La Crosse Technology WS-1510-IT LCD Screen, Manual Setting, LCD Contrast Setting

Page 3
Minutes flashing

SET key

Press and hold to enter manual setting modes: LCD contrast,

 

Manual time setting, 12/24 hour time display, Calendar setting, ºF/

 

ºC temperature unit, Wind speed unit, Rainfall unit, Pressure unit,

 

Relative pressure reference setting, Weather tendency threshold

 

setting, Storm warning threshold setting and Storm Alarm On/ Off

 

setting

Press to toggle between the display of Mode 1 or Mode 2:

 

Mode 1: "Wind speed + outdoor temp + rel. pressure"

 

Mode 2: "Gust + Dew Point temp + rainfall"

 

(Mode 2 displayed will be shown for 30 seconds. Then it will

The LCD screen is split into 5 sections displaying the following information:

1.Time and date/ indoor temp/ second

2.Wind data

3.Outdoor temperature, Dew point and humidity,

4.Air pressure, Rainfall data,

5.Air pressure history and Weather forecast icon.

Low battery Indicator

Time alarm icon

(weather center)

 

return to normal display automatically.)

In normal display mode, press and hold to switch on/ off the

 

Buzzer

In the weather alarm setting mode, press and hold to adjust

 

different alarm value and switch the alarm On/ Off

Press to activate the reset mode when max or min record is

 

shown

Stop the alarm during the time alarm or weather alarm ringing

+ key

In display Mode 1, press to toggle between the display of Preset alarm time, date, weekday + date, Indoor temp, or second in the time display

In display mode 2, press to toggle between the display of Rel. Pressure, 24 hour rainfall and Total rainfall

Press to adjust (increase) the level of different settings

Stop the alarm during the time alarm or weather alarm ringing

Press to confirm to reset the max/min record

HISTORY key

Press to display the weather data history records

Stop the alarm during the time alarm or weather alarm ringing

Press to exit manual setting mode and alarm setting mode

ALARM key

Press to enter the time alarm and weather alarm setting mode

Confirm particular alarm setting

Time display

Wind Chill

in °F or °

C

Outdoor temperature

or dew point

in °F or ºC

Outdoor temp.

alarm icon

Relative air pressure

display in inHg or

hPa, or total and 24h

rainfall display in inch

Air pressure

histogram

Calendar display

Buzzer off indicator

Wind direction

display and wind

speed in Beaufort

scale

Wind speed Hi

alarm icon

Wind speed or

gust in mph, km/h

Outdoor relative

humidity in %

Outdoor Humidity

alarm icon

Transmitter signal

reception icon

Weather tendency

indicator

Weather forecast

icon

Press to exit the manual setting mode

Stop the alarm during the time alarm or weather alarm ringing

Press to exit max/ min record display mode

MIN/MAX key

Press to display minimum and maximum records of various weather data

Press to adjust (decrease) the level of different settings

Stop the alarm during the time alarm or weather alarm ringing

LCD SCREEN

9

*In normal display user may press the SET key shortly to toggle between Mode 1 and Mode 2 display:

Mode 1 : Wind speed, outdoor temperature and relative pressure

reading are shown.

 

 

Wind speed icon

 

 

 

 

 

Outdoor temp

 

 

 

 

In Mode 1, this reception

 

 

 

 

icon

 

 

 

 

 

 

 

 

icon is showing the

 

 

 

 

 

condition of the

 

 

 

Rel Pressure

 

 

 

 

reception of the signal

 

 

 

from Thermo-hygro

icon

 

 

 

 

 

 

 

transmitter

 

 

 

 

 

 

 

 

 

 

 

Mode 2 : Wind Gust, Dew Point temperature and 24 Hour and Total Rainfall reading are shown.

Dew point icon

 

 

 

 

Wind gust icon

 

 

 

 

In Mode 2, this

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

reception icon is

Rainfall icon

 

 

 

showing the condition

 

 

 

 

 

of the reception of the

 

 

 

 

 

 

 

 

 

 

signal from Rain

 

 

 

 

 

sensor

 

 

 

 

 

 

MANUAL SETTING:

The following manual settings can be changed once the SET key is pressed and hold for about 3 seconds:

LCD contrast setting

Manual time setting

12/24 hour time display

Calendar setting

°F/ °C temperature unit setting

Wind speed unit

Rainfall unit setting

Air pressure unit setting

Relative pressure reference value setting

Weather tendency threshold value

Storm warning threshold value

Alarm On/ Off setting

LCD CONTRAST SETTING

Flashing

11

Low battery Indicator (Thermo-hygro) Low battery Indicator (rain sensor)

*When the signal from the transmitter/ or Rain sensor is successfully received by the Weather Station, this icon will be switched on. (If not successful, the icon will not be shown on the LCD). User can therefore easily see whether the last reception was successful (“ON” icon) or not (“OFF” icon). On the other hand, the short blinking of the icon shows that a reception is being done at that time.

10

The LCD contrast can be set within 8 levels, from "LCD 1" to "LCD 8" (default setting is LCD 5):

1.Press the SET key, the contrast level digit will start flashing.

2.Use the + or MIN/MAX key to adjust the level of contrast.

3.Confirm with the SET key and enter the MANUAL TIME SETTING.

MANUAL TIME SETTING:

You then may manually set the time of the clock by following the steps below:

Hour flashing

1.The hour digit will start flashing.

2.Use the + or MIN/MAX key to set the hour.

3.Press the SET key to switch to the minutes. The minute digit will start flashing.

4.Use the + or MIN/MAX key to set the minute.

5.Confirm the time with the SET key and enter the 12/24 HOUR TIME DISPLAY SETTING.

12/24 HOUR TIME DISPLAY SETTING:

Digit flashing

The time can be set to view as 12-hour or 24-hour format. The default time-display mode is 12-h. To set to 24-htime display:

1.Use the + or MIN/MAX key to toggle the value.

2. Confirm with the SET key and enter the CALENDAR SETTING.

CALENDAR SETTING:

"Date. Month." (for 24h time display) "Month. Date." (for 12h time display)

Année

The date default of the Weather Center is 1. 1. of year 2005. The date can be set manually by proceeding as follows.

1.The year digit starts flashing.

2.Use the + or MIN/MAX key to set the year. The range runs from "00" (2000) to "99" (2099).

3.Press the SET key to confirm the year and enter the month setting. The month digit will start flashing.

12

Image 3
Contents Table of Contents FeaturesSetting UP Function Keys Battery Change12/24 Hour Time Display Setting Manual SettingLCD Contrast Setting Manual Time SettingRelative AIR Pressure Unit Setting Temperature Unit SettingWind Speed Unit Setting Rainfall Unit SettingHysteresis High and LOW Outdoor Temperature Alarm SettingWind Speed Alarm Setting High and LOW Outdoor Humidity Alarm SettingWind Direction and Wind Speed Measurement Weather Tendency IndicatorRainfall Measurement Viewing the History DataTotal rainfall amount Reset the Maximum and Minimum Weather DataMaximum Gust with the date and time of recording Maximum wind speed with the date and time of recordingLOW Battery Indicator Switching ON/OFF the BuzzerPositioning LA Crosse Technology Sensor Extension Cable Care and MaintenanceSpecifications Warranty InformationProper Restart Quick Set-up Guide FAQ WS-1510-ITProgram Set Up Menu Mounting SensorsOutdoor Temperature/Humidity is Inaccurate 12/24-HOUR Time ModeIndoor Temperature Readings Display Indoor Temperature is BlankReset Total Rainfall Turning off the Time AlarmStorm Alarm Reset the Min/Max dataDisplay Information Entire Display is Blank Power Source Battery LeakageForecast Icons Forecast Icon Shows Incorrect Conditions Forecast Icon is Blinking