Haier HSU-07HV03, HSU-09HV03, HSU-12HV03, HSU-18HV03, HSU-22HV03, HSU-12HVB03 operation manual

Page 21

Operation

Emergency and Test Operation

Emergency operation:

Use this operation only when the remote controller is defective or lost.

When the emergency operation switch is pressed,the" Pi "sound is heard once, which means the start of this operation.

In this operation, the system automatically selects the operation modes, cooling or heating, according to the room temperature.

Temperature

Operation

Designated

Timer

Air flow

 

mode

temperature

mode

 

ABOVE 23OC

COOLING

26OC

NO

AUTOMATIC

BELOW 23OC

HEATING

23OC

NO

AUTOMATIC

It is not possible to operate in dry mode.

Test operation:

Test operation switch is the same as emergency switch.

Use this switch in the test operation when the room temperature is below 16OC, do not use it in the normal operation.

Continue to press the test operation switch for more than 5 seconds. After you hear the "Pi" sound twice, release your finger from the switch: the cooling operation starts with the air flow speed "Hi".

After 30 minutes, test operation ends automatically.

Removal of the restriction of emergency or test operation

Press the emergency operation switch once more, or manipulate through the remote controller; the "Pi" sound, the emergency or test operation is terminated.

When the remote controller is manipulated, it gets the system back to the normal operation mode.

20

Image 21
Contents Split Type Room AIR Conditioner Disposal of the packaging of your New air conditionerContain no fluorochloric hydrocarbon Applicable ambient temperature range SpecificationsMachine is adaptive in following situation Refrigerating circuit is leak-proofCheck proper installation of the drainage securely Safety InstructionOFF Strict Enforcement Outdoor unit Indoor unitReset POWER/SOFT Operation Remote controllerAuto Operation Select operation modeUnit start Fan speed selectionCool Operation Select temp.settingDry Operation About FAN operation Fan OperationHeat Operation Status display of air sending Air Flow Direction AdjustmentUp and down air flow direction Left and right air flow directionSleep Operation Time setting Timer On/Off OperationConfirming your setting Cancel Timer mode Timer On-Off Operation POWER/SOFT Operation Power OperationSoft Operation Cancel of the health airflow function Setting of health airflow functionHealth airflow Operation Press ON/OFF to startingRemoval of the restriction of emergency or test operation It is not possible to operate in dry modeTemperature Or outlet Setting of proper roomRemote Controller Do not use the following for cleaningAir Filter cleaning Detach the standard air filter Open the lnlet GrilleAttach old Air Purifying Filter Attach the standard air filterTo Keep Your Air conditioner in Good Condition after Season Operate in cooling mode for 2-3 hoursConnecting the earthing cable Cleaning the standard air filterDo not block the air inlet or outlet Plug-in Incomplete earthing may cause an electric shockBefore asking for service, check the following first Trouble shooting