Greenheck Fan 474118 Service, Warranty Maintenance Log, Coil Change Out Procedure

Page 12

Service

Coil Change Out Procedure

Coils can only be pulled out through the side of the plenum cabinet. Side panels which are nearest to the coil can be removed if the coil needs to be replaced. Size 020 ERS plenums only have a single coil and do not require coil removal clearances on both sides. If necessary, both coils can be removed through the same side of the plenum housing. This process would require the removal of an additional spacer panel that separates the two coils within the unit.

Cabinet

 

Minimum Clearance

Size

 

(inches)

 

020

 

114

 

030

 

74 (each side)

 

040

 

100 (each side)

 

060

 

132 (each side)

 

Service Doors

 

 

 

Coil Service

Coil

Coil

Coil Service

Clearance

Clearance

 

 

Warranty

Maintenance Log

Date___________________ Time______________ AM/PM

Notes:___________________________________________

_________________________________________________

_________________________________________________

_________________________________________________

_________________________________________________

Date___________________ Time______________ AM/PM

Notes:___________________________________________

_________________________________________________

_________________________________________________

_________________________________________________

_________________________________________________

Date___________________ Time______________ AM/PM

Notes:___________________________________________

_________________________________________________

_________________________________________________

_________________________________________________

_________________________________________________

Date___________________ Time______________ AM/PM

Notes:___________________________________________

_________________________________________________

_________________________________________________

_________________________________________________

_________________________________________________

Greenheck warrants this equipment to be free from defects in material and workmanship for a period of one year from the shipment date. Any units or parts which prove defective during the warranty period will be replaced at our option when returned to our factory, transportation prepaid. Motors are warranted by the motor manufacturer for a period of one year. Should motors furnished by Greenheck prove defective during this period, they should be returned to the nearest authorized motor service station. Greenheck will not be responsible for any removal or installation costs.

As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice.

Greenheck Catalog Vektor ERS-MD provides additional information describing the equipment, fan performance, available accessories, and specification data.

AMCA Publication 410-96, Safety Practices for Users and Installers of Industrial and Commercial Fans, provides additional safety information. This publication can be obtained from AMCA International, Inc. at: www.amca.org.

®

Phone: (715) 359-6171 • Fax: (715) 355-2399E-mail: gfcinfo@greenheck.com • Website: www.greenheck.com

12

474118 • Model VKERS-MD IOM, Rev. 1, April 2011

Copyright 2011 © Greenheck Fan Corp.

Image 12
Contents Installation, Operation and Maintenance Manual General Safety InformationInspection and Maintenance during Storage ReceivingUnpacking HandlingTable of Contents Unit IdentificationInstallation Unit Weights ERS Plenum Section OnlyCabinet Weight Size Height Lbs Top viewPlenum Service Clearances and Access Locations Installation Vektor Riser InstallationSet the Vektor fan bypass air plenum GasketingPlenum Side Inlet Duct Dimension Duct ConnectionsPlenum Bottom Inlet Opening Duct ConnectionsInstallation of Water Coil Piping Water Coil Installation RecommendationsDrain Trap Coils Filter Replacement Coil Installation Checklist External Pipe Connection Optional Accessories Vektor Field Coating Touch-up Procedure for Scratched AreasDirty Filter Sensor Magnehelic Gauge Vapor Tight LightsRoutine Maintenance Coil MaintenanceService Warranty Maintenance LogCoil Change Out Procedure Cabinet Minimum Clearance Size Inches