La Crosse Technology WS-9046U To view the current rainfall measurements, Time Alarm

Page 14

Rainfall 1 hour icon

Rainfall volume reading

Rainfall volume unit

Rainfall 24 hour icon

Total Rainfall icon

`

To view the current rainfall measurements:

Press and release the WIND/RAIN/SNZ button to toggle between GUST, WIND CHILL, 1 hour rainfall volume, 24 hour rainfall volume and total rainfall volume.

To view the maximum rainfall measurements:

1.Press the WIND/RAIN/SNZ button and hold for 3 seconds to enter MAX WIND MODE.

2.Press the WIND/RAIN/SNZ button 4 times to 6 times to view the Max 1 hour rainfall, Max 24 hour rainfall and Max total rainfall respectively.

Note:

1.

The Max 1 hour rainfall is maximum value among all the all 1hour rainfall readings

 

 

measured.

 

2.

The Max 24 hour rainfall is maximum value among all the all 24hour rainfall readings

 

 

measured.

 

3.

The Max total rainfall is accumulated rainfall volume from the commencement of

 

 

measurement, which is equivalent to the Max rainfall shown in the current rainfall

 

 

mode.

To reset the maximum rainfall measurements:

1.Press the WIND/RAIN/SNZ button and hold for 3 seconds to enter MAX WIND MODE.

2.Press the WIND/RAIN/SNZ button for times to select the max rainfall data to be reset.

3.Press and hold the SET button for 5 seconds to reset the MAX Rainfall data to zero value. The time of record will be reset to the current time.

To return to the normal viewing mode:

1.Press and release the ALM/+ button or

2.After 15 seconds the display will automatically return to the normal viewing mode.

X.TIME ALARM

To set the time alarm:

1.Press and hold the ALM/+ button for 5 seconds.

2.The alarm time will begin to flash in the DATE LCD.

3.Press and release the IN/HR button to adjust the hour.

13

Image 14
Contents WS-9046U Table of Contents Inventory of Contents Optional Sensor Purchase SeperatelyQuick SET-UP Guide Additional Equipment not includedAbout Wwvb Radio Controlled Time Important Notes on Set-up and OperationProgram Mode Detailed SET-UP Guide Battery InstallationRemote TEMPERATURE/HUMIDITY Programming Sequence and Default SettingsDaylight Saving Time DST Setting III. Setting the LCD ContrastIV. Time Zone Setting II. Function KeysManual Time Setting VIII. Time SettingWwvb Remote Control Time IX. Setting the YEAR, DAY and MonthXiii Setting the Forecast Sensitivity Setting the SnoozeSetting the Unit of Rainfall inch/ mm Selecting F or CWeather Icons Features of the WS-9046UWeather Forecast Viewing the Indoor Temperature Records III. Outdoor Temperature and HumidityIV. Minimum and Maximum Temperature Records Viewing the Outdoor Temperature RecordsMoon Phase VI. Viewing the CURRENT, Maximum and Minumum DEW PointVIII. Beaufort Scale Wind Speed Fort Number Or Force Wind Speed Mph Km/hr KnotsIX. Rainfall Measurement Time Alarm To reset the maximum rainfall measurementsTo return to the normal viewing mode To view the current rainfall measurementsMounting with Adhesive Tape Mounting Remote TEMPERATURE/HUMIDITY SensorMounting with Screws Mounting with Nylon StrapsIII. the Rain Sensor Optional II. the Remote Wind Speed SensorMounting with the U-SHAPED Bolt III. the Indoor Weather Station TroubleshootingMaintenance and Care Instructions Dimensions H x W x D SpecificationsPower Supply Weather data measuring rangeFCC Disclaimer