Haier HSU-07HV03, HSU-09HV03, HSU-12HV03, HSU-18HV03, HSU-22HV03, HSU-12HVB03 Sleep Operation

Page 16

Operation

Sleep Operation

Before going to bed, you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep.

Use of SLEEP function

After the unit starts, set the operation status, then press SLEEP button before which the clock must be adjusted and time being set. Operation Mode

1. In COOL,DRY mode

1 hours after SLEEP mode starts, temp. will become 1OC higher than temp. setting. After another 1 hours, temp. rises by 1OC further.

The unit will run for further 6 hours then stops. Temp. is higher than temp. setting so that room temperature won't be too Iow for your sleep.

Remote Controller

POWER/SOFT

SLEEP operation starts

SLEEP operation stops

 

 

Approx.6hrs

 

1 hr

Rises 1OC

1 hr

Rises 1OC

 

 

Temp.setting

 

Unit stop

 

 

In COOL, DRY mode

2.In HEAT mode

1 hours after SLEEP mode starts, temp will become 2 OC lower than temp. setting. After another 1 hours, temp decrease by 2 OC further. After more another 3 hours, temp. rises by 1OC further. The unit will run for further 3 hours then stops. Temp. is lower than temp. setting so that room temperature won't be too high for your sleep.

Temp.setting

Unit stop

1 hr

Decreases 2OC

 

 

1 hr

 

 

Decreases 2OC

 

 

3 hrs

 

3 hrs

Rises 1OC

SLEEP

 

SLEEP

 

operation stops

operation starts

 

In HEAT mode

3.In AUTO mode

The unit operates in corresponding sleep mode adapted to the automatically selected operation mode.

4.In FAN mode

It has no SLEEP function.

5.Set the wind speed change when sleeping If the wind speed is high or middle before setting for the sleep, set for lowing the wind speed after sleeping.

If it is low wind, no change. 6.Note to the power failure resume:

press the sleep button ten times in five seconds and enter this function after hearing four sounds. And press the sleep button ten times within five seconds and leave this function after hearing two sounds.

NOTE: With the power failure resume, when setting

the TIMER ON, TIMER OFF and TIMER ON/OFF, itís memorized as shutdown status when resuming after power out.

15

Image 16
Contents Split Type Room AIR Conditioner New air conditioner Disposal of the packaging of yourContain no fluorochloric hydrocarbon Specifications Applicable ambient temperature rangeMachine is adaptive in following situation Refrigerating circuit is leak-proofSafety Instruction Check proper installation of the drainage securelyOFF Strict Enforcement Indoor unit Outdoor unitReset POWER/SOFT Remote controller OperationSelect operation mode Auto OperationUnit start Fan speed selectionSelect temp.setting Cool OperationDry Operation Fan Operation About FAN operationHeat Operation Air Flow Direction Adjustment Status display of air sendingUp and down air flow direction Left and right air flow directionSleep Operation Timer On/Off Operation Time settingConfirming your setting Cancel Timer modeTimer On-Off Operation Power Operation POWER/SOFT OperationSoft Operation Setting of health airflow function Cancel of the health airflow functionHealth airflow Operation Press ON/OFF to startingIt is not possible to operate in dry mode Removal of the restriction of emergency or test operationSetting of proper room Temperature Or outletDo not use the following for cleaning Remote ControllerAir Filter cleaning Open the lnlet Grille Detach the standard air filterAttach old Air Purifying Filter Attach the standard air filterOperate in cooling mode for 2-3 hours To Keep Your Air conditioner in Good Condition after SeasonCleaning the standard air filter Connecting the earthing cableDo not block the air inlet or outlet Plug-in Incomplete earthing may cause an electric shockTrouble shooting Before asking for service, check the following first