EMI T4HB, T3HB, T2HB, S2HB manual With a screw Driver punch

Page 8

T2HB, T3HB, and T4HB Installation Instructions Section

 

ELECTRICAL WIRING

 

5. With a screw-

 

 

driver punch

 

Mounting

out and remove

 

Screw

the knock-outs

 

 

in the low &

 

 

high Volt elec-

Low Volt

High Volt

trical connec-

 

 

tion box.

 

 

 

Knock-out

 

Note: Power should be run to a weather proof disconnect box usually within 3 feet of the unit.

6.From the disconnect box feed the high Volt wires through a weather proof con- duit and run the power through the 7/8" hole (from knock-out) in the unit’s electri- cal box. anchor with a strain relief fitting. Refer to the wiring diagram.

7.Following the wiring diagram, run wires to the High volt pigtail in the control box and attach L1 and L2 connections. Also run green wire to ground lug.

8.Check wiring diagram for the required num- ber of low voltage wires to be run between indoor and outdoor sections.

9.Connect the 24 volt wiring matching color to terminal block designation for each zone as labeled. Refer to the wiring diagram on the inside front panel of the condenser, and also refer to the wiring diagram on the indoor unit. Low volt interconnect should be at least 18 awg.

When connecting to the rear terminal strip there are two approaches.

a)Using a long straight screw driver over the top of the front terminal strip while holding the wire with needle nose pliers from below.

b)Remove the mounting screw (stubby screwdriver), then pull the entire front terminal strip forward, disengaging the tab on left from slot. When finished, reinsert terminal strip tab into slot and reinstall mounting screw.

! Caution !

Make sure that Low Volt wiring for each circuit is connected to the matching Low Volt wiring.

10.Replace the unit’s electric box cover and the front panel and tighten screws.

Multi-zone Heat Pump Condensing Units

8

www.enviromaster.com

Image 8
Contents Installation, operation and maintenance Manual To the Installer Safety Instructions EMI America Series Multi-zone Heat Pump Condensing UnitsInstaller Supplied Items DescriptionSystem Options Items for ConsiderationS2HB Installation Instructions Section S2HB Unit Mounting SectionS2HB Electrical Wiring Installation Section Rating plateLow Volt Connection Completed Electrical ConnectionsDiagram Electrical WiringWith a screw Driver punch Multi-Zone Heat Pump Refrigerant Piping Installation S2HB, T2HB, T3HB, & T4HB modelsTrap Installation Trap may be fabricated usingBraze tubing into fittings Recap of COMPLETing Piping ConnectionsField Charging Multi-zone Heat Pump Field Charging Multi-zone Heat Pump Field Charging Multi-zone Heat Pump Field Charging Multi-zone Heat Pump Field Charging On the R-22 Scale of the low- side gauge Starting the UnitStart-up and Troubleshooting Test procedure Test Unit Performance DataMulti-zone Condenser Sequence of Operation PumpDefrost Control General Recommendations Operation and MaintenanceSpecific Changes S2HB dimensions and specifications Specifications may change without noticeS2HB System Performance HspfUNH S2HB T2HB, T3HB, and T4HB dimensions and specifications Liquid SuctionT2HB, T3HB, and T4HB specifications T2HB, T3HB, & T4HB modelsT2HB, T3HB, or T4HB Top Discharge CAH T3HB, or T4HB EMI’s High Seer Product Line Phone Success Drive Fax Rome, NY

S2HB, T2HB, T3HB, T4HB specifications

The EMI T4HB, T3HB, T2HB, and S2HB models represent innovative advancements in the field of electronic security and surveillance technology. Each model is designed to meet specific security needs while integrating cutting-edge features, making them suitable for a variety of applications, from residential monitoring to large-scale facility management.

Starting with the T4HB, this model is known for its high-definition video capabilities and robust build quality. It offers 4K resolution, providing crystal-clear image quality that captures fine details, making it easier to identify subjects. The T4HB is equipped with advanced night vision technology, allowing it to perform optimally in low light conditions. Additionally, it features motion detection and smart analytics that minimize false alarms and provide users with real-time alerts. The integration with cloud storage solutions ensures that footage is securely saved and easily accessible from various devices.

The T3HB is a slightly scaled-back version, yet it does not compromise on essential features. It supports 1080p full HD resolution and incorporates many of the same intelligent analytics capabilities as its T4HB counterpart. With a wide-angle lens, the T3HB allows coverage of larger areas with fewer cameras. Its weather-resistant design makes it suitable for both indoor and outdoor installations, protecting it from the elements and ensuring reliable performance.

Next is the T2HB, which balances performance and affordability. This model retains high-definition video quality and basic motion detection features, making it ideal for budget-conscious consumers who still want reliable surveillance. The T2HB focuses on user-friendliness with simple setup processes and mobile app integration that allows for easy remote monitoring, making it an attractive option for homeowners.

Lastly, the S2HB is engineered for versatility. It combines the advantages of all previous models, providing excellent video quality and configurable settings for personalized security needs. The S2HB stands out with its smart home compatibility, enabling integration with various smart devices in a home security ecosystem. Its compact design allows for flexible mounting options without compromising performance.

Together, the EMI T4HB, T3HB, T2HB, and S2HB models reflect a commitment to quality, innovation, and user satisfaction in the modern security landscape. They cater to various needs, ensuring that users can find a suitable solution for their surveillance requirements while benefiting from advanced technologies that enhance security and peace of mind.