Haier AB52NACBEA, AB42NACBEA, AB28NACBEA Wiring Example, Installation of Ornament Panel

Page 28
Accessory Pad

Installation Procedure

7. WIRING

All supplied parts. materials and wiring operation must in appliance with local code and regulations.

Use copper wire only.

When make wiring, please refer to wiring diagram also. All wiring work must be done by qualified electricians.

A circuit breaker must be installed, which can cut power supply to all system.

See Installation Manual of outdoor unit for specifications of wires, circuit breaker, switches and wiring etc. Connecting of unit

Remove cover of switch box (1) , drag wires into rubber tube A, then, after proper wiring with other wires, tighten clamp A. Connect wires of correct pole to the terminal block inside.

Wind seal 12 around wires. (Be sure to do that, or, dew may occur). Upon connecting, replace control box cover (1) and (2).

Terminal block

Grounding lead Rubber tube A

Cover of control box(1)

Cover of control box(2)

*Don't fail to seal it, or water may come in.

Rubber tube Note: Have it sealed, leaving no space.

Seal pad (small size 12 ) (Wind around wire)

In Out

Attach seal pad Field wiring

<<WARNING>>

Obscrve the following when connecting power supply terminal block:

Don't connect wires of different specifications to the same terminal block.

(Loose wire may cause overheating of circuit)

Connect wires of same specifications as shown in right Fig.

Connect wires of the

Don't connect wires of

Don't connect wires

same specifications

the same specifications

of the different

at two sides.

at one side.

specifications.

8. WIRING EXAMPLE

 

 

As for outdoor unit circuit, please see Installation Manual of outdoor unit.

 

 

Note: All electric wires have their own poles, poles must match that on terminal block.

 

99. INSTALLATION OF ORNAMENT PANEL

Bar

Fig. 1

Cautions for the installation

 

 

 

Be sure to show customers Operation Manual and guide them how to operate unit correctly. Before installation. read also the Installation Manual of indoor unit. With this ornament , 2 or 3 air flow direction is not available.

Suitable height is 3 m.

Pad

1. Prepare ornament panel Handling of ornament panel

Ornament panel shall not be placed face down or against wall, neither on an uneven object.

Don' t bend carelessly the swing flap, or, problem may occur.

(1)Remove air inlet grill from ornament panel *

1Push in the bar on inlet grill and lift it up. (Refer to Fig. 1)

2Lift it up for about 45 degree and remove it from ornament. Tear off adhesive tape fixing air filter on the back of the air inlet grill. (Refer to Fig. 2)

(2)Remove cover plate at corner

Tear off the adhesive tape, and slide it off. (Refer to Fig. 3)

45

Adbesive tape

 

 

Fig. 2

Slide

Fig. 3

26

Image 28
Contents Operation & Installation Manual No.0010572475Contents Disposal of the old air conditioner Refrigerating circuit is leak-proof Applicable ambient temperature rangeMachine is adaptive in following situation Safety cautions Dont dismantle the outlet of the outdoor unit Location WiringOperating noise Introduction to Spare Parts Suction grillDrain Hose Swing fender Refrigerant pipe Cable line Earthing lineMaintenance Clean the unitClean the air filter Clean indoor outdoor unitInstall air filter CleanOpen inlet grill Open two othooks Dismantle air filterTake off air-filter Take of inlet grill Clean Install inlet grillInstall swing plate Close inlet grillOpen Instruction Seasonal Reserve Post-season Care Pre-season CareTrouble Shooting Followings are not malfuncitionOFF When Trouble Happens Cooled air blown out when heatingInsufficient cooling or heating Insufficient coolingIndoor coil temp. sensor failure Customer Need-to-know Using DirectionsCustomer Need-to-know Installation Procedure Installation toolsMeanings of Warning and Cautions Selection of Installation Place Before InstallationDont discard any accessories until comp Preparation for the Installation Installation exampleInstallation of Indoor Unit After installation on the ceilingCase of new ceiling Case of ceiling already exists Installation of Water Drainage Pipe Pipe Tighten Amm Flare shape Size Torque3 N L 3 Y/G Limits of panel board installation After wiring When wiring is not completeWiring Example WiringInstallation of Ornament Panel Mounting on high ceiling Installation of inlet grill and cover plate Haier Group

AB28NACBEA, AB42NACBEA, AB242ACBEA, AB142ACBEA, AB52NACBEA specifications

Haier, a global leader in home appliances and consumer electronics, has an impressive lineup of air conditioning units designed to meet the diverse needs of modern consumers. Among their notable offerings are the Haier AB36NACBEA, AB182ACBEA, AB52NACBEA, AB142ACBEA, and AB242ACBEA models. Each of these air conditioning units showcases a synthesis of innovative technology, energy efficiency, and user-friendly features, making them ideal for various residential and commercial applications.

The Haier AB36NACBEA is a robust air conditioning unit designed to deliver powerful cooling performance. It features advanced inverter technology, which not only enhances cooling efficiency but also reduces energy consumption. This model includes various operating modes and a user-friendly remote control, allowing for convenient adjustments based on user preferences. Its sleek design and aesthetic appeal make it a great fit in any setting.

Next, the AB182ACBEA unit is characterized by its compact size yet powerful output. It is perfect for smaller spaces or individual rooms. The AB182ACBEA operates quietly, ensuring minimal disruption while maintaining a comfortable environment. With energy-saving capabilities and a built-in air purification system, this model promotes not only temperature regulation but also improved air quality.

The Haier AB52NACBEA stands out due to its high cooling capacity. This unit is engineered for larger spaces, ensuring consistent temperature control even during peak summer conditions. Its multi-stage filtration system helps remove dust and allergens from the air, providing a healthier living environment. The user's comfort is further enhanced by its intuitive digital display and programmable timer.

The AB142ACBEA model specializes in maintaining a balanced climate. It features both cooling and heating functions, making it versatile for use throughout the year. The energy-efficient operation helps consumers reduce their electricity bills while maintaining optimal indoor comfort. It also boasts a self-diagnosis feature that aids in troubleshooting common issues.

Finally, the AB242ACBEA is designed for high performance in a wide range of conditions. Equipped with powerful compressors and advanced cooling technology, this unit ensures prompt cooling even in extreme temperatures. It incorporates smart connectivity, allowing users to control the air conditioner via smartphone apps, making temperature management convenient and accessible.

Together, these Haier air conditioning units exemplify the brand's commitment to quality, efficiency, and user-centric design, making them a smart choice for consumers looking to enhance their indoor climate. Each model's specific features cater to various preferences and requirements, ensuring an ideal solution for every user.