REPAIR INSTRUCTIONS - P200A SERIES
9.If the ceramic plunger pipe (16B) is damaged, remove the plunger bolt (16C).
Discard the old plunger pipe (16B) and copper gasket (16D), and clean the old locktite from the plunger bolt (16C) and plunger base (16A). Replace the plunger with the new one and locktite the plunger bolt and torque to 220
NOTE: If there are deposits of any kind (i.e., lime deposits) in the valve casing, be certain that the weep holes in the weep return ring (25) and valve casing (26) have not been plugged.
Reassembly sequence of the P200A series pump
1)If oil seals (19) were removed, replace with seal lip towards crankcase. Lubricate seals before replacing.
2)Replace seal case (20) with
3)Generously lubricate
4)Replace the six
For maintenance of the gear end of your pump contact Giant Industries or your local distributor. Phone:
NOTE: Contact Giant Industries for Service School Information. Phone:
14