Heat Controller BG-123A Features, Control Locations, Cooling only Model Operation, Ventilation

Page 4

1.4 FEATURES

Designed for cooling only.

Powerful and quiet cooling.

Top-down chassis for the simple installation and service.

1.5 CONTROL LOCATIONS

1.5.1COOLING ONLY MODEL

• OPERATION

FAN SPEED

Side air-intake, side cooled-air discharge.

Built in adjustable THERMISTOR and THERMOSTAT.

Washable one-touch filter.

Compact size.

Every time you push this button, it advances the setting as follows: {High Low Med High}

Cool

 

F1 LOW

Energy

 

F2 MED

 

F3 HIGH

Saver

 

 

Fan

 

 

 

Timer

TEMP

 

 

FAN

MODE TIMER SPEED

TIMER

- SHUT-OFF TIME

REMOTE CONTROL SIGNAL RECEIVER

'F

TEMPERATURE SETTING

Use this button to automatically control the temperature of the room.

The temperature can be set within a range of 60°F to 86°F by increments of 1°F.

The setting appears in the display.

POWER POWER

To turn the air conditioner ON, push this button.

To turn the air conditioner OFF, push the button again.

This button takes priority over any other button.

When you first turn it on, the unit is in cool mode, High fan speed, Temperature setting at 72°F.

You will usually use shut-off time while you sleep.

If unit is running, use Timer to set number of hours until shut-off.

For your sleeping comfort, once Time is set, the Temperature setting will raise 2°F after 30 min., and once again after another 30 min.

Push Timer button to advance setting from 1Hour 2Hours ... 12Hours maximum.

-START TIME

If unit is off, use Timer to set number of hours before unit starts.

Push Timer button to advance setting from 1Hour 2Hours ... 12Hours maximum.

MODE

-Push this button to shift mode of operation from COOL ENERGY SAVER FAN.

-COOL:

Fan runs continually for normal cooling operation.

-ENERGY SAVER:

The fan stops when the compressor stops cooling. Approximately every 3 minutes the fan will turn on and the unit will check the room air temperature to determine if cooling is needed.

-FAN:

Fan-only operation.

VENTILATION

Push the lever to the "CLOSE" position to cool, heat or recirculate room air only.

Pull the lever to the "OPEN" position to exhaust smoke or stale air from the room.

This feature is best used in conjunction with the FAN ONLY position.

CAUTION

 

When the air conditioner has been operating in the

cooling and is turned off or set to the fan

only position,

wait at least 3 minutes before resetting to the cooling

operation again.

PULL OPEN / PUSH CLOSE

4

Image 4
Contents Heat CONTROLLER, INC Contents PrefaceModels Items Features Control LocationsCooling only Model Operation VentilationDisassembly Instructions Mechanical PartsFront Grille CabinetAIR Handling Parts ORIFICE, and Turbo FANCompressor Electrical PartsCapacitor Power Cord ThermistorRefrigeration Cycle CondenserEvaporator Capillary TubePage Pulling Vacuum Installation Installation RequirementsInstallation Hardware Electrical ServiceHOW to Install Items in Installation HardwareProcedure a Toassembletrim,tpthetabofeachpieceProcedure B Top ViewWall Procedure C Wall sleeve inchesParts and Installation Outside Dimensions Troubleshooting GuidePiping System Troubleshooting Guide Fails to Start Complaint Cause Remedy Room AIR Conditioner Voltage Limits Complaint Cause Remedy Schematic Diagram Circuit DiagramHeat CONTROLLER, INC

BG-101A, BG-123A, BG-81A specifications

The Heat Controller series, comprising BG-81A, BG-101A, and BG-123A, represents a new benchmark in energy-efficient temperature management solutions. Engineered for both residential and commercial applications, these models offer versatility, reliability, and innovative technology designed to enhance user comfort while minimizing energy consumption.

The BG-81A model is compact yet powerful, making it an ideal choice for smaller spaces or individual rooms. Its key features include a programmable thermostat, allowing users to set specific heating schedules tailored to their needs. The BG-81A employs advanced inverter technology, which ensures that the unit maintains desired temperatures with minimal temperature fluctuations. This feature not only improves comfort levels but also significantly reduces energy costs by optimizing power usage.

Moving up in capacity, the BG-101A boasts enhanced heating capabilities suitable for medium-sized areas. It is equipped with a dual heating mode, allowing users to switch between energy-saving and high-efficiency settings. This flexibility makes the BG-101A adaptable to various environmental conditions, providing reliable warmth during the coldest months. Additionally, it features a built-in air purification system that ensures the delivery of high-quality air by trapping dust, allergens, and other particulates, benefiting users with respiratory sensitivities.

At the top of the lineup, the BG-123A is designed for larger spaces, combining robust performance with cutting-edge technology. It incorporates smart connectivity features, allowing users to control the heating system remotely via a mobile app. This functionality not only enhances convenience but also aids in energy management, as users can monitor and adjust settings in real time. The BG-123A also has an advanced temperature sensor that adapts the heating output based on the specific needs of the environment, ensuring optimal comfort while conserving energy.

All three models feature quiet operation, ensuring they can effectively function in bedrooms or offices without disrupting daily activities. Additionally, they are designed with user-friendly interfaces and minimal maintenance requirements, making them accessible for a wide range of users.

Overall, the Heat Controller BG series exemplifies modern heating solutions, combining efficiency, smart technology, and user-centric design for an unparalleled heating experience.