HEAT PUMP SPECIFICATIONS
GSH130[36-60]3* GSH130[48-60]4*
| GSH130363AE | GSH130363AF | GSH130483AE | GSH130603AC | GSH130484AC | GSH130604AC |
|
|
|
|
|
|
|
Cooling Capacity, BTUH | 35,000 | 31,400 | 45,000 | 55,500 | 45,000 | 55,500 |
|
|
|
|
|
|
|
Compressor |
|
|
|
|
|
|
R.L. Amps | 9.0 | 9.9 | 12.4 | 17.3 | 5.8 | 6.7 |
L.R. Amps | 65.5 | 73.0 | 88.0 | 123.0 | 44.0 | 49.5 |
Loss of Charge Pressure Switch |
|
|
|
|
|
|
Open / Close | 7 PSIG/25 PSIG | 7 PSIG/25 PSIG | 7 PSIG/25 PSIG | 7 PSIG/25 PSIG | 7 PSIG/25 PSIG | 7 PSIG/25 PSIG |
|
|
|
|
|
|
|
Condenser Fan Motor |
|
|
|
|
|
|
Horsepower | 1/4 | 1/4 | 1/4 | 1/6 | 1/4 | 1/6 |
F.L. Amps | 1.5 | 1.5 | 1.5 | 1.1 | 0.8 | 0.6 |
|
|
|
|
|
|
|
Liquid Line, Inches O.D. | 3/8" | 3/8" | 3/8" | 3/8" | 3/8" | 3/8" |
Suction Line, Inches O.D. | 7/8" | 7/8" | 7/8" | 7/8" | 7/8" | 7/8" |
Refrigerant Charge | 188 | 188 | 223 | 233 | 223 | 233 |
|
|
|
|
|
|
|
Power Supply | ||||||
Minimum Circuit Ampacity(1) | 12.7 | 13.9 | 17.1 | 22.7 | 8.0 | 9.0 |
Maximum Overcurrent Device(2) | 20 | 20 | 20 | 40 | 15 | 15 |
Electrical Conduit Size |
|
|
|
|
|
|
Power Supply (Inches) | 1/2 or 3/4 | 1/2 or 3/4 | 1/2 or 3/4 | 1/2 or 3/4 | 1/2 or 3/4 | 1/2 or 3/4 |
Approximate Shipping Weight | 207 | 207 | 225 | 266 | 225 | 266 |
|
|
|
|
|
|
|
(1)Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
(2)Maximum Overcurrent Protection: Must use fuses or
NOTES:
*Always check the S&R plate for electrical data on the unit being installed.
*Installer will need to supply 7/8" to 1 1/8" adapters for suction line connections.
*Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.
*Installation of these units that require a TXV Kit to be installed on the indoor coil: PLEASE NOTE: THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL
6