Haier HSU-22HRA03/R2 installation manual Necessary Tools for Installation, Power Source

Page 1

Installation Manual of Room Air Conditioner

Preparation

 

Necessary Tools for Installation

● Driver

● Torque wrench

● Nipper

(17mm,22mm,26mm)

● Hacksaw

● Pipe cutter

● Hole core drill

● Flaring tool

● Spanner(17,19 and 26mm)

● Knife

● Gas leakage detector or

● Measuring tape

soap-and-water solution

● Reamer

Power Source

Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate.

Install an exclusive branch circuit of the power.

A receptacle shall be set up in a distance where the power cable can be reached.Do not extend the cable by cutting it.

Selection of Installation Place

Indoor Unit

Place, robust not causing vibration, where the body can be supported sufficiently.

Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the unit are not disturbed.

Place, possible to drain easily, where piping can be connected with the outdoor unit.

Place, where cold air can be spread in a room entirely.

Place, nearby a power receptacle, with enough space around. (Refer to drawings).

Place where the distance of more than lm from televisions, radios, wireless apparatuses and fluorescent lamps can be left.

In the case of fixing the remote controller on a wall, place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened.

Outdoor Unit

Place, which is less affected by rain or direct sunlight and is sufficiently ventilated.

Place, possible to bear the unit, where vibration and noise are not increased.

Place, where discharged wind and noise do not cause a nuisance to the neighbors.

Place, where a distance marked is available as illustrated in the above figure.

Drawing for the installation of indoor and outdoor units

The models adopt HFC free refrigerant R410A

more than 5cm

more than 10cm

Arrangement of piping directions

 

Rear left

Left

Rear

 

right

Right

Below

more than 10cm

The marks from A to G in the figure are the parts numbers.

The distance between the indoor unit and the floor should be more than 2m.

more than 60cm

Attention must be paid to the rising up of drain hose

G

more than 10cm

F

A

C

more than10cm

D

E

Optional parts for piping

ANon-adhesive tape B Adhesive tape

C Saddle (L.S) with screws

DConnecting electric cable for indoor and outdoor

EDrain hose

FHeating insulating material G Piping hole cover

Floor fixing dimensions of the outdoor unit (Unit:mm)

5 . 9 1 3

113.5

583

113.5

Fixing of outdoor unit

Fix the unit to concrete or block with bolts (10mm) and nuts firmly and horizontally.

When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails or wires in consideration of earthquake and strong wind.

If vibration may affect the house, fix the unit by attaching a vibration-proof mat.

more than15cm

Please be subject to the actual product purchased , the above picture is just for your reference.

Read this manual before installation

Explain sufficiently the operating means to the user according to this manual

NO.0010506358