SYMPTOM

 

DIAGNOSTIC PROCEDURE

 

 

 

Radio dead at power-on

a.

Check the battery connections and the Red lead A+ fuse on the power

(display dark and no

 

cable.

 

 

lighted indicators)

b.

Turn the unit "OFF," then simultaneously press and hold the

 

 

 

"EMERGENCY" and "OPTION" buttons, while turning the unit "ON."

 

 

All indicator lights and all display dots should light. Release the buttons

 

 

and the display should show the following message:

 

 

© - 1993

or

© - 1994

 

 

EGE

 

EGE

 

 

This indicates the Control Unit is functioning correctly. If this passes,

 

 

check programming and feature encryption, using "EDACS3" PC

 

 

Programming utility.

 

 

 

c.

If this fails, measure A+ voltage at MIC connector Pin 6 (referenced to

 

 

ground at Pin 7). If this fails, check fuse F601 on the Logic PWB for A+

 

 

on each side of the part. Replace the PWB if it is open circuited.

 

d.

If the fuse is OK, check the connection of the Flex Circuit PC2 with J701

 

 

on the Logic PWB. If this fails, reconnect PC2, making sure the side tabs

 

 

are locked. Re-check the MIC connector Pin 6 for A+.

 

e.

If this passes, check the programming and feature encryption, using

 

 

"EDACS3" PC Programming utility. If this symptom persists, substitute a

 

 

known good Logic PWB, and re-program.

 

 

f.

If no A+ is present at MIC Pin 7, check for A+ on the Logic PWB J704 Pin

 

 

3. If this fails, check the J704/J1004 connection. If this fails, replace the

 

 

PA module. If this passes, replace the Logic PWB.

 

 

 

The Display lights, then

a.

Turn the unit "OFF," then simultaneously press and hold the

goes dead.

 

"EMERGENCY" and "OPTION" buttons, while turning the unit "ON."

 

 

All the indicator lights and all display dots should light. Release the buttons

 

 

and the display should show the following message:

 

 

© - 1993

or

© - 1994

 

 

EGE

 

EGE

 

 

This indicates the Control Unit is functioning correctly. If this passes,

 

 

check programming and feature encryption, using "EDACS3" PC

 

 

Programming utility.

 

 

 

b.

If this passes, check the connection of the Flex Circuit PC2 with J701 on

 

 

the Logic PWB. If this passes re-connect it making sure the side tabs are

 

 

locked.

 

 

 

 

 

 

 

18

Image 18
Contents Table of Contents LBI-39175ADescription TransmitterReceiver Maintenance Checks MaintenancePreventive Maintenance Maintenance Checks IntervalTransceiver Txrx Module Disassembly ProcedureTo Remove the Unit from the Mounting Bracket Control Unit Front MountedTo Re-Assemble Unit after Servicing Front Mount Control Unit O-Ring Lubrication Alignment Procedures IntroductionLBI-39175A Tracking Data Test FrequenciesParameter Limit Setting Tracking DataSituation NEW Tracking Data SinadPA Transistor Replacement Transmitter AlignmentTo Replace the PA RF Transistors Adjustment Procedures Receiver AlignmentTest Equipment Required Troubleshooting Guide Squelch AdjustmentMicrophonics Serviceable Parts Diagnostic Procedures Typical Orion Test ConfigurationAdditional Tools Required TransmitterPA PWB Receiver PWBControl Unit EGEError Codes All System Groups Orion System ErrorsGeneral Fatal Errors NON-FATAL ErrorsError Message Description ROM Fatal Systems Errors Operational Software Non-Fatal System ErrorsOperational Software Fatal System Errors Dacsnolock No LockRadio Programming Errors Message CodeEricsson Inc