Large size seal pad 10
(accessory)
4mm below below500
Table 1

Installation Procedure

5. REFRIGERANT PIPING (As for outdoor piping, please refer to installation Manual of outdoor unit.)

Outdoor is precharged with refrigerant.

Be sure to see the Fig.1, when connecting and removing piping from unit.

For the size of the flare nut, please refer to Table 1.

Apply refrigerant oil at both inside and outsid of lflare nut. Tighten it band tight 3-4 turns then tighten it.

Use torque specified in Table 1. (Too much force may damage flare nut, causing gas leakage).

Check piping joints for gas leakage. Insulate piping as shown in Fig. below. Cover joint of gas piping and insulator 7 with seal.

Apple refrigerant oil

Torque spanner

spanner

Piping joing

Flare nut

Medium size seal pad 11 (accessory)

(Cover the piping joint with seal pad.)

Clamp 3

Insulator (accessory) 8 (For liquid pipe)

Insulator (accessory) 7 Gas pipe (For gas pipe)

Liquid pipe

Pipe

Tighten

A(mm)

 

Flare shape

size

torque

 

 

 

 

 

6.35

1420~1720N.cm

8.3~8.7

 

 

 

 

(144~176kgf.cm)

 

 

 

9.52

3270~3990N.cm

12.0~12.4

 

2

R0.4 ~ 0.8

 

(333~407kgf.cm)

0.5

 

6180~7540N.cm

 

45

A

 

18.6~19.0

 

 

15.88 (630~770kgf.cm)

90

 

19.05

9720~11860N.cm

22.9~23.3

 

 

 

(990~1210kgf.cm)

 

 

 

6. INSTALLATION OF WATER DRAINAGE PIPE

(1) Install water drainage pipe

Pipe dia, shall be equal or larger than that of unit piping.(pipe of polyethylent; size: 25mm; O.D:32mm)

Drain pipe should be short, with a downward slope at least 1/100 to prevent air bag from happening.

If downward slope can't be made, take other measures to lift it up.

Keep a distance of 1-1.5m between suspending brackets, to make water hose straight.

1-1.5m

Slope over 1/100

Use the self-provided stiff pipe and clamp 1 with unit. Insert water pipe into water plug until it reaches the white tape. Tighten the clip until head of the screw is less than 4mm from hose.

Wind the drain hose to the clip using seal pad 9 . Insulate drain hose in the room.

Tape (White)

Clamp

Clamp (accessory)

Self-provided stiff pipe

<Cautions for the drain water lifting pipe>

Installation height shall be less than 280mm.

There should be a right angle with unit, 300mm from unit.

Drain hose (accessory)

(Note)

300mm below 1~1.5m

Suspending bracket

 

280220below

500below

drain water lifting pipe

 

Clamp (accessory)

Self-provided stiff pipe

(accessory) below75

The slope of water drain hose (1) shall be within 75mm, don't apply too much force on it. If several water hoses join together, do as per following proceedures.

Over 100

Connect water hoses with a T joint.

Specifieations of the water hoses shall meet the requirements for the unit running.

23

Image 25
Contents No.0010572475 Operation & Installation ManualContents Disposal of the old air conditioner Refrigerating circuit is leak-proof Applicable ambient temperature rangeMachine is adaptive in following situation Safety cautions Dont dismantle the outlet of the outdoor unit Location WiringOperating noise Suction grill Introduction to Spare PartsDrain Hose Swing fender Refrigerant pipe Cable line Earthing lineClean the unit MaintenanceClean the air filter Clean indoor outdoor unitClean Install air filterOpen inlet grill Open two othooks Dismantle air filterInstall inlet grill Take off air-filter Take of inlet grill CleanInstall swing plate Close inlet grillOpen Instruction Pre-season Care Seasonal Reserve Post-season CareFollowings are not malfuncition Trouble ShootingOFF Cooled air blown out when heating When Trouble HappensInsufficient cooling or heating Insufficient coolingIndoor coil temp. sensor failure Customer Need-to-know Using DirectionsCustomer Need-to-know Installation tools Installation ProcedureMeanings of Warning and Cautions Selection of Installation Place Before Installation Dont discard any accessories until comp Installation example Preparation for the InstallationAfter installation on the ceiling Installation of Indoor UnitCase of new ceiling Case of ceiling already existsPipe Tighten Amm Flare shape Size Torque Installation of Water Drainage Pipe3 N L 3 Y/G Limits of panel board installation When wiring is not complete After wiringWiring Example WiringInstallation of Ornament Panel Mounting on high ceiling Installation of inlet grill and cover plate Haier Group

AB28NACBEA, AB42NACBEA, AB242ACBEA, AB142ACBEA, AB52NACBEA specifications

Haier, a global leader in home appliances and consumer electronics, has an impressive lineup of air conditioning units designed to meet the diverse needs of modern consumers. Among their notable offerings are the Haier AB36NACBEA, AB182ACBEA, AB52NACBEA, AB142ACBEA, and AB242ACBEA models. Each of these air conditioning units showcases a synthesis of innovative technology, energy efficiency, and user-friendly features, making them ideal for various residential and commercial applications.

The Haier AB36NACBEA is a robust air conditioning unit designed to deliver powerful cooling performance. It features advanced inverter technology, which not only enhances cooling efficiency but also reduces energy consumption. This model includes various operating modes and a user-friendly remote control, allowing for convenient adjustments based on user preferences. Its sleek design and aesthetic appeal make it a great fit in any setting.

Next, the AB182ACBEA unit is characterized by its compact size yet powerful output. It is perfect for smaller spaces or individual rooms. The AB182ACBEA operates quietly, ensuring minimal disruption while maintaining a comfortable environment. With energy-saving capabilities and a built-in air purification system, this model promotes not only temperature regulation but also improved air quality.

The Haier AB52NACBEA stands out due to its high cooling capacity. This unit is engineered for larger spaces, ensuring consistent temperature control even during peak summer conditions. Its multi-stage filtration system helps remove dust and allergens from the air, providing a healthier living environment. The user's comfort is further enhanced by its intuitive digital display and programmable timer.

The AB142ACBEA model specializes in maintaining a balanced climate. It features both cooling and heating functions, making it versatile for use throughout the year. The energy-efficient operation helps consumers reduce their electricity bills while maintaining optimal indoor comfort. It also boasts a self-diagnosis feature that aids in troubleshooting common issues.

Finally, the AB242ACBEA is designed for high performance in a wide range of conditions. Equipped with powerful compressors and advanced cooling technology, this unit ensures prompt cooling even in extreme temperatures. It incorporates smart connectivity, allowing users to control the air conditioner via smartphone apps, making temperature management convenient and accessible.

Together, these Haier air conditioning units exemplify the brand's commitment to quality, efficiency, and user-centric design, making them a smart choice for consumers looking to enhance their indoor climate. Each model's specific features cater to various preferences and requirements, ensuring an ideal solution for every user.