Bard PA13422-C, PA13242-A, PA13302-A, PA13362-A, PA13482-B, PA13602-B, PA13482-C, PA13362-B Contents

Page 2

Contents

Getting Other Informations and Publications

......... 3

Start Up and Operation

 

General Instructions

 

 

General

16

 

 

Topping Off System Charge

16

Important

4

Safety Practices

16

Shipping Damage

4

Start Up Notes

16

General

4

Three Phase Scroll Compressor Start Up

 

Field Installed Heater Packages (Optional)

4

Information

17

Installation

 

 

Sequence of Operation

17

 

 

Indoor Blower Motor

17

Location

10

Compressor Control Module

17 & 18

Slab Mounting

10

Adjustments

18

Typical Installations

10 & 13

Low Ambient Control

18

Condensate Drain Trap

13

 

 

Air Filters

13

Service and Troubleshooting

 

Wiring – Main Power

14

Service Hints

19

Wiring – 24V Low Voltage Control Circuit

14

Pressure Service Ports

19

Transformer Taps

14

R-410ARefrigerant Charge

19

Thermostats

14

Fan Blade Settings

19

 

 

 

Pressure Tables

20 & 21

 

 

 

Suction and Discharge Tube Brazing

22

 

 

 

Troubleshooting GE Blower Motors

23-24

Figures

 

 

Tables

 

 

 

Figure 1A

Unit Dimensions

8

Table

1

Rated CFM & ESP

4

Figure 1B

Unit Dimensions

9

Table

2

Electrical Specifications

5

Figure 2

Slab Mounting at Ground Level

11

Table

3

Opt. Field Installed Heater Packages

6

Figure 3

Airflow and Service Access

 

Table

4

Opt. Field Installed Elec. Heater

7

 

Clearances

11

Table

5

Filter Requirements & Sizes

13

Figure 4

Elevated Mounting Platform

12

Table

6

Thermostat Wire Size

14

Figure 5

Condensate Drain Trap

13

Table

7

Wall Thermostats

14

Figure 6

Low Voltage Wiring

15

Table

8

Indoor Blower Performance

19

Figure 7

Low Ambient Control Wiring

18

Table

9

Pressure Table

20

Figure 8

Fan Blade Setting

19

Table

10

Pressure Table

21

Figure 9

Brazing Diagram

22

 

 

 

 

Figure 10

Motor Connections

23

 

 

 

 

Figure 11

Wiring (Connections/Voltage)

24

 

 

 

 

Manual

2100-467K

Page

2 of 24

Image 2
Contents Installation Instructions Single Package AIR Conditioners Contents Getting Other Information and Publications For more information, contact these publishersShipping Damage Field Installed Heater Packages OptionalGeneral Instructions GeneralElectrical specifications Hz Circuit a2100-467K Optional Field Installed Electric Heater Table BtuhUnit Dimension Chart Dimensions of UnitsUnit Location InstallationTypical Installations GeneralAirflow and Service access clearances Slab Mounting at Ground levelElevated mounting platform As requiredFilter requirements & Sizes Condensate Drain TrapAIR Filters Condensate Drain TrapTransformer Taps Wiring Main PowerWiring 24V LOW Voltage Control Circuit ThermostatsLow Voltage Wiring LOW Voltage WiringTopping off system charge Safety practicesStart UP Start UP NotesSequence of Operation Three Phase Scroll Compressor STart UP InformationStart UP and Operation INDOOR Blower MotorAdjustable DELAY-ON-MAKE and DELAY-ON-BREAK Timer AdjustmentsAlarm Output LOW ambient controlPressure Service Ports Service and TroubleshootingService Hints FAN Blade SettingsPressure Table On Page 20 in Table126 128 129 Brazing Diagram Suction and Discharge Tube BrazingTroubleshooting GE X13-Series ECM2.3 Motors Troubleshooting GE X13-Series ECM2.3 Motors Cont’d

PA13422-A, PA13482-C, PA13362-A, PA13242-A, PA13602-B specifications

The Bard PA13362-B, PA13482-B, PA13482-A, PA13422-C, and PA13422-B are advanced heating and cooling systems designed to meet the diverse needs of residential and commercial settings. These models are well-regarded for their innovative technologies, efficiency, and reliability.

At the heart of these units is Bard's commitment to superior engineering. The PA13362-B and PA13482-B, for instance, are equipped with powerful compressors that deliver exceptional cooling performance while maintaining energy efficiency. Both models utilize a high-efficiency refrigerant which not only complies with environmental regulations but also enhances their cooling capabilities. Their robust construction ensures durability and longevity, making them a smart investment for users looking for long-term solutions.

The PA13482-A and PA13422-C models are noteworthy for their advanced airflow design, which ensures consistent temperature distribution throughout the space. This is especially beneficial in large areas where temperature fluctuations can be a concern. The designs are optimized to minimize noise levels, providing a tranquil environment without compromising on performance.

Energy efficiency is a hallmark feature across these models. Many units incorporate variable-speed technology, which allows them to adjust their operation based on the specific heating or cooling needs of the environment. This not only reduces energy consumption but also leads to lower utility bills over time. Furthermore, the units are designed with easy maintenance features, enabling users to perform routine checks with minimal effort.

The PA13422-B model stands out with its programmable control options, which allow for customized heating and cooling schedules. This feature is particularly advantageous for businesses and households looking to optimize their energy usage and occupancy comfort. The intuitive interface is user-friendly, ensuring quick access to settings and adjustments.

Overall, Bard's PA series units offer a combination of high performance, efficiency, and user-friendly features. They are suitable for various applications, enhancing comfort in schools, offices, and homes alike. With a focus on innovation and customer satisfaction, Bard continues to set the standard in heating and cooling technology, making their models some of the most reliable choices in the market today.