Graco 965124, 965129 important safety instructions Check Valve Adjustment

Page 12

Service

12.Slide priming plate (9) (beveled edge up) onto priming rod (8). Screw nut (10) onto priming rod and tighten.

13.Reconnect the pump’s ground wire to a true earth ground.

Check Valve Adjustment

This pump has an adjustable piston ball check.

To change the piston ball travel, loosen the locknut (4). Turn the piston valve housing (14) counterclockwise to increase and clockwise to decrease. Medium viscosity fluids should have a 3/16 in. (5 mm) ball travel.

Decreasing the ball travel minimizes surging at stroke changeover; however, too short of ball travel restricts the flow and slows down the pump.

12 309407

Image 12
Contents Instructions Parts List Low-pressure, medium volume pump used to transfer greaseImportant Safety instructions Table of Contents SymbolsFire and Explosion Hazard Equipment Misuse Hazard Installation GroundingMounting the Pump Typical Installation KeyMaintenance Pressure Relief ProcedureStartup and Adjustment OperationTroubleshooting Problem Cause Solution309407 Service Displacement Pump Repair DisassemblyReassembly Follow the Pressure Relief Procedure onCheck Valve Adjustment 309407 Parts Description Qty Dimensions Mounting Hole LayoutTechnical Data Sound Power LevelSound Pressure Level Graco Standard Warranty Graco InformationToll Free