Furnace Inspection Report

 

Please Write In Appropriate

 

 

Response

 

 

 

 

 

Electrical Wiring (If single circuit, write “N/A” in circuit B)

Circuit A

Circuit B

 

Breaker Size?

 

 

 

Furnace Wire Size?

 

 

 

Thermostat Wire Size?

 

 

 

 

 

 

 

 

Please Circle Appropriate

 

 

Response

 

Electrical

 

 

 

Is the furnace grounded properly?

Yes

No

N/A

Is wiring routed safely with approved connectors?

Yes

No

N/A

 

 

 

 

Closet Installation

 

 

 

Is front clearance a minimum of 6 inches?

Yes

No

N/A

Is return air opening a minimum of 235 sq. inches?

Yes

No

N/A

Is front clearance less than 6 inches (minimum of 1 inch)?

Yes

No

N/A

Is return air opening a minimum of 250 sq. inches?

Yes

No

N/A

Does the furnace have the 5-ton AC coil installed?

Yes

No

N/A

Is the return air opening a minimum of 390 sq inches?

Yes

No

N/A

 

 

 

 

Plenum (Base) Connector

 

 

 

Is mounting plate secured properly?

Yes

No

N/A

Is furnace locked and secured in front?

Yes

No

N/A

Is plenum free of debris?

Yes

No

N/A

Has plenum opening been reduced in size to accommodate

Yes

No

N/A

offset?

 

 

 

Has plenum spacer been removed if duct size is large enough?

Yes

No

N/A

 

 

 

 

Testing

 

 

 

Is someone in the plant trained to perform duct tests?

Yes

No

N/A

 

 

 

 

VentilAire III __ IV__

 

 

 

Is VentilAire duct connected properly to furnace?

Yes

No

N/A

Is depressurization vent (if required) installed properly?

Yes

No

N/A

Is roof assembly installed properly?

Yes

No

N/A

Is roof assembly a minimum of 3 inches from any other vents?

Yes

No

N/A

 

 

 

 

General

 

 

 

Is filter in place?

Yes

No

N/A

Is owner’s packet included?

Yes

No

N/A

Checked storage area for damage to product and proper

Yes

No

N/A

storage?

 

 

 

Is installation in accordance with installation instructions?

Yes

No

N/A

 

 

 

 

Comments:

30

Image 30
Contents Downflow, Upflow Electric Furnaces E3 Series Air Conditioner/Heat Pump Air HandlerPage Furnace Parts Identification Model IdentificationMaintenance Instructions Optional AIR Conditioner and Heat Pump Before YOU Call a ServicemanSection Installer Information General Overview of E3 FurnaceUnit Checkout CODES, SPECIFICATIONS, and RequirementsMiscellaneous Listings & Installation Requirements Furnace CodesTypical Installation of Downflow Systems or Platinum System Optional EquipmentOptional Accessories Item Number Description Optional Rear Mounting PlateUnit Specifications E3EHSelecting Duct Connector Optional Duct Connectors for Downflow SystemsFloor Cavity Sizes Installing Duct ConnectorPreparing Floor Openings Method a Platinum SeriesRear Mounting Plate Method CPlatinum Duct Connector Method D Method EAlcove Installation Closet InstallationFurnace Installation Typical Installation of Upflow Systems Standard Closet InstallationSpecial 1 Clearance Downflow and Upflow Installations Over-the-Floor Return Air Sys Tem with Upflow StandCodes, Specifications, and Re- quirements Applications and Furnace InstallationElectrical System Installation Over-the-Floor Return Air System Non-DuctedConnecting Supply Service Wires Upflow Floor Cutout Locations nominal dimensionsBlower Installation Selecting Blower SpeedInstalling Control Circuit Wiring Changing Blower SpeedFurnace Blower Speed Data Blower Performance Furnace Thermostat Model Checking InstallationSystem Checkout ClearancesElectrical Specifications 020HE3EB 010H Wiring Diagrams Position Before Servicing the furnaceE3EB 015H, E3EB 017H Wiring Diagrams E3EB 020H, 023H, and 023H 5 Ton, E2EB-015HBR Wiring Diagrams Switch circuit breakers toE3EX 010H E3EX 015/017H Typical AC Furnace Inspection Report Page ¢708827H¤

E3 specifications

The Nordyne E3 is an innovative and efficient heating and cooling system designed to meet the demands of modern residential and commercial spaces. With a focus on energy efficiency and advanced technology, the E3 series offers a variety of features tailored to provide optimal comfort throughout the year.

One of the standout characteristics of the Nordyne E3 is its multi-stage heating and cooling capability. This system utilizes a two-stage compressor, which allows it to operate at different capacities based on the current temperature demand. By adjusting its output, the E3 can maintain a more consistent indoor climate while maximizing energy savings. This not only enhances comfort but also reduces energy bills over time.

The E3 series also includes a variable-speed blower motor, which significantly improves airflow management. This technology enables the system to operate quietly and efficiently, reducing energy consumption while providing precise temperature control. Homeowners can enjoy a comfortable environment without the disruptive noise often associated with traditional HVAC systems.

Another key feature of the Nordyne E3 is its advanced refrigerant technology. The system uses R-410A refrigerant, an environmentally friendly option that has a lower impact on ozone depletion compared to older refrigerants. This commitment to sustainability aligns with the growing demand for eco-friendly solutions in the HVAC industry.

Additionally, the Nordyne E3 incorporates integrated Wi-Fi connectivity, allowing users to control their system remotely via smartphone or tablet. This smart technology enables homeowners to adjust temperature settings, monitor energy usage, and schedule maintenance alerts from virtually anywhere.

Energy Star certification further highlights the E3’s commitment to energy efficiency. Systems bearing this label are rigorously tested to ensure they meet strict guidelines for energy consumption, providing peace of mind for consumers looking to reduce their carbon footprint.

In summary, the Nordyne E3 heating and cooling system stands out for its energy-efficient design, advanced technologies, and commitment to comfort. With features like multi-stage operation, variable-speed motors, eco-friendly refrigerants, and smart home compatibility, it represents a significant step forward in HVAC technology. Homeowners can rely on the E3 to create a comfortable living environment while also contributing to a more sustainable future.