Ericsson LBI-39175A manual Operational Software Fatal System Errors, Dacsnolock No Lock

Page 22

LBI-39175A

Operational Software Fatal System Errors

ERROR NAME

MESSAGE

CODE

DESCRIPTION

 

 

 

 

RADC_PITD_ERROR

TRACKING

200

Personality tracking data error. Re-program the tracking data.

RADC_PIHW_ERROR

PERSDATA

201

Personality hardware data error. Re-program the personality.

RADC_FREQ_ERROR

FREQDATA

202

Personality frequency data error. Re-program the personality.

RADC_PITD_MALLOC_ERROR

SOFTWARE

203

Personality tracking data malloc error. Re-program the tracking data.

RADC_PITD_CKSUM_ERROR

SOFTWARE

204

Personality tracking data checksum error. Re-program the tracking data.

DACS_NO_LOCK

NO LOCK

300

Synthesizer did not lock or became unlocked. Check the frequencies in the PC

 

 

 

programmer and re-program the radio personality.

DACS_MODEM_FATAL_ERROR

SOFTWARE

301

Unable to correctly configure the modem for EDACS operation. Re-program

 

 

 

the personality.

DACS_RADC_FAILURE

SOFTWARE

302

Power cycle the radio.

DACS_MODEM_RXOVR

SOFTWARE

304

Hardware Modem overflow. Power cycle the radio.

DACS_MODEM_RXAVR

SOFTWARE

305

Power cycle the radio.

CONV_RADC_ERROR

SOFTWARE

400

Error calling RADC function. Power cycle the radio.

CONV_NOLOCK_ERROR

NO LOCK

401

Synthesizer became unlocked. check the frequencies in the PC programmer

 

 

 

and re-program the radio personality.

CONV_PUT_UIMSG_ERROR

SOFTWARE

402

UI message buffer not enabled. Power cycle the radio.

CONV_MODEM_RXOVR

SOFTWARE

403

Conventional DIGV modem overflow.

CONV_MODEM_RXAVR

SOFTWARE

404

Conventional DIGV modem underflow.

CONV_MODEM_FATAL_ERROR

SOFTWARE

405

Unable to correctly configure the modem for conventional DIGV operation.

CONV_PERS_ERROR

PERSDATA

407

Conventional personality error.

PI_NOPERS_ERROR

PERSDATA

500

Personality data is not present. Program the personality.

PI_CRC_ERROR

PERSDATA

501

Flash personality CRC did not match EEPROM. Re-program the personality.

PI_DESC_CRC_ERROR

PERSDATA

502

Crucial personality data has incorrect CRC. Re-program the personality.

PI_MALLOC_ERROR

SOFTWARE

503

Could not allocate memory to store crucial personality data.

UI_FATAL_DEVICE_ERROR

PERSDATA

600

Input/Output device error.

UI_FATAL_SWTO_

SOFTWARE

601

Software memory error.

MALLOC_ERROR

 

 

 

UI_FATAL_SWTO_MAX_ERROR

SOFTWARE

602

Software error, power cycle the radio.

UI_FATAL_WINDOW_MAX_

SOFTWARE

603

Too many open windows.

ERROR

 

 

 

UI_FATAL_WINDOW_MALLOC_

SOFTWARE

604

Software memory error.

ERROR

 

 

 

UI_FATAL_MESSAGE_INVPARM

SOFTWARE

605

Invalid parameter to UI_PUT_MESSAGE(). software error, report how error

 

 

 

was encountered.

UI_FATAL_RI_MSGBUF_FULL

SOFTWARE

606

UI Task message buffer full error. Software error, report how error was

 

 

 

encountered.

UI_FATAL_RISYS_MSGBUF_FULL

SOFTWARE

607

Radio Interface System (EDACS/CONV) task message buffer full.

UI_FATAL_CI_MSGBUF_FULL

SOFTWARE

608

CI Task message buffer full.

UI_FATAL_DEVICE_

PERSDATA

609

I/O device type (from personality) not supported.

NOTSUPPORTED

 

 

 

UI_FATAL_AUXIO_MALLOC_

SOFTWARE

610

Software memory error.

ERROR

 

 

 

UI_FATAL_NET_DEVICE_ERROR

SOFTWARE

611

Network I/O device error

UI_FATAL_INVALID_CUID

SOFTWARE

612

CU ID is invalid or CU not connected. Insure that CU ID is CUA and DUAL

 

 

 

is disabled in personality.

UI_FATAL_NO_TONE_DATA

SOFTWARE

613

No tone data is available in personality.

UI_FATAL_UII0_MSGBUF_FULL

SOFTWARE

614

UI I/0 BBOS message buffer full.

AEGIS_ADI_OVERFLOW

SOFTWARE

801

ADI Transmit event not serviced in time and buffer has overflown.

AEGIS_RXBUF_MALLOC_ERROR

SOFTWARE

802

No memory available.

AEGIS_KEYLOAD_MALLOC_

SOFTWARE

803

No Keyloader table memory available.

ERROR

 

 

 

AEGIS_KEYLOAD_ERROR

SOFTWARE

804

General Keyload error has occurred.

AEGIS_DATAMEM_MALLOC_

SOFTWARE

805

No memory is allocated for data.

ERROR

 

 

 

AEGIS_KEYLOAD_NOTABL

SOFTWARE

806

No key table was found in EEPROM.

22

Image 22
Contents Table of Contents LBI-39175ATransmitter DescriptionReceiver Maintenance Checks MaintenancePreventive Maintenance Maintenance Checks IntervalTransceiver Txrx Module Disassembly ProcedureTo Remove the Unit from the Mounting Bracket Control Unit Front MountedTo Re-Assemble Unit after Servicing Front Mount Control Unit O-Ring Lubrication Alignment Procedures IntroductionLBI-39175A Tracking Data Test FrequenciesParameter Limit Setting Tracking DataSituation NEW Tracking Data SinadTransmitter Alignment PA Transistor ReplacementTo Replace the PA RF Transistors Receiver Alignment Adjustment ProceduresTest Equipment Required Squelch Adjustment Troubleshooting GuideMicrophonics Serviceable Parts Diagnostic Procedures Typical Orion Test ConfigurationTransmitter Additional Tools RequiredPA PWB Receiver PWBControl Unit EGEAll System Groups Orion System Errors Error CodesGeneral NON-FATAL Errors Fatal ErrorsError Message Description ROM Fatal Systems Errors Operational Software Non-Fatal System ErrorsOperational Software Fatal System Errors Dacsnolock No LockRadio Programming Errors Message CodeEricsson Inc