Ericsson LBI-39175A Setting Tracking Data, Situation NEW Tracking Data, Parameter Limit, Sinad

Page 10

LBI-39175A

SETTING TRACKING DATA

Normally, Tracking Data is set at the factory, and need not be re-loaded. However, the following repair situations require re-loading some or all of the Tracking Data:

SITUATION

NEW TRACKING DATA

 

 

Replace PA module

RF Power, Squelch (Check: Re-load if necessary.)

 

 

Replace TXRX module

RF Power, Modulation Deviation, Squelch, Feature

 

Encryption, and Data Offset

 

 

Replace Control Unit module

None

 

 

Replace Synthesizer PWB

Modulation Deviation and Data Offset

 

 

Replace Logic PWB

RF Power, Squelch, Modulation Deviation, Feature

 

Encryption, and Data Offset.

To re-load Tracking Data, connect the radio in the appropriate configuration as shown in Figures 2 and 3, and perform the following steps:

1.Using the PC Programming Software , make sure the radio is programmed in the following sequence:

Parameter

Limit

TX Modulation Deviation

 

30 kHz channel spacing

4.4 ±0.1 kHz

12.5 kHz channel spacing

2.25 ±0.1 kHz

a.Customer Operational Software (if necessary)

b.Tracking Data (First Iteration -- Tracking Data originally shipped with the radio is a good starting point.)

TX High Power

110 W Model

110 +4, -0 W

 

50 W Model

50

+2, -0 W

 

25 W Model

25

+0, -1 W

TX Mid Power

25 W Model

15

+.5, -.5 W

c.Feature Encryption File (if necessary). Note: In order to load an Encryption File into a new Logic PWB, After Market Services must first be contacted at 1-800-368-3277 for authorization code. Otherwise the file will not load.

d.Personality, which contains a Conventional System using the frequencies given in Tables 2 and 3.

2.Connect the radio unit in the normal operating configuration. Activate the radio unit, and, using a Service Monitor HP8920A or equivalent, measure the Transmitter Power, Modulation Deviation, and Squelch Threshold for each of the applicable frequencies given in Tables 2 and 3. Measurements should be within the following limits:

TX Low Power 110 W Model

55

+2, -0 W

50 W Model

25

+1, -0 W

25 W Model

6

+.5 -.5 W

RX Squelch Threshold

8

+1, -0 dB

 

SINAD

3.If measurements are within the limits, the job is complete. If the measurements are not within the limits stated, re-connect the Programming Maintenance Software "MRKMAINT." Display the Tracking Data screen. For those frequencies where measurements are not within the stated limits, enter new Tracking Data, following instructions on the screen. Program into the radio personality, and exit.

4.Repeat Steps 2 and 3 until the measurements at every frequency given in Tables 2 and 3 are within the limits specified.

10

Image 10
Contents Table of Contents LBI-39175ATransmitter DescriptionReceiver Maintenance Checks MaintenancePreventive Maintenance Maintenance Checks IntervalTransceiver Txrx Module Disassembly ProcedureTo Remove the Unit from the Mounting Bracket Control Unit Front MountedTo Re-Assemble Unit after Servicing Front Mount Control Unit O-Ring Lubrication Alignment Procedures IntroductionLBI-39175A Tracking Data Test FrequenciesParameter Limit Setting Tracking DataSituation NEW Tracking Data SinadTransmitter Alignment PA Transistor ReplacementTo Replace the PA RF Transistors Receiver Alignment Adjustment ProceduresTest Equipment Required Squelch Adjustment Troubleshooting GuideMicrophonics Serviceable Parts Diagnostic Procedures Typical Orion Test ConfigurationTransmitter Additional Tools RequiredPA PWB Receiver PWBControl Unit EGEAll System Groups Orion System Errors Error CodesGeneral NON-FATAL Errors Fatal ErrorsError Message Description ROM Fatal Systems Errors Operational Software Non-Fatal System ErrorsOperational Software Fatal System Errors Dacsnolock No LockRadio Programming Errors Message CodeEricsson Inc