SETTING TRACKING DATA
Normally, Tracking Data is set at the factory, and need not be
SITUATION | NEW TRACKING DATA |
|
|
Replace PA module | RF Power, Squelch (Check: |
|
|
Replace TXRX module | RF Power, Modulation Deviation, Squelch, Feature |
| Encryption, and Data Offset |
|
|
Replace Control Unit module | None |
|
|
Replace Synthesizer PWB | Modulation Deviation and Data Offset |
|
|
Replace Logic PWB | RF Power, Squelch, Modulation Deviation, Feature |
| Encryption, and Data Offset. |
To
1.Using the PC Programming Software , make sure the radio is programmed in the following sequence:
Parameter | Limit |
TX Modulation Deviation |
|
30 kHz channel spacing | 4.4 ±0.1 kHz |
12.5 kHz channel spacing | 2.25 ±0.1 kHz |
a.Customer Operational Software (if necessary)
b.Tracking Data (First Iteration
TX High Power | 110 W Model | 110 +4, | |
| 50 W Model | 50 | +2, |
| 25 W Model | 25 | +0, |
TX Mid Power | 25 W Model | 15 | +.5, |
c.Feature Encryption File (if necessary). Note: In order to load an Encryption File into a new Logic PWB, After Market Services must first be contacted at
d.Personality, which contains a Conventional System using the frequencies given in Tables 2 and 3.
2.Connect the radio unit in the normal operating configuration. Activate the radio unit, and, using a Service Monitor HP8920A or equivalent, measure the Transmitter Power, Modulation Deviation, and Squelch Threshold for each of the applicable frequencies given in Tables 2 and 3. Measurements should be within the following limits:
TX Low Power 110 W Model | 55 | +2, |
50 W Model | 25 | +1, |
25 W Model | 6 | +.5 |
RX Squelch Threshold | 8 | +1, |
| SINAD |
3.If measurements are within the limits, the job is complete. If the measurements are not within the limits stated,
4.Repeat Steps 2 and 3 until the measurements at every frequency given in Tables 2 and 3 are within the limits specified.
10