Heat Controller BG-101A, BG-81A, BG-123A Procedure a, Toassembletrim,tpthetabofeachpiece

Page 14

PROCEDURE A

1

If you are using the new sleeve (optionally

 

supplied with your unit),skip to step 3.

Otherwise, install the plastic grille from the kit. Cut the plastic grille to 25-1/2" wide and

15-1/4" high. Place the plastic grille to the inside of the wall sleeve at the rear flange.

FIG.20

2 Fasten the 4 washer screws to secure the grille to the wall sleeve. If you need plastic nuts to mount plastic grille to the inside of the wall sleeve, there are plastic nuts in the installation kit. The nuts are installed from the inside of the sleeve and are pressing into the square holes of the rear flanges.Fasten the bracket to the upside of the wall sleeve using the washer screw. The bracket prevents the unit from leaving the sleeve.

Bracket

 

Bracket

Fasten the screws and the bracket

or

FIG.21

3 Remove the backing from the Vertical Insulation strip 159/16 x 13/8 x 13/8 and attach that to the inside right of the sleeve as shown below. Remove the backing from the Around Insulation strip 671/8 x 13/8 x 25/32 and attach that to the inside front of the sleeve as shown below.

Indoor

Outdoor

Around Insulation

 

9 1/2"

6"

 

FIG. 22

4

Install the new unit into the wall sleeve.

5

Toassembletrim,tpthetabofeachpiece

into the slot of the other piece as shown below.

Slide trim over the front of the air conditioner until trim is flush with sleeve as shown below.

Trim (2 ea)

Wall

FIG.23

CAUTION

Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit.

To prevent injury or strain, use proper lifting and carrying techniques when moving unit.

When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils.

Make sure air conditioner does not fall during removal.

If unit does not operate after installation check, to be sure the circuit interrupter has not been tripped. Refer to the Troubleshooting guide for reset procedure.

14

Image 14
Contents Heat CONTROLLER, INC Contents PrefaceModels Items Cooling only Model Operation FeaturesControl Locations VentilationFront Grille Disassembly InstructionsMechanical Parts CabinetAIR Handling Parts ORIFICE, and Turbo FANCapacitor Electrical PartsCompressor Power Cord ThermistorEvaporator Refrigeration CycleCondenser Capillary TubePage Pulling Vacuum Installation Hardware InstallationInstallation Requirements Electrical ServiceHOW to Install Items in Installation HardwareProcedure a Toassembletrim,tpthetabofeachpieceProcedure B Top ViewWall Procedure C Wall sleeve inchesParts and Installation Piping System Troubleshooting GuideOutside Dimensions Troubleshooting Guide Fails to Start Complaint Cause Remedy Room AIR Conditioner Voltage Limits Complaint Cause Remedy Schematic Diagram Circuit DiagramHeat CONTROLLER, INC

BG-101A, BG-123A, BG-81A specifications

The Heat Controller series, comprising BG-81A, BG-101A, and BG-123A, represents a new benchmark in energy-efficient temperature management solutions. Engineered for both residential and commercial applications, these models offer versatility, reliability, and innovative technology designed to enhance user comfort while minimizing energy consumption.

The BG-81A model is compact yet powerful, making it an ideal choice for smaller spaces or individual rooms. Its key features include a programmable thermostat, allowing users to set specific heating schedules tailored to their needs. The BG-81A employs advanced inverter technology, which ensures that the unit maintains desired temperatures with minimal temperature fluctuations. This feature not only improves comfort levels but also significantly reduces energy costs by optimizing power usage.

Moving up in capacity, the BG-101A boasts enhanced heating capabilities suitable for medium-sized areas. It is equipped with a dual heating mode, allowing users to switch between energy-saving and high-efficiency settings. This flexibility makes the BG-101A adaptable to various environmental conditions, providing reliable warmth during the coldest months. Additionally, it features a built-in air purification system that ensures the delivery of high-quality air by trapping dust, allergens, and other particulates, benefiting users with respiratory sensitivities.

At the top of the lineup, the BG-123A is designed for larger spaces, combining robust performance with cutting-edge technology. It incorporates smart connectivity features, allowing users to control the heating system remotely via a mobile app. This functionality not only enhances convenience but also aids in energy management, as users can monitor and adjust settings in real time. The BG-123A also has an advanced temperature sensor that adapts the heating output based on the specific needs of the environment, ensuring optimal comfort while conserving energy.

All three models feature quiet operation, ensuring they can effectively function in bedrooms or offices without disrupting daily activities. Additionally, they are designed with user-friendly interfaces and minimal maintenance requirements, making them accessible for a wide range of users.

Overall, the Heat Controller BG series exemplifies modern heating solutions, combining efficiency, smart technology, and user-centric design for an unparalleled heating experience.