SET key
• | Press and hold to enter manual setting modes: LCD contrast, |
| Manual time setting, 12/24 hour time display, Calendar setting, ºF/ |
| ºC temperature unit, Wind speed unit, Rainfall unit, Pressure unit, |
| Relative pressure reference setting, Weather tendency threshold |
| setting, Storm warning threshold setting and Storm Alarm On/ Off |
| setting |
• | Press to toggle between the display of Mode 1 or Mode 2: |
| Mode 1: "Wind speed + outdoor temp + rel. pressure" |
| Mode 2: "Gust + Dew Point temp + rainfall" |
| (Mode 2 displayed will be shown for 30 seconds. Then it will |
The LCD screen is split into 5 sections displaying the following information:
1.Time and date/ indoor temp/ second
2.Wind data
3.Outdoor temperature, Dew point and humidity,
4.Air pressure, Rainfall data,
5.Air pressure history and Weather forecast icon.
Low battery Indicator | Time alarm icon |
(weather center) |
| return to normal display automatically.) |
• | In normal display mode, press and hold to switch on/ off the |
| Buzzer |
• | In the weather alarm setting mode, press and hold to adjust |
| different alarm value and switch the alarm On/ Off |
• | Press to activate the reset mode when max or min record is |
| shown |
• | Stop the alarm during the time alarm or weather alarm ringing |
+ key
•In display Mode 1, press to toggle between the display of Preset alarm time, date, weekday + date, Indoor temp, or second in the time display
•In display mode 2, press to toggle between the display of Rel. Pressure, 24 hour rainfall and Total rainfall
•Press to adjust (increase) the level of different settings
•Stop the alarm during the time alarm or weather alarm ringing
•Press to confirm to reset the max/min record
HISTORY key
•Press to display the weather data history records
•Stop the alarm during the time alarm or weather alarm ringing
•Press to exit manual setting mode and alarm setting mode
ALARM key
• | Press to enter the time alarm and weather alarm setting mode |
• | Confirm particular alarm setting |
Time display |
Wind Chill |
in °F or ° |
C |
Outdoor temperature |
or dew point |
in °F or ºC |
Outdoor temp. |
alarm icon |
Relative air pressure |
display in inHg or |
hPa, or total and 24h |
rainfall display in inch |
Air pressure |
histogram |
Calendar display |
Buzzer off indicator |
Wind direction |
display and wind |
speed in Beaufort |
scale |
Wind speed Hi |
alarm icon |
Wind speed or |
gust in mph, km/h |
Outdoor relative |
humidity in % |
Outdoor Humidity |
alarm icon |
Transmitter signal |
reception icon |
Weather tendency |
indicator |
Weather forecast |
icon |
• | Press to exit the manual setting mode |
• | Stop the alarm during the time alarm or weather alarm ringing |
• | Press to exit max/ min record display mode |
MIN/MAX key
•Press to display minimum and maximum records of various weather data
•Press to adjust (decrease) the level of different settings
•Stop the alarm during the time alarm or weather alarm ringing
LCD SCREEN
9
*In normal display user may press the SET key shortly to toggle between Mode 1 and Mode 2 display:
Mode 1 : Wind speed, outdoor temperature and relative pressure | |||||
reading are shown. |
|
| Wind speed icon | ||
|
|
|
|
| |
Outdoor temp |
|
|
|
| In Mode 1, this reception |
|
|
|
| ||
icon |
|
|
| ||
|
|
|
|
| icon is showing the |
|
|
|
|
| condition of the |
|
|
| |||
Rel Pressure |
|
|
|
| reception of the signal |
|
|
| from | ||
icon |
|
|
|
| |
|
|
| transmitter | ||
|
|
|
|
| |
|
|
|
|
|
|
Mode 2 : Wind Gust, Dew Point temperature and 24 Hour and Total Rainfall reading are shown.
Dew point icon |
|
|
|
| Wind gust icon |
|
|
|
| In Mode 2, this | |
|
|
| |||
|
|
|
| ||
|
|
|
|
| |
|
|
|
|
| reception icon is |
Rainfall icon |
|
|
| showing the condition | |
|
| ||||
|
|
| of the reception of the | ||
|
|
|
|
| |
|
|
|
|
| signal from Rain |
|
|
|
|
| sensor |
|
|
|
|
|
|
MANUAL SETTING:
The following manual settings can be changed once the SET key is pressed and hold for about 3 seconds:
•LCD contrast setting
•Manual time setting
•12/24 hour time display
•Calendar setting
•°F/ °C temperature unit setting
•Wind speed unit
•Rainfall unit setting
•Air pressure unit setting
•Relative pressure reference value setting
•Weather tendency threshold value
•Storm warning threshold value
•Alarm On/ Off setting
LCD CONTRAST SETTING
Flashing
11
Low battery Indicator
*When the signal from the transmitter/ or Rain sensor is successfully received by the Weather Station, this icon will be switched on. (If not successful, the icon will not be shown on the LCD). User can therefore easily see whether the last reception was successful (“ON” icon) or not (“OFF” icon). On the other hand, the short blinking of the icon shows that a reception is being done at that time.
10
The LCD contrast can be set within 8 levels, from "LCD 1" to "LCD 8" (default setting is LCD 5):
1.Press the SET key, the contrast level digit will start flashing.
2.Use the + or MIN/MAX key to adjust the level of contrast.
3.Confirm with the SET key and enter the MANUAL TIME SETTING.
MANUAL TIME SETTING:
You then may manually set the time of the clock by following the steps below:
Hour flashing
1.The hour digit will start flashing.
2.Use the + or MIN/MAX key to set the hour.
3.Press the SET key to switch to the minutes. The minute digit will start flashing.
4.Use the + or MIN/MAX key to set the minute.
5.Confirm the time with the SET key and enter the 12/24 HOUR TIME DISPLAY SETTING.
12/24 HOUR TIME DISPLAY SETTING:
Digit flashing
The time can be set to view as
1.Use the + or MIN/MAX key to toggle the value.
2. Confirm with the SET key and enter the CALENDAR SETTING.
CALENDAR SETTING:
"Date. Month." (for 24h time display) "Month. Date." (for 12h time display)
Année
The date default of the Weather Center is 1. 1. of year 2005. The date can be set manually by proceeding as follows.
1.The year digit starts flashing.
2.Use the + or MIN/MAX key to set the year. The range runs from "00" (2000) to "99" (2099).
3.Press the SET key to confirm the year and enter the month setting. The month digit will start flashing.
12