Nordyne E3 user service Electrical Specifications, 020H

Page 22

Model

 

 

Maximum

Minimum

Copper Wire Size - See

Ground

Low

Supply

Total

Caution Below

Voltage

Number

Over-current

Circuit

Wire

Circuit

Amperes

60°C

90°C

Thermostat

E3E(*)

Rating

Ampacity

Size

 

 

(e.g., Romex)

(e.g., SEU)

Wire Size

 

 

 

 

 

 

-010H

Single

45.5

60

57

4

6

10

2-Wire system

 

Single

52.1

70

65

4

6

8

-012H

maximum wire

Dual "A"

28.0

40

35

8

8

10

lengths:

 

Dual "B"

24.2

30

30

10

10

10

 

24 Ga.= 55'

 

Single

66.3

90

83

2

4

8

-015H

22 Ga.= 90'

Dual "A"

45.5

60

56

4

6

10

20 Ga.= 140'

 

Dual "B"

20.8

30

26

10

10

10

 

18 Ga.= 225'

-017H

Single

71.3

90

89

2

4

8

 

Dual "A"

48.8

60

60

4

6

10

4 or more

 

Dual "B"

22.5

30

28

10

10

10

Wire systems

-020H

Single

87.1

125

109

0

2

6

maximum wire

Dual "A"

45.5

60

57

4

6

10

lengths:

 

Dual "B"

41.7

60

52

4

6

10

24 Ga.= 25'

 

Single

93.8

125

117

0

2

6

22 Ga.= 45'

-023H

Dual "A"

52.1

60

60

4

6

10

20 Ga.= 70'

 

Dual "B"

41.7

60

56

4

6

10

18 Ga= 110'

Model

 

 

Maximum

Minimum

Copper Wire Size - See

Ground

Low

Supply

Total

Caution Below

Voltage

Number

Over-current

Circuit

Wire

Circuit

Amperes

60°C

90°C

Thermostat

E3EX

Rating

Ampacity

Size

 

 

(e.g., Romex)

(e.g., SEU)

Wire Size

 

 

 

 

 

 

-010

Single

47.7

60

57

4

6

10

2-Wire system

-012

Single

54.3

70

67

4

6

8

maximum wire

Dual "A"

30.2

40

35

8

8

10

lengths:

 

Dual "B"

24.2

30

30

10

10

10

24 Ga.= 55'

 

Single

66.0

90

83

2

4

8

22 Ga.= 90'

-015

Dual "A"

46.0

60

57

4

6

10

20 Ga.= 140'

 

Dual "B"

20.0

30

25

10

10

10

18 Ga.= 225'

-017

Single

71.5

90

89

2

4

8

4 or more

Dual "A"

51.0

60

60

4

6

10

Wire systems

 

Dual "B"

22.5

30

28

10

10

10

maximum wire

-020

Single

86.0

125

109

0

2

6

lengths:

Dual "A"

46.0

60

57

4

6

10

24 Ga.= 25'

 

Dual "B"

40.0

60

50

4

6

10

22 Ga.= 45'

Replacement furnace for E2E(*)-015HB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E2E(*)-

Single

67.1

90

83

2

4

8

Replacement

Dual "A"

35.5

50

44

6

8

10

furnace for

015HBR

Dual "B"

31.7

40

39

8

8

10

E2E(*)-015HB

 

* Can be H or B

CAUTION: When sizing the wire, you must follow the guidelines of the latest revision of the NEC. NM-B wire is equivalent to “Romex” cable. SEU is equivalent to service entry cable. For NEC type NM-B wire, you must size the wire using 60C ratings per NEC article 326.

* Minimum overcurrent protection per NEC 424-3b not to be less than 125% of total amps for fi xed resistance heat.

Table 9a. Electrical Specifications

 

Circuit "A"

Circuit "B"

Model Number

Wire Gauge

 

Breaker

Wire Gauge

Breaker

E3E(*)

and Type

 

Size

and Type

Size

-012H

#8 NM-B

 

40 amp

#10 NM-B

30 amp

-015H

#6 SEU

 

60 amp

#10 NM-B

30 amp

-017H

#6 SEU

 

60 amp

#10 NM-B

30 amp

-020H

#6 SEU

 

60 amp

#6 SEU

60 amp

-023H

#6 SEU

 

60 amp

#6 SEU

60 amp

Replacement furnace for E2E(*)-015HB

 

 

 

E2E(*)-015HBR

#8 SEU

 

50 amp

#8 NM-B

40 amp

Table 9b. Recommended Electrical Application Guide

for Dual Circuit Installations**

**Alternate wiring combinations can be used. Refer to the latest revision of the NEC for these appropriate alternate combinations.

22

Image 22
Contents Downflow, Upflow Electric Furnaces E3 Series Air Conditioner/Heat Pump Air HandlerPage Furnace Parts Identification Model IdentificationMaintenance Instructions Optional AIR Conditioner and Heat Pump Before YOU Call a ServicemanSection Installer Information General Overview of E3 FurnaceUnit Checkout CODES, SPECIFICATIONS, and RequirementsMiscellaneous Listings & Installation Requirements Furnace CodesTypical Installation of Downflow Systems or Platinum System Optional EquipmentOptional Accessories Item Number Description Optional Rear Mounting PlateUnit Specifications E3EHSelecting Duct Connector Optional Duct Connectors for Downflow SystemsFloor Cavity Sizes Installing Duct ConnectorPreparing Floor Openings Method a Platinum SeriesRear Mounting Plate Method CPlatinum Duct Connector Method D Method ECloset Installation Alcove InstallationFurnace Installation Standard Closet Installation Typical Installation of Upflow SystemsSpecial 1 Clearance Downflow and Upflow Installations Over-the-Floor Return Air Sys Tem with Upflow StandCodes, Specifications, and Re- quirements Applications and Furnace InstallationElectrical System Installation Over-the-Floor Return Air System Non-DuctedConnecting Supply Service Wires Upflow Floor Cutout Locations nominal dimensionsBlower Installation Selecting Blower SpeedChanging Blower Speed Installing Control Circuit WiringFurnace Blower Speed Data Blower Performance Furnace Thermostat Model Checking InstallationSystem Checkout ClearancesElectrical Specifications 020HE3EB 010H Wiring Diagrams Position Before Servicing the furnaceE3EB 015H, E3EB 017H Wiring Diagrams E3EB 020H, 023H, and 023H 5 Ton, E2EB-015HBR Wiring Diagrams Switch circuit breakers toE3EX 010H E3EX 015/017H Typical AC Furnace Inspection Report Page ¢708827H¤

E3 specifications

The Nordyne E3 is an innovative and efficient heating and cooling system designed to meet the demands of modern residential and commercial spaces. With a focus on energy efficiency and advanced technology, the E3 series offers a variety of features tailored to provide optimal comfort throughout the year.

One of the standout characteristics of the Nordyne E3 is its multi-stage heating and cooling capability. This system utilizes a two-stage compressor, which allows it to operate at different capacities based on the current temperature demand. By adjusting its output, the E3 can maintain a more consistent indoor climate while maximizing energy savings. This not only enhances comfort but also reduces energy bills over time.

The E3 series also includes a variable-speed blower motor, which significantly improves airflow management. This technology enables the system to operate quietly and efficiently, reducing energy consumption while providing precise temperature control. Homeowners can enjoy a comfortable environment without the disruptive noise often associated with traditional HVAC systems.

Another key feature of the Nordyne E3 is its advanced refrigerant technology. The system uses R-410A refrigerant, an environmentally friendly option that has a lower impact on ozone depletion compared to older refrigerants. This commitment to sustainability aligns with the growing demand for eco-friendly solutions in the HVAC industry.

Additionally, the Nordyne E3 incorporates integrated Wi-Fi connectivity, allowing users to control their system remotely via smartphone or tablet. This smart technology enables homeowners to adjust temperature settings, monitor energy usage, and schedule maintenance alerts from virtually anywhere.

Energy Star certification further highlights the E3’s commitment to energy efficiency. Systems bearing this label are rigorously tested to ensure they meet strict guidelines for energy consumption, providing peace of mind for consumers looking to reduce their carbon footprint.

In summary, the Nordyne E3 heating and cooling system stands out for its energy-efficient design, advanced technologies, and commitment to comfort. With features like multi-stage operation, variable-speed motors, eco-friendly refrigerants, and smart home compatibility, it represents a significant step forward in HVAC technology. Homeowners can rely on the E3 to create a comfortable living environment while also contributing to a more sustainable future.