Installation Procedure

CAUTIONS: To ensure proper installation, read "Cautions" carefully before working. After installation, start the unit correctly and show customers how to operate and maintain the unit.

Meanings of Warning and Cautions:

Warning! Serious injury or even death might happen, if it is not observed. Caution! Injury to people of damages to machine might happen, if it is not observed.

WARNING!

Installation shall be done by professional people, don't install unit by yourself. Incorrect installation will cause water leakage, electric shock or fire.

Install unit as per the Manual. Incorrect installation will cause water leakage, electric shock or fire accident.

Be sure to use specified accessaries and parts. Otherwise, water leakage, electric shock, fire accident or unit falling down may happen.

Unit should be placed on a place strong enough to hold the unit. Or, unit will fall down causing injuries. When install the unit, take in consideration of storms, typhoom, earthquake. Incorrect installation may cause unit to fall down.

All electric work shall be done by experienced people as per eocal code, regulations and this Manual. Use exclusive wire for the unit. Incorrect installation or undersized electric wire may cause electric shock or fire accident.

All the wires and circuit shall be safe. Use exclusive wire firmly fixed. Be sure that external force will not affect terminal bolck and electric wire. Poor contact and installation may cause fire accident. Arrange wire correctly when connectin indoor and outdoor power supply. Fix terminal cover firmly to avoid overheat, electric shock or even fire accident.

In case retrigerant leakage occurred during unit installation, keep a good ventilation in the room. Poisonous gas will occur when meet with fire.

Check the unit upon installation. Be sure there is no leakage. Refrigerant will induce poisonous gas when meet heat source as heater, oven, etc.

Cut power supply before touching terminal bolck.

CAUTION!

Unit shall be grounded. But grounding shall not be connected to gas pipe water pipe, telephone line. Poor grounding will cause electric shock.

Be sure to install a leakage breaker to avoid electric shock.

Arrange water drainage according to this Manual. Cover pipe with insulation materials in case Earthing dew may occur. Unproper installation of water drainage will cause water leakage and wet your furniture.

To maintain good picture or reduce noise, keep at least 1 m from T.V. radio, when install indoor and ou- tdoor unit, connecting wire and power cable. (If the radio wave is relatively strong, 1 m is not enough to reduce noise).

Don't install unit in following places:

(a)Oil mist or oil gas exists, such as kitchen, or, plastic parts may get aged, or water leakage.

(b)Where there is corrosive gas. Copper tube and welded part may be damaged due to corrosion, causing leakage.

(c)Where there is strong radiation. This will affect unit's control system, causing malfunction of the unit

(d)Where flamable gas, dirt, and volatile matter (thinner, gasoline) exist, These matter might cause fire accident.

Refer to paper pattern when installing unit.

Cautions for the installation personnel

Don't fail to show customers how to operate unit.

16

Image 18
Contents No.0010576722A Please keep this manual carefully and safelyContents Disposal of the old air conditioner Machine is adaptive in following situation Applicable ambient temperature rangeRefrigerating circuit is leak-proof H05RN-F 2¡`1.0~1.5mm2Safety cautions Otherwise will suffer damage Inefficient venti- lation may cause suffocationFalling of goods and people may cause acci- dents Otherwise will be shockedWiring LocationOperating noise Introduction to Spare Parts Maintenance Install swing plate Take off airfilter Take of inlet grill CleanInstall inlet grill Close inlet grillSeasonal Reserve Post-season Care Pre-season CareTrouble Shooting Followings are not malfuncitionUnit is stopped Atically stopsInsufficient cooling or heating When Trouble HappensCooled air blown out when heating Insufficient coolingError display Indoor unit malfunction display code Outdoor unit malfunction display codeCustomer Need-to-know Using DirectionsEffectively use timer Customer Need-to-knowInstallation Procedure SymbolRefer to paper pattern when installing unit Meanings of Warning and CautionsBefore Installation Selection of Installation PlaceInstallation space Preparation for the Installation 620Insert Installation of Indoor UnitPolythene pipe Secure the washer firmlyInstallation of Water Drainage Pipe Pipe Tighten Amm Flare shape Size TorqueInstalling the Decorated Board on the Body of Indoor Unit Indoor unit Sealing Ceiling materialDecorated board Side of decorated board AB184~484FCAHADifferent from the actual condition Heat down gradient Shape elbow Cleat5m~2m support bracket Insulating over 1/100 Over 1/100 MaterialPiping Heat InsulatingConnecting method of circular terminal is ConnectingBy installation personnel according to After connecting line is completed, pressElectrical Wiring Field setting OFFUnit has temperature compensation function Technical Specifications

AB124FAAHA, AB484FCAHA, AB244FCAHA, AB184FCAHA, AB094FAAHA specifications

Haier has emerged as a leading manufacturer of high-performance refrigeration units, and its models AB424FCAHA, AB094FAAHA, AB184FCAHA, AB244FCAHA, and AB484FCAHA are standout examples. Each model boasts unique features tailored to meet the diverse needs of consumers, while simultaneously utilizing innovative technology to ensure energy efficiency and reliable performance.

The AB424FCAHA is designed with optimal storage capacity in mind. It offers adjustable shelving and a spacious interior that accommodates larger items easily. With a robust cooling system, it ensures that items are preserved at the ideal temperature. This model incorporates a frost-free operation, eliminating the need for manual defrosting, which saves time and energy.

In contrast, the AB094FAAHA is an excellent choice for smaller living spaces. Despite its compact size, it doesn’t compromise on performance. It includes energy-efficient features that help reduce electricity bills while maintaining freshness and quality of stored items. Its sleek design allows it to blend seamlessly into modern kitchens or dorm rooms.

The AB184FCAHA stands out with its advanced cooling technology, providing precise temperature control. This ensures that food items are kept at their ideal temperatures, extending their shelf life. Additionally, the model includes smart functionalities like temperature alarms that alert users in case of any fluctuations, thereby ensuring food safety.

The AB244FCAHA offers a perfect balance between capacity and energy efficiency. This model is equipped with an inverter compressor, which adjusts the cooling power according to the load. This feature not only saves energy but also significantly reduces noise levels compared to traditional compressors. It’s an ideal option for those seeking a quiet appliance without compromising on performance.

Finally, the AB484FCAHA caters to larger households or those needing considerable storage capacity. This model integrates advanced technologies such as multi-air flow systems that evenly distribute cool air throughout the unit. It also features LED lighting for better visibility, making it easier to find items at any time. With its exceptional storage solutions and high-performance capabilities, it stands out as a top choice for large families or meal preppers.

In conclusion, the Haier AB series showcases a diverse range of features and innovative technologies, ensuring that there is an optimal refrigerator solution for every individual’s needs. Whether for small apartments or larger households, Haier continues to meet the demands of modern consumers with style and efficiency.