Center will be more accurate compared to use in areas where the weather is stagnant most of the time (for example mostly sunny).

If the Weather Center is moved to another location significantly higher or lower than its initial standing point (for example from the ground floor to the upper floors of a house), discard the weather forecast for the next 48-60 hours, as the Weather Center may mistake the new location as being a possible change in air-pressure when really it is due to the slight change of altitude.

WEATHER TENDENCY INDICATOR

Working together with the weather icons is the weather tendency indicators (arrow located on the left and right sides of the weather icons). When the indicator points upwards, it means that the air- pressure is increasing and the weather is expected to improve, but when indicator points downwards, the air-pressure is dropping and the weather is expected to become worse.

Taking this into account, one can see how the weather has changed and is expected to change. For example, if the indicator is pointing downwards together with cloud and sun icons, then the last noticeable change in the weather was when it was sunny (the sun icon only). Therefore, the next change in the weather will be cloud with rain icons since the indicator is pointing downwards.

Note:

Once the weather tendency indicator has registered a change in air pressure, it will remain permanently visualized on the LCD.

AIR PRESSURE HISTORY (ELECTRONIC BAROMETER WITH BAROMETRIC PRESSURE TREND)

The bottom section of the LCD also shows the relative air pressure value and the air pressure history.

Depending on programming conditions, display of the history of air pressure is in the form of a graph consisting of vertical bars.

The bar graph of the electronic barometer shows the air pressure history of the past 12 hours in five 3-hour steps.

Air pressure

 

 

 

 

 

 

 

 

 

 

 

Air pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

changes in inHg

 

 

 

 

 

 

 

 

 

 

 

changes in hPa

 

 

 

 

 

 

 

 

 

 

 

The horizontal axis represents the last 12 hours air pressure recording (-12, -9, -6, -3 and 0 hour). The bars are plotted at each of the 5 steps and give the trend over the recorded period. The scale on the right

21

RAINFALL MEASUREMENT

The total rainfall and 24 hour rainfall measurement is displayed in the fourth section of the LCD, in the unit of mm or inch.

To View the 24-hour rainfall or the Total rainfall reading:

1.In normal display, press SET key once and the display will shift to Mode 2.

2.Press + key consecutively key to toggle between the 24-hour rainfall, Total rainfall and Rel. pressure reading.

24 hour

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

rainfall icon

 

 

 

 

 

 

24 hour rainfall

 

 

 

 

 

 

 

 

amount

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Total

 

 

 

 

 

 

 

 

rainfall

 

 

 

 

 

 

 

Total rainfall

icon

 

 

 

 

 

 

 

 

 

 

 

 

 

 

amount

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIEWING THE HISTORY DATA

The weather station can store up to 140 sets of weather data which are recorded automatically at 3-hour intervals after the weather station is powered up, at the nearest time of 0:00, 03:00, 06:00, 09:00, 12:00, 15:00, 18:00 and 21:00. For instance, if user has manually set the time as 14:52 after installing batteries, the first history record will be made at the coming 15:00 automatically. Then the second record will be on 18:00 and so on.

Each weather record includes the Wind direction, Wind speed/ gust in Beaufort scale, Wind chill temperature, wind speed/gust, dew point, Outdoor temp and humidity, relative pressure, 24-hour rainfall and total rainfall, pressure history and weather tendency. Also, the time and date of recording will be displayed.

Note:

In order to acquire the correct time of recording of the history records, you shall manually set the current time as soon as installing batteries to the weather station. Afterwards, you should avoid changing the pre-set time as it will also alter the recorded "time of recording" of each history record, which may lead to confusion.

To view the weather history:

1.In normal display, press the HISTORY key. The latest weather record will be shown with the date and time of recording. The "HISTORY" icon will be displayed at the bottom of the LCD.

2.When viewing History records, user may shift to see the Mode 1 or Mode 2 data by pressing the SET key.

(Mode 1: with wind speed + outdoor Temp + Rel. pressure;

Mode 2 : with wind gust + Dew point + rainfall data)

23

compares the result. The "0" in the middle of this scale determines the current air pressure.

The vertical axis represents the air pressure changes in inHg (+0.12, +0.06, 0, -0.06, -0.12. The “0” represents the current air pressure). The newly measured pressure was compared to the previously recorded pressure reading. The pressure change is expressed by the difference between the current ("0h") and the past readings in division of ±2 hPa or ±0.06 inHg. If the bars are rising, this indicates that the weather is getting better due to an increase in air pressure. If the bars go down it indicates a drop of the air pressure and the weather is expected to get worse from the present time "0".

At every full hour, the current air pressure is used as a basis for the display of a new graph bar. The existing graph is then moved one column to the left.

Note:

For accurate barometric pressure trend, the Weather Center should operate at the same altitude. For example, it should not be moved. Should the unit be moved, for instance from the ground to the second floor of the house, the readings for the next 48-60 hours shall be discarded.

Note:

The bar graph will scroll right to light regularly to prevent LCD burnout.

WIND DIRECTION AND WIND SPEED MEASUREMENT

In normal display mode, the second section of the LCD shows the following wind data.

Wind direction (shown on the a compass scale of 16 divisions) and wind speed/ gust in Beaufort scale

Wind chill in °F or °C

Wind Speed in km/h, mph or m/s

Gust in km/h, mph or m/s (displayed when in Mode 2, by pressing the SET key shortly)

Text showing wind speed in Beaufort scale

 

 

 

Pointer indicates the

 

 

 

currently detected wind

 

 

 

direction

 

 

 

 

This alarm symbol

 

 

 

 

 

 

 

 

indicates that the alarm

 

 

 

 

is set On

 

 

Wind speed or gust will be show

 

 

 

 

Wind chill

 

 

 

22

Note: If user wants to choose to view total rainfall or 24-hour rainfall in history records, he shall first in normal display choose to show the particular rainfall data, the press History key and SET key to view the particular rainfall data in History records.

HISTORY icon

3.When viewing History records, press MIN/ MAX to view older records.

(Press MIN/MAX and + key to view "Previous" and "Next" record respectively. The records are made at 3-hour intervals)

Note:

The stored history records will not be retained after battery change or whenever battery is removed.

The total rainfall value will be exhibited in whole number (no decimal place) in the history record.

VIEWING THE MAXIMUM/ MINIMUM WEATHER DATA

The weather station will record the maximum and minimum value of the various weather data with time and date of recording automatically. The following stored maximum and minimum weather data can be viewed by pressing the MIN/MAX key in normal display mode.

1.Min outdoor temperature with the date and time of recording

Time and date of recording

MIN outdoor temperature

value

24

Image 6
Contents Table of Contents FeaturesSetting UP Battery Change Function KeysManual Time Setting Manual SettingLCD Contrast Setting 12/24 Hour Time Display SettingRainfall Unit Setting Temperature Unit SettingWind Speed Unit Setting Relative AIR Pressure Unit SettingHigh and LOW Outdoor Humidity Alarm Setting High and LOW Outdoor Temperature Alarm SettingWind Speed Alarm Setting HysteresisViewing the History Data Weather Tendency IndicatorRainfall Measurement Wind Direction and Wind Speed MeasurementMaximum wind speed with the date and time of recording Reset the Maximum and Minimum Weather DataMaximum Gust with the date and time of recording Total rainfall amountLOW Battery Indicator Switching ON/OFF the BuzzerPositioning Warranty Information Care and MaintenanceSpecifications LA Crosse Technology Sensor Extension CableMounting Sensors FAQ WS-1510-ITProgram Set Up Menu Proper Restart Quick Set-up GuideIndoor Temperature is Blank 12/24-HOUR Time ModeIndoor Temperature Readings Display Outdoor Temperature/Humidity is InaccurateReset the Min/Max data Turning off the Time AlarmStorm Alarm Reset Total RainfallForecast Icon is Blinking Power Source Battery LeakageForecast Icons Forecast Icon Shows Incorrect Conditions Display Information Entire Display is Blank