Haier HFU-18H03/R2(DB) Tool necessary, Standard accessories, No. Shape and description

Page 26

Installation Manual of Room Air Conditioner

Tool necessary

1.Screw driver 2.Hacksaw

3.70mm dia. hole core drill 4.Spanner(dia.17,27mm) 5.Spanner(14,17,27mm) 6.Pipe cutter

7.Flaring tool 8.Knife 9.Nipper

10.Gas leakage detector or soap water

11.Measuring tape 12.Reamer 13.Refrigerant oil

No. Shape and description

QTY

Remote controller

1

Drain hose

1

Plastic cap

4

Drain-elbow

1

Self-tapping screw

4

Rubber pad

4

dry battery #7

2

Floor fixing dimensions of the outdoor unit(Unit:mm)

Standard accessories

Following parts shall be field supplied

Mark

Part name

AAdhensive tape

BPipe clip

CConnecting hose

DInsulation material

EDrain hose

140

105

500

500

256

140

310

105

310

HFU-09H03/R2(DB) HFU-12H03/R2(DB) HFU-18H03/R2(DB)

HFU-09HA03(B)/R1

HFU-12HA03(B)/R1

105

550

105

Fixing of the unit

1. Position of the wall hole

Wall hole should be decided according to installation place and piping direction.(refer to installation drawings).

2. Making a wall hole

Drill a hole of 120x70mm dia. with a little slope towards outside.

Indoor side

Outdoor side

Wall hole

Thickness

 

of wall

(Cross section of wall hole)

25

Image 26
Contents Floor Unit No.0010557172Disposal of the packaging of your new air conditioner Machine is adaptive in following situation SpecificationsApplicable ambient temperature range Refrigerating circuit is leak-proofSafety Instruction OFF Strict Enforcement Outdoor unit Parts and FunctionsIndoor unit Filter insideAir flow selection When setting the air flow selection switch toWhen setting the air outlet selection switch to Remote Controller Parts and Functions Auto Operation Remote controllerOperation Cool Operation Then Select Cool operationDRY Operation Then Select DRY operationThen Select FAN operation FAN OperationAbout FAN operation Heat Operation Then Select Heat operationAdjusting the Air Flow Direction Adjusting the flapSleep Operation Timer On/Off Operation Set clock correctly before starting Timer operationTimer On-Off Operation Then select your desired Timer mode Timer on OFFPower Operation Soft OperationUnit start None 23 oCTo cancel Power failure resumeplease set and apply as necessarySetting method Operation hintsMaintenance Cleaning of the unitMaintenance at the end of application season Trouble shooting Before asking for service, check the following firstInstallation of indoor unit Installation of outdoor unitTool necessary Standard accessoriesFloor fixing dimensions of the outdoor unitUnitmm No. Shape and descriptionPiping connection Piping connection of the indoor unitPurging MethodFor R410A Open ClosePurging MethodFor R407C Wiring of outdoor unit Electric wiringWiring of indoor unit Outdoor unit PowerCut pipe Remove burs Insert the flare nut Flare pipe OthersFlare tooling die

HFU-12H03/R2(DB), HFU-12HA03(B)/R1, HFU-09H03/R2(DB), HFU-18H03/R2(DB), HFU-09HA03(B)/R1 specifications

Haier, a renowned global leader in home appliances, offers a variety of air conditioning units designed for optimal comfort and efficiency. Among its extensive range, the models 0010557172, HFU-09HA03(B)/R1, HFU-18H03/R2(DB), HFU-09H03/R2(DB), and HFU-12HA03(B)/R1 stand out due to their advanced features and technologies suitable for both residential and commercial applications.

The model 0010557172 serves as a prime example of Haier's commitment to energy efficiency. This unit boasts a high Energy Efficiency Ratio (EER), ensuring that it provides maximum cooling while minimizing electricity costs. The incorporation of intelligent inverter technology allows for seamless adjustments in cooling capacity, which not only enhances comfort but also reduces energy consumption.

The HFU-09HA03(B)/R1 is designed with user-friendly controls that allow for easy operation. Equipped with a remote control, this model provides convenience by allowing users to adjust settings from anywhere in the room. Its compact design makes it ideal for smaller spaces, promoting efficient use without compromising comfort. The inclusion of a sleep mode feature ensures quieter operation during the night, enhancing sleep quality.

In contrast, the HFU-18H03/R2(DB) is a powerful unit suitable for larger spaces. With its robust cooling capacity, it is perfect for environments where maintaining a constant temperature is crucial. This model features multi-functional modes, including cooling, heating, and dehumidification, offering year-round comfort regardless of external weather conditions. The unit also incorporates a smart filter system that effectively purifies the air, ensuring a healthier living environment.

The HFU-09H03/R2(DB) and HFU-12HA03(B)/R1 models emphasize durability and easy maintenance. Both models are equipped with self-cleaning technology, which automatically removes dust and impurities from the filter, prolonging the unit's lifespan. Additionally, these models are designed with an environmentally friendly refrigerant that complies with global regulations, minimizing their carbon footprint.

In summary, Haier's lineup of air conditioning units, including the 0010557172, HFU-09HA03(B)/R1, HFU-18H03/R2(DB), HFU-09H03/R2(DB), and HFU-12HA03(B)/R1, showcases a blend of innovative technologies and practical features. With a commitment to efficiency, comfort, and sustainability, Haier continues to meet the diverse needs of consumers in today's dynamic market, ensuring an optimal living and working environment.