer Door

 

 

 

 

 

 

(508 mm)

 

Figure 19. Upflow Floor Cutout Locations (nominal dimensions)

-010 model is factory-wired for single-branch supply circuit only.

-012 models are factory-wired for single- branch supply circuit (single-circuit kit in- stalled). Dual-branch circuit can be used by removing factory-installed single-circuit kit (see Figures 20 and 21).

-015, -017, -020 and -023 models are factory-wired for dual-branch supply circuit. Single-branch circuit can be used by installing optional single-circuit kit .

IMPORTANT:

Note: Circuit breakers installed within this unit are for short - circuit protection of the internal wiring and to serve as a disconnect. Circuit breakers installed within this unit DO NOT provide over-current protection of the supply wiring and therefore may be sized larger than the branch circuit protection.

Connecting Supply Service Wires

1.Remove right-hand control panel (when viewing in downfl ow position).

2.Locate power supply hole plugs in side of unit and in bottom of unit. Remove appropriate plug(s) or knockout opening applicable to recommended wire size(s).

3.Installlistedcableconnector(s)inopening(s). If metal-sheathed conduit is used for incom- ing power line(s), provide an approved metal clamp on conduit and secure it in entrance knockout.

4.Insert supply service wire(s) through cable connector(s) and connect wires to circuit breakers (Figures 20 and 21).

NOTE: To install single-circuit kit, perform step 5. If single-circuit kit installation is not necessary, go to step 6.

5.To install single-circuit kit:

a.Loosen lugs at supply side of circuit breakers.

b.Remove cover from single-circuit kit (if supplied).

c.Insert metal buss bars of kit into lugs of circuit breaker.

d.Tighten lugs securely (45 in.-lbs.recom- mended).

18

Image 18
Contents Downflow, Upflow Electric Furnaces E3 Series Air Conditioner/Heat Pump Air HandlerPage Furnace Parts Identification Model IdentificationMaintenance Instructions Optional AIR Conditioner and Heat Pump Before YOU Call a ServicemanSection Installer Information General Overview of E3 FurnaceUnit Checkout CODES, SPECIFICATIONS, and RequirementsMiscellaneous Listings & Installation Requirements Furnace CodesTypical Installation of Downflow Systems or Platinum System Optional EquipmentOptional Accessories Item Number Description Optional Rear Mounting PlateUnit Specifications E3EHSelecting Duct Connector Optional Duct Connectors for Downflow SystemsFloor Cavity Sizes Installing Duct ConnectorPreparing Floor Openings Method a Platinum SeriesRear Mounting Plate Method CPlatinum Duct Connector Method D Method EAlcove Installation Closet InstallationFurnace Installation Typical Installation of Upflow Systems Standard Closet InstallationSpecial 1 Clearance Downflow and Upflow Installations Over-the-Floor Return Air Sys Tem with Upflow StandCodes, Specifications, and Re- quirements Applications and Furnace InstallationElectrical System Installation Over-the-Floor Return Air System Non-DuctedConnecting Supply Service Wires Upflow Floor Cutout Locations nominal dimensionsBlower Installation Selecting Blower SpeedInstalling Control Circuit Wiring Changing Blower SpeedFurnace Blower Speed Data Blower Performance Furnace Thermostat Model Checking InstallationSystem Checkout ClearancesElectrical Specifications 020HE3EB 010H Wiring Diagrams Position Before Servicing the furnaceE3EB 015H, E3EB 017H Wiring Diagrams E3EB 020H, 023H, and 023H 5 Ton, E2EB-015HBR Wiring Diagrams Switch circuit breakers toE3EX 010H E3EX 015/017H Typical AC Furnace Inspection Report Page ¢708827H¤

E3 specifications

The Nordyne E3 is an innovative and efficient heating and cooling system designed to meet the demands of modern residential and commercial spaces. With a focus on energy efficiency and advanced technology, the E3 series offers a variety of features tailored to provide optimal comfort throughout the year.

One of the standout characteristics of the Nordyne E3 is its multi-stage heating and cooling capability. This system utilizes a two-stage compressor, which allows it to operate at different capacities based on the current temperature demand. By adjusting its output, the E3 can maintain a more consistent indoor climate while maximizing energy savings. This not only enhances comfort but also reduces energy bills over time.

The E3 series also includes a variable-speed blower motor, which significantly improves airflow management. This technology enables the system to operate quietly and efficiently, reducing energy consumption while providing precise temperature control. Homeowners can enjoy a comfortable environment without the disruptive noise often associated with traditional HVAC systems.

Another key feature of the Nordyne E3 is its advanced refrigerant technology. The system uses R-410A refrigerant, an environmentally friendly option that has a lower impact on ozone depletion compared to older refrigerants. This commitment to sustainability aligns with the growing demand for eco-friendly solutions in the HVAC industry.

Additionally, the Nordyne E3 incorporates integrated Wi-Fi connectivity, allowing users to control their system remotely via smartphone or tablet. This smart technology enables homeowners to adjust temperature settings, monitor energy usage, and schedule maintenance alerts from virtually anywhere.

Energy Star certification further highlights the E3’s commitment to energy efficiency. Systems bearing this label are rigorously tested to ensure they meet strict guidelines for energy consumption, providing peace of mind for consumers looking to reduce their carbon footprint.

In summary, the Nordyne E3 heating and cooling system stands out for its energy-efficient design, advanced technologies, and commitment to comfort. With features like multi-stage operation, variable-speed motors, eco-friendly refrigerants, and smart home compatibility, it represents a significant step forward in HVAC technology. Homeowners can rely on the E3 to create a comfortable living environment while also contributing to a more sustainable future.