Bard PA13482-B General Instructions, Shipping Damage, Field Installed Heater Packages Optional

Page 4

GENERAL INSTRUCTIONS

IMPORTANT

The equipment covered in this manual is to be installed by trained, experienced service and installation technicians. All duct work, supply and return

ducts, must be properly sized for the design airflow requirement of the equipment. ACCA is an excellent guide to proper sizing. All duct work or portions thereof not in the conditioned space should be properly insulated in order to both conserve energy and prevent condensation or moisture damage.

SHIPPING DAMAGE

Upon receipt of equipment, the carton should be checked for external signs of shipping damage. If damage is found, the receiving party must contact the last carrier immediately, preferably in writing, requesting inspection by the carrier’s agent.

GENERAL

The refrigerant system is completely assembled and charged. All internal wiring is complete.

The unit is designed for use with or without duct work. Flanges are provided for attaching the supply and return ducts.

These instructions explain the recommended method to install the air cooled self-contained unit and the electrical wiring connections to the unit.

These instructions and any instructions packaged with any separate equipment required to make up the entire system should be carefully read before beginning the installation. Note particularly “Starting Procedure” and any tags and/or labels attached to the equipment.

While these instructions are intended as a general recommended guide, they do not supersede any national and/or local codes in any way. Authorities having jurisdiction should be consulted before the installation is made.

FIELD INSTALLED HEATER PACKAGES (OPTIONAL)

These packaged air conditioners are manufactured without supplementary electric heaters. Supplementary heaters are available for simple, fast field installation.

A separate power circuit is required for the supplementary heaters.

IMPORTANT: Refer to Table 1 when designing duct work for maximum available static pressure with heater installed.

Refer to data shown in Table 3 and 4 for proper application information on all available heater combinations and what units they can be used with. It also shows the applicable circuit ampacities, fuse size, and wire size for each heater combination.

table 1

Rated CFM and External Static Pressure

(ESP)

Model

Rated

Recommended

Rated

Max.

No.

CFM

Airflow Range

ESP

ESP

PA1324

800

Note

0.18

0.50

PA1330

1000

Note

0.23

0.50

PA1336

1100

Note

0.23

0.50

PA1342

1450

Note

0.23

0.50

PA1348

1550

Note

0.28

0.50

PA1360

1750

Note

0.28

0.50

NOTE: ECM motors provide rated CFM up to 0.50 ESP

Manual

2100-467K

Page

4 of 24

Image 4
Contents Installation Instructions Single Package AIR Conditioners Contents Getting Other Information and Publications For more information, contact these publishersField Installed Heater Packages Optional General InstructionsShipping Damage GeneralElectrical specifications Hz Circuit a2100-467K Optional Field Installed Electric Heater Table BtuhUnit Dimension Chart Dimensions of UnitsUnit Installation Typical InstallationsLocation GeneralAirflow and Service access clearances Slab Mounting at Ground levelElevated mounting platform As requiredCondensate Drain Trap AIR FiltersFilter requirements & Sizes Condensate Drain TrapWiring Main Power Wiring 24V LOW Voltage Control CircuitTransformer Taps ThermostatsLow Voltage Wiring LOW Voltage WiringSafety practices Start UPTopping off system charge Start UP NotesThree Phase Scroll Compressor STart UP Information Start UP and OperationSequence of Operation INDOOR Blower MotorAdjustments Alarm OutputAdjustable DELAY-ON-MAKE and DELAY-ON-BREAK Timer LOW ambient controlService and Troubleshooting Service HintsPressure Service Ports FAN Blade SettingsPressure Table On Page 20 in Table126 128 129 Brazing Diagram Suction and Discharge Tube BrazingTroubleshooting GE X13-Series ECM2.3 Motors Troubleshooting GE X13-Series ECM2.3 Motors Cont’d

PA13422-A, PA13482-C, PA13362-A, PA13242-A, PA13602-B specifications

The Bard PA13362-B, PA13482-B, PA13482-A, PA13422-C, and PA13422-B are advanced heating and cooling systems designed to meet the diverse needs of residential and commercial settings. These models are well-regarded for their innovative technologies, efficiency, and reliability.

At the heart of these units is Bard's commitment to superior engineering. The PA13362-B and PA13482-B, for instance, are equipped with powerful compressors that deliver exceptional cooling performance while maintaining energy efficiency. Both models utilize a high-efficiency refrigerant which not only complies with environmental regulations but also enhances their cooling capabilities. Their robust construction ensures durability and longevity, making them a smart investment for users looking for long-term solutions.

The PA13482-A and PA13422-C models are noteworthy for their advanced airflow design, which ensures consistent temperature distribution throughout the space. This is especially beneficial in large areas where temperature fluctuations can be a concern. The designs are optimized to minimize noise levels, providing a tranquil environment without compromising on performance.

Energy efficiency is a hallmark feature across these models. Many units incorporate variable-speed technology, which allows them to adjust their operation based on the specific heating or cooling needs of the environment. This not only reduces energy consumption but also leads to lower utility bills over time. Furthermore, the units are designed with easy maintenance features, enabling users to perform routine checks with minimal effort.

The PA13422-B model stands out with its programmable control options, which allow for customized heating and cooling schedules. This feature is particularly advantageous for businesses and households looking to optimize their energy usage and occupancy comfort. The intuitive interface is user-friendly, ensuring quick access to settings and adjustments.

Overall, Bard's PA series units offer a combination of high performance, efficiency, and user-friendly features. They are suitable for various applications, enhancing comfort in schools, offices, and homes alike. With a focus on innovation and customer satisfaction, Bard continues to set the standard in heating and cooling technology, making their models some of the most reliable choices in the market today.