Parts and Functions
19
28
30
1.RESET
When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote controller normal.
2.LIGHT button
Control the lightening and extinguishing of the indoor LED display board.
3. TIMER button
Used to select TIMER ON, TIMER OFF,
TIMER
4. CLOCK button
Used to set correct time.
5. SLEEP button
Used to select sleep mode.
6. MODE button
16 | 31 | 10 | 14 | 21 | 15 |
10. TIMER ON display
11. FAN SPEED display
LOW | MED | HI | AUTO |
12.LOCK display
13.SWING UP/DOWN display
14.SLEEP display
15.HEALTH display
16.Operation mode display
Operation mode AUTO COOL DRY HEAT FAN
Remote controller
Display board
17.Singal sending display
18.POWER/SOFT display
19.Left/right air flow display
20.TEMP display
Remote controller: to display the TEMP. setting.
21.TIMER OFF display
22.TIMER display
23.TEMP button
Used to select your desired temperature.
24.FAN button
Used to select fan speed: LOW,MED, HI, AUTO.
25.HEALTH AIRFLOW button
Used to set the health airflow mode.
26.SWING UP/DOWN button
Used to select up or down air sending direction.
27.SWING LEFT/RIGHT button
Used to select left/right air flow.
28.SET button
Used to confirm timer and clock settings.
29.POWER/SOFT button
Every time the button is pressed,display changes
as follows: | BLANK |
AUTO COOL DRY FAN HEAT
30. LOCK
POWER SOFT
7.HOUR button
Used to set clock and timer setting.
8.HEALTH button
Used to set healthy operation.
9.ON/OFF button
Used for unit start and stop.
Used to lock buttons and LCD display. If pressed, the other buttons will be disabled and the lock condition display appears. Press it once again, lock will be canceled and lock condition display disappears.
31. Ambient temp.display
When receiving the remote control signal, display the set temperature and in the rest time the room temperature is displayed and this room temperature is only for reference.
NOTE:Cooling only unit do not have functions and displays related with heating.