Graco 3A2578B Technical Data, Husky 2200 Diaphragm Pump, Air consumption, Maximum air consumption

Page 22

Technical Data

Technical Data

Husky 2200 Diaphragm Pump

 

 

 

 

 

US

Metric

Maximum fluid working pressure

125 psi

0.86 MPa, 8.6 bar

Air pressure operating range

20 to 125 psi

0.14 to 0.86 MPa, 1.4 to 8.6 bar

Air inlet size

 

3/4 in.

npt(f)

 

Air exhaust size

 

1 in.

npt(f)

 

Fluid inlet and outlet size (ANSI/DIN

2 in

50 mm

flange)

 

 

 

 

Maximum suction lift (reduced

Wet:

31 ft

Wet:

9.4 m

if balls don’t seat well due to

Dry:

16 ft

Dry:

4.9 m

damaged balls or seats, lightweight

 

 

 

 

balls, or extreme speed of cycling)

 

 

 

 

Maximum size pumpable solids

1/4 in.

6.3 mm

Minimum ambient air temperature

32° F

0° C

for operation and storage.

 

 

 

 

NOTE: Exposure to extreme low

 

 

 

 

temperatures may result in damage

 

 

 

 

to plastic parts.

 

 

 

 

 

 

 

 

 

Air consumption

 

 

 

 

Standard diaphragms

70 scfm at 70 psi; 100 gpm

2.0 m3/min at 0.48 MPa, 4.8

 

 

 

bar, 379 lpm

Overmolded diaphragms

75 scfm at 70 psi, 100 gpm

2.1 m3/min at 0.48 MPa, 4.8

 

 

 

bar, 379 lpm

Maximum air consumption

 

 

 

 

Standard diaphragms

140 scfm

4.0 m3/min

Overmolded diaphragms

157 scfm

4.4 m3/min

Noise (dBa)

 

 

 

 

Sound power measured per ISO-9614–2. Sound pressure was tested 3.28 ft (1 m) from equipment.

Sound Power

95.2 at 70 psi and 50 cpm

95.2 at 4.8 bar and 50 cpm

 

101.8 at 100 psi and full flow

101.8 at 7.0 bar and full flow

Sound Pressure

87.3 at 70 psi and 50 cpm

87.3 at 4.8 bar and 50 cpm

 

94.7 at 100 psi and full flow

94.7 at 7.0 bar and full flow

Fluid flow per cycle

 

 

 

 

Standard diaphragms

1.6 gallons

6.1 liters

Overmolded diaphragms

1.3 gallons

4.9 liters

Maximum free-flow delivery

 

 

 

 

Standard diaphragms

200 gpm

757 lpm

Overmolded diaphragms

200 gpm

757 lpm

22

3A2578B

Image 22
Contents Operation Husky 2200 Air-OperatedDiaphragm Pump3A2578B Contents 3A2578BFIRE AND EXPLOSION HAZARD WarningsWarnings PRESSURIZED EQUIPMENT HAZARDEQUIPMENT MISUSE HAZARD PLASTIC PARTS CLEANING SOLVENT HAZARDWarnings THERMAL EXPANSION HAZARDBURN HAZARD WarningsTOXIC FLUID OR FUMES HAZARD PERSONAL PROTECTIVE EQUIPMENTRelated Manuals To Order Replacement PartsOrdering Information To Find Your Nearest DistributorP01A Configuration Number Matrix2200P 2200PTighten Fasteners InstallationGeneral Information Tips to Reduce CavitationSystem Components InstallationAccessories/Components Not Supplied 3A2578BAir Lines InstallationGround The System •Fluid supply container: Follow local codeInstallation Air Exhaust VentilationNOTICE To provide a remote exhaustInstallation Fluid Supply LineFluid Outlet Line 3A2578BInstallation Flange Connections3A2578B Operation Pressure Relief ProcedureStart and Adjust the Pump Flush the Pump Before First UseLubrication MaintenanceMaintenance Schedule Tighten Threaded ConnectionsDo not overtorque Torque InstructionsTorque Instructions Fluid Cover ScrewsNotes Notes3A2578B Dimensions DimensionsEnd Flange Models, Polypropylene and PVDF PolypropylenePolypropylene Center Flange Models, Polypropylene OnlyDimensions PolypropyleneFluid Pressure Performance ChartsBolt-throughDiaphragms Air ConsumptionHow to Read the Charts Overmolded DiaphragmsPerformance Charts Fluid PressureHusky 2200 Diaphragm Pump Technical DataTechnical Data Air consumptionMaximum pump speed Technical DataWeight Wetted PartsGraco Information Graco Standard Husky Pump Warranty