Use of thread locking compounds

When assembling flying hardware to TCS series loudspeaker enclosures it is advisable to use thread-locking compounds to eyebolts and other bolts in order to avoid any possibility of loosening.

The recommended thread-locking compound is Loctite 222.

The threaded rigging points used in TCS series enclosures are manufactured from zinc- plated mild steel. Therefore, and additionally if the external bolts used are zinc-plated, zinc-passivated, stainless steel or anodised (as the majority are), then the corresponding activator, Loctite 7471, should be used to achieve 100% performance.

Application: Spray Loctite 7471 into the thread holes and allow to evaporate. Apply Loctite 222 thread locking compound to the bolts prior to fitting, allowing sufficient to fill all the engaged threads. Assemble components and tighten as necessary.

The parts may be disassembled by hand if required.

tcs manual page 31

Image 31
Contents TCS Series TCS series TCS series TCS series Unpacking the TCS series loudspeaker ThanksIntroduction FeaturesProduct Range Summary TCS series TCS series Amplifier considerations System RequirementsSystem Configurations TCS series LMS-D6 Loudspeaker Management System Loudspeaker Connections Cable Length Connecting CablesGeneral Flying and LiftingFlying single enclosures TCS series TCS series Installation of a single TCS series enclosure using eyebolts TCS series Flying multiple TCS-56/59 enclosures TCS series Rigging Instructions for a 2-wide TCS-56/59 array Rigging Instructions for a 3-wide TCS-56/59 array Rigging the TCS-40 with 3-wide TCS-56/59 arrays 12 LF, 1 HF TCS-20 TCS-30 TCS-35 TCS-40 TCS-56 TCS-59TCS-108SP Warranty Coverage Limited WarrantyShipping Limitation of implied warranties Incidental and consequential damagesUse of thread locking compounds Appendix CTCS series