Heat Controller BG-123A, BG-81A, BG-101A HOW to Install, Items in Installation Hardware

Page 13
Remove old air conditioner from existing wall sleeve.
Clean the interior of an existing sleeve. (Do not disturb seals.)

3.2INSTALLATION

CAUTION

Installing the Heat Controller sleeve ensures optional performances of the unit.

If you decide to keep the existing wall sleeve, you have to redirect the louvers at the back of the wall sleeve. Refer to FIG. 23 on p15. The use of pliers is recommended. If you DO NOT redirect, you run the risk

of poor performance or premature product failure. This is not covered under the terms of the Heat Controller

warranty.

Pick a location which will allow the conditioned air to blow into the area you want. Good installation with special attention to the proper position of the unit will lessen the chance that service will be needed.

ITEMS IN INSTALLATION HARDWARE

You may not need all parts in the kit. Discard unused parts

ITEM (inches)

 

Qty.

Plastic grille

 

263/4 x 161/2

1

 

Vertical insulation strip

 

159/16 x 13/8 x 13/8

1

 

Around Insulation Strips

 

671/8 x 13/8 x 25/32

1

 

 

5927/32 x 13/8 x 13/8

1

 

 

 

 

Horizontal Insulation Strip

 

237/32 x 13/8 x 13/16

1

 

Support Block

 

13/4 x 13/8 x 45/16

2

 

Baffle

 

14 x 41/2 x 1/8

1

 

Shim

 

1113/16 x 1 x 3/4

2

 

Trim Frame

 

 

2

 

Washer Screw

 

 

4

 

Nuts(Plastic)

 

 

4

 

Grille Rear

 

 

1

 

HOW TO INSTALL

1 Before installing the unit, identify the existing wall sleeve

from the list below.

 

 

 

 

 

 

 

Brand

Wall Sleeve Dimensions (inches)

Width

Height

Depth

 

White-Westinghouse

 

 

16, 17-1/2

Frigidaire

25-1/2

15-1/4

or 22

Carrier (52F series)

 

 

 

 

 

General Electric

26

15-5/8

16-7/8

/Hotpoint

 

 

 

Whirlpool

25-7/8

16-1/2

17-1/8

or 23

 

 

 

Fedders/Emerson

27

16-3/4

16-3/4

Friedrich WSC

or 19-3/4

 

 

FRIEDRICH USC

25-7/8

15-17/32

16-23/32

Emerson/Fedders

26-3/4

15-3/4

15

Carrier (51S Series)

25-3/4

16-7/8

18-5/8

NOTE: All wall sleeves used to mount the new Air Conditioner must be in sound structural condition and have a rear grille that securely attaches to sleeve, or rear flange that serves as a stop for the Air Conditioner.

2

3

Wall sleeve must be securely fastened in wall before

4 installing the air conditioner. Use the nails or screws through sleeve into wall, if needed. Repaint sleeve if needed.

Prepare the wall sleeve for installation of the unit. If you

5 plan to use your existing wall sleeve, and it is not FRIEDRICH, use procedure B or C below.

Procedure

Brand

Depth(inches)

A(page 16)

FRIEDRICH USC

16-23/32

 

White-Westinghouse

16, 17-1/2

 

Frigidaire Carrier

 

or 22

B

(52F series)

 

General Electric

 

(pages 17~18)

16-7/8

/Hotpoint

 

 

 

Whirlpool

17-1/8 or 23

 

Carrier (51S series)

18-5/8

C

Fedders/Emerson

16-3/4

Friedrich WSC

or 19-3/4

(pages 19)

Emerson/Fedders

15

 

 

 

 

6 Install new unit into wall sleeve.

CAUTION: When installation is completed, replacement unit MUST have a rearward slope as shown. To achieve 1/4" slope, remove the backing from the 11-13/16" shim strips and attach them as shown below in Fig. 19. Place the higher portion of shim to the front of the rib on base of wall sleeve.

1" high

3/4" High

 

 

UNIT

Wall Sleeve

Shim

FRONT

 

 

 

6"

1/4"

 

6"

 

SHIM PLACEMENT

UNIT INSTALLATION

 

 

FIG. 19

13

Image 13
Contents Heat CONTROLLER, INC Preface ContentsModels Items Control Locations FeaturesCooling only Model Operation VentilationMechanical Parts Disassembly InstructionsFront Grille CabinetORIFICE, and Turbo FAN AIR Handling PartsCompressor Electrical PartsCapacitor Thermistor Power CordCondenser Refrigeration CycleEvaporator Capillary TubePage Pulling Vacuum Installation Requirements InstallationInstallation Hardware Electrical ServiceItems in Installation Hardware HOW to InstallToassembletrim,tpthetabofeachpiece Procedure aTop View Procedure BWall Wall sleeve inches Procedure CParts and Installation Outside Dimensions Troubleshooting GuidePiping System Troubleshooting Guide Fails to Start Complaint Cause Remedy Room AIR Conditioner Voltage Limits Complaint Cause Remedy Circuit Diagram Schematic DiagramHeat CONTROLLER, INC

BG-101A, BG-123A, BG-81A specifications

The Heat Controller series, comprising BG-81A, BG-101A, and BG-123A, represents a new benchmark in energy-efficient temperature management solutions. Engineered for both residential and commercial applications, these models offer versatility, reliability, and innovative technology designed to enhance user comfort while minimizing energy consumption.

The BG-81A model is compact yet powerful, making it an ideal choice for smaller spaces or individual rooms. Its key features include a programmable thermostat, allowing users to set specific heating schedules tailored to their needs. The BG-81A employs advanced inverter technology, which ensures that the unit maintains desired temperatures with minimal temperature fluctuations. This feature not only improves comfort levels but also significantly reduces energy costs by optimizing power usage.

Moving up in capacity, the BG-101A boasts enhanced heating capabilities suitable for medium-sized areas. It is equipped with a dual heating mode, allowing users to switch between energy-saving and high-efficiency settings. This flexibility makes the BG-101A adaptable to various environmental conditions, providing reliable warmth during the coldest months. Additionally, it features a built-in air purification system that ensures the delivery of high-quality air by trapping dust, allergens, and other particulates, benefiting users with respiratory sensitivities.

At the top of the lineup, the BG-123A is designed for larger spaces, combining robust performance with cutting-edge technology. It incorporates smart connectivity features, allowing users to control the heating system remotely via a mobile app. This functionality not only enhances convenience but also aids in energy management, as users can monitor and adjust settings in real time. The BG-123A also has an advanced temperature sensor that adapts the heating output based on the specific needs of the environment, ensuring optimal comfort while conserving energy.

All three models feature quiet operation, ensuring they can effectively function in bedrooms or offices without disrupting daily activities. Additionally, they are designed with user-friendly interfaces and minimal maintenance requirements, making them accessible for a wide range of users.

Overall, the Heat Controller BG series exemplifies modern heating solutions, combining efficiency, smart technology, and user-centric design for an unparalleled heating experience.