Specifications

 

Volume

Model P221A

Up to 2.21 GPM

 

Discharge Pressure (Continuous)

Up to 2000 PSI

Discharge Pressure (Intermittent)

Up to 2320 PSI*

Inlet Pressure

- 4.35 to 140 PSI

RPM

Up to 1750 RPM

Plunger Diameter

18mm

Stroke

7.0mm

Temperature of Pumped Fluids

Up to 160oF

Inlet Ports

(2) 1/2" BSP

Discharge Ports

(2) 3/8" BSP

Shaft Rotation

Top of Pulley Towards Fluid End

Crankshaft Diameter

24mm

Key Width

8mm

Shaft Mounting

Right Side Facing Manifold

Weight

11 lbs. 11oz.

Crankcase Oil Capacity

7.5 fl.oz.

Extended Crankcase Oil Capacity

9.0 fl.oz.

Volumetric Efficiency @ 1750 RPM

0.96

Mechanical Efficiency @ 1750 RPM

0.85

Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.

NOTE:

In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crank- case and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence.

P221A HORSEPOWER REQUIREMENTS

RPM GPM 1000 PSI 1500 PSI 2000 PSI* 2320 PSI*

1150

1.4

1.0

1.5

2.0

2.3

1450

1.8

1.3

1.9

2.5

2.9

1750

2.2

1.5

2.3

3.0

3.5

*Intermittent duty only

SPECIAL NOTE:

The theoretical gallons per revolution (gal/rev) is 0.00126.

To find specific outputs at various RPM, use the formula: GPM = 0.00126 x RPM

HORSEPOWER RATINGS: The rating shown are the power

requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.

We recommend a 1.15 service factor be specified when selecting an electric motor as the power source. To compute specific pump horse power requirements, use the following formula:

HP = (GPM X PSI) / 1450

7

Image 7
Contents Series P200A Important Operating Conditions Installation InstructionsP217A Horsepower Requirements SpecificationsModel P217A Model P218A P218A Horsepower RequirementsModel P219A P219A Horsepower RequirementsModel P220A P220A Horsepower RequirementsModel P221A P221A Horsepower RequirementsExploded View P200A Series Partno Description QTY P200A Series Parts ListModel P223A P223A Horsepower RequirementsP200A Series Repair Kits P200A Series Torque SpecificationsPumpsystemmalfunction Repair Instructions P200A Series Reassembly sequence of the P200A series pump P200A Dimensions inches Giant Industries Limited Warranty