Haier AB52NACBEA, AB42NACBEA, AB28NACBEA, AB36NACBEA, AB242ACBEA Meanings of Warning and Cautions

Page 21

Installation Procedure

CAUTIONS: To ensure proper installation, read "Cautions" carefully before working. After installation, start the unit correctly and show customers how to operate and

maintain the unit.

Meanings of Warning and Cautions:

Warning! Serious injury or even death might happen, if it is not observed. Caution! Injury to people of damages to machine might happen, if it is not observed.

WARNING!

Installation shall be done by professional people, don't install unit by yourself. Incorrect installation will cause water leakage, electric shock or fire.

Install unit as per the Manual. Incorrect installation will cause water leakage, electric shock or fire accident.

Be sure to use specified accessaries and parts. Otherwise, water leakage, electric shock, fire accident or unit falling down may happen.

Unit should be placed on a place strong enough to hold the unit. Or, unit will fall down causing injuries. When install the unit, take in consideration of storms, typhoom, earthquake. Incorrect installation may cause unit to fall down.

All electric work shall be done by experienced people as per eocal code, regulations and this Manual. Use exclusive wire for the unit. Incorrect installation or undersized electric wire may cause electric shock or fire accident.

All the wires and circuit shall be safe. Use exclusive wire firmly fixed. Be sure that external force will not affect terminal bolck and electric wire. Poor contact and installation may cause fire accident. Arrange wire correctly when connectin indoor and outdoor power supply. Fix terminal cover firmly to avoid overheat, electric shock or even fire accident.

In case retrigerant leakage occurred during unit installation, keep a good ventilation in the room. Poisonous gas will occur when meet with fire.

Check the unit upon installation. Be sure there is no leakage. Refrigerant will induce poisonous gas when meet heat source as heater, oven, etc.

Cut power supply before touching terminal bolck.

CAUTION!

Unit shall be grounded. But grounding shall not be connected to gas pipe water pipe, telephone line. Poor grounding will cause electric shock.

Be sure to install a leakage breaker to avoid electric shock.

Arrange water drainage according to this Manual. Cover pipe with insulation materials in case

Earthing

 

dew may occur. Unproper installation of water drainage will cause water leakage and wer your furniture. To maintain good picture or reduce noise, keep at least 1 m from T.V. radio, when install indoor and ou tdoor unit, connecting wire and power line. (If the radio wave is relatively strong, 1 m is not enough

to reduce noise).

Don't install unit in following places:

(a)Oil mist or oil gas exists, such as kitchen, or, plastic parts may got aged, or water leakage.

(b)Where there is corrosive gas. Copper tube and welded part may be damaged due to corrosion, causing leakage.

(c)Where there is strong radiation. This will affect unit's control system, causing malfunction of the unit

(d)Where flamable gas, dirt, and volatile matter (thinner, gasoline) exist, These matter might cause fire accident.

Refer to paper pattern when installing unit.

Cautions for the installation personnel

Don't fail to show customers how to operate unit.

19

Image 21
Contents No.0010572475 Operation & Installation ManualContents Disposal of the old air conditioner Applicable ambient temperature range Refrigerating circuit is leak-proofMachine is adaptive in following situation Safety cautions Dont dismantle the outlet of the outdoor unit Wiring LocationOperating noise Suction grill Introduction to Spare PartsDrain Hose Swing fender Refrigerant pipe Cable line Earthing lineClean the unit MaintenanceClean the air filter Clean indoor outdoor unitClean Install air filterOpen inlet grill Open two othooks Dismantle air filterInstall inlet grill Take off air-filter Take of inlet grill CleanInstall swing plate Close inlet grillOpen Instruction Pre-season Care Seasonal Reserve Post-season CareFollowings are not malfuncition Trouble ShootingOFF Cooled air blown out when heating When Trouble HappensInsufficient cooling or heating Insufficient cooling Indoor coil temp. sensor failure Using Directions Customer Need-to-knowCustomer Need-to-know Installation tools Installation ProcedureMeanings of Warning and Cautions Before Installation Selection of Installation PlaceDont discard any accessories until comp Installation example Preparation for the InstallationAfter installation on the ceiling Installation of Indoor UnitCase of new ceiling Case of ceiling already existsPipe Tighten Amm Flare shape Size Torque Installation of Water Drainage Pipe3 N L 3 Y/G Limits of panel board installation When wiring is not complete After wiringWiring Wiring ExampleInstallation of Ornament Panel Mounting on high ceiling Installation of inlet grill and cover plate Haier Group

AB28NACBEA, AB42NACBEA, AB242ACBEA, AB142ACBEA, AB52NACBEA specifications

Haier, a global leader in home appliances and consumer electronics, has an impressive lineup of air conditioning units designed to meet the diverse needs of modern consumers. Among their notable offerings are the Haier AB36NACBEA, AB182ACBEA, AB52NACBEA, AB142ACBEA, and AB242ACBEA models. Each of these air conditioning units showcases a synthesis of innovative technology, energy efficiency, and user-friendly features, making them ideal for various residential and commercial applications.

The Haier AB36NACBEA is a robust air conditioning unit designed to deliver powerful cooling performance. It features advanced inverter technology, which not only enhances cooling efficiency but also reduces energy consumption. This model includes various operating modes and a user-friendly remote control, allowing for convenient adjustments based on user preferences. Its sleek design and aesthetic appeal make it a great fit in any setting.

Next, the AB182ACBEA unit is characterized by its compact size yet powerful output. It is perfect for smaller spaces or individual rooms. The AB182ACBEA operates quietly, ensuring minimal disruption while maintaining a comfortable environment. With energy-saving capabilities and a built-in air purification system, this model promotes not only temperature regulation but also improved air quality.

The Haier AB52NACBEA stands out due to its high cooling capacity. This unit is engineered for larger spaces, ensuring consistent temperature control even during peak summer conditions. Its multi-stage filtration system helps remove dust and allergens from the air, providing a healthier living environment. The user's comfort is further enhanced by its intuitive digital display and programmable timer.

The AB142ACBEA model specializes in maintaining a balanced climate. It features both cooling and heating functions, making it versatile for use throughout the year. The energy-efficient operation helps consumers reduce their electricity bills while maintaining optimal indoor comfort. It also boasts a self-diagnosis feature that aids in troubleshooting common issues.

Finally, the AB242ACBEA is designed for high performance in a wide range of conditions. Equipped with powerful compressors and advanced cooling technology, this unit ensures prompt cooling even in extreme temperatures. It incorporates smart connectivity, allowing users to control the air conditioner via smartphone apps, making temperature management convenient and accessible.

Together, these Haier air conditioning units exemplify the brand's commitment to quality, efficiency, and user-centric design, making them a smart choice for consumers looking to enhance their indoor climate. Each model's specific features cater to various preferences and requirements, ensuring an ideal solution for every user.