Technical Data
Technical Data
Husky 2200 Diaphragm Pump |
|
|
|
|
| US | Metric | ||
Maximum fluid working pressure | 125 psi | 0.86 MPa, 8.6 bar | ||
Air pressure operating range | 20 to 125 psi | 0.14 to 0.86 MPa, 1.4 to 8.6 bar | ||
Air inlet size |
| 3/4 in. | npt(f) |
|
Air exhaust size |
| 1 in. | npt(f) |
|
Fluid inlet and outlet size (ANSI/DIN | 2 in | 50 mm | ||
flange) |
|
|
|
|
Maximum suction lift (reduced | Wet: | 31 ft | Wet: | 9.4 m |
if balls don’t seat well due to | Dry: | 16 ft | Dry: | 4.9 m |
damaged balls or seats, lightweight |
|
|
|
|
balls, or extreme speed of cycling) |
|
|
|
|
Maximum size pumpable solids | 1/4 in. | 6.3 mm | ||
Minimum ambient air temperature | 32° F | 0° C | ||
for operation and storage. |
|
|
|
|
NOTE: Exposure to extreme low |
|
|
|
|
temperatures may result in damage |
|
|
|
|
to plastic parts. |
|
|
|
|
|
|
|
|
|
Air consumption |
|
|
|
|
Standard diaphragms | 70 scfm at 70 psi; 100 gpm | 2.0 m3/min at 0.48 MPa, 4.8 | ||
|
|
| bar, 379 lpm | |
Overmolded diaphragms | 75 scfm at 70 psi, 100 gpm | 2.1 m3/min at 0.48 MPa, 4.8 | ||
|
|
| bar, 379 lpm | |
Maximum air consumption |
|
|
|
|
Standard diaphragms | 140 scfm | 4.0 m3/min | ||
Overmolded diaphragms | 157 scfm | 4.4 m3/min | ||
Noise (dBa) |
|
|
|
|
Sound power measured per | ||||
Sound Power | 95.2 at 70 psi and 50 cpm | 95.2 at 4.8 bar and 50 cpm | ||
| 101.8 at 100 psi and full flow | 101.8 at 7.0 bar and full flow | ||
Sound Pressure | 87.3 at 70 psi and 50 cpm | 87.3 at 4.8 bar and 50 cpm | ||
| 94.7 at 100 psi and full flow | 94.7 at 7.0 bar and full flow | ||
Fluid flow per cycle |
|
|
|
|
Standard diaphragms | 1.6 gallons | 6.1 liters | ||
Overmolded diaphragms | 1.3 gallons | 4.9 liters | ||
Maximum |
|
|
|
|
Standard diaphragms | 200 gpm | 757 lpm | ||
Overmolded diaphragms | 200 gpm | 757 lpm |
22 | 3A2578B |