Bard WA3S, WL3S, WL5S, WA5S manual Ventilation System Packages, Blank OFF Plate BOP Standard

Page 3

Ventilation System Packages

Bard Wall-Mounts are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality requirements. All units are equipped with a blank off plate as the standard ventilation package. All ventilation packages can be built-in at the factory, or field- installed at a later date.

BLANK OFF PLATE - BOP

STANDARD

A blank off plate is installed on the inside of the service door. It covers the air inlet openings which restricts any outside air from entering the unit. The blank off plate should be utilized in applications where outside air is not required to be mixed with the conditioned air.

Motorized Fresh Air Damper

MOTORIZED FRESH AIR DAMPER - MFAD

OPTIONAL

The motorized fresh air damper is internally mounted behind the service door and allows outside ventilation air, up to 25% of the total airflow rating of the unit, to be introduced through the air inlet openings and to be mixed with the conditioned air. The two position damper can be fully open or closed. The damper blade is powered open by a 24VAC motor with spring return on power loss. The damper can be controlled by indoor blower operation or can be field connected to be managed based on building occupancy.

NOTE: This vent system is intake only without built-in exhaust capability. Building will likely require separate field installed barometric relief or mechanical exhaust elsewhere within the conditioned space. Other building systems will govern actual amount of intake air.

COMMERCIAL ROOM VENTILATOR

Economizer

ENERGY RECOVERY VENTILATOR

COMMERCIAL ROOM VENTILATOR - CRVMP

OPTIONAL

The built-in commercial room ventilator is internally mounted behind the service door and allows outside ventilation air, up to 50% of the total airflow rating of the unit, to be introduced through the air inlet openings. It includes a built-in exhaust air damper with integral bug screen. Automatic control is integrated to maintain desired ventilation air at the various supply airflows.

The commercial room ventilator (CRV) is a simple and innovative approach to improving the indoor air quality by providing fresh air intake and exhaust capability through the CRV. The damper can be easily adjusted to control the amount of fresh air supplied into the building. The CRV can be controlled by indoor blower operation or field controlled based on room occupancy. The CRV is power open - spring return on power loss. Complies with ANSI/ASHRAE Standard 62.1 “Ventilation for Acceptable Indoor Air Quality.”

ECONOMIZER - ECONWM-Series

OPTIONAL

The built-in economizer system is internally mounted behind the service door and allows outdoor air to be introduced through the air inlet openings. The amount of outdoor air varies in response to the system controls and settings defined by the end user. It includes a built-in exhaust air damper. The economizer is designed to provide “free cooling” when outside air conditions are cool and dry enough to satisfy cooling requirements without running the compressor. This in turn provides lower operating costs, while extending the life of the compressor.

ECONWMT Equipment Building versions have extended air intake hood to deliver up to 100% of cooling rated airflow.

￿16" for ECONWMT-E2 or T2, and E3 or T3

￿18" for ECONWMT-E5 or T5

ECONWMS Classroom versions have 3" air intake hood to deliver up to 75% of cooling rated airflow.

Standard Features:

Fully modulating

Honeywell Direct Drive Hi-Torque Actuator

No linkage required

Simple single blade design

Positive shut-off with non-stick gaskets

Electronic DB and/or Enthalpy sensors depending upon version

Honeywell JADE electronic economizer module with precision settings and diagnostics

DB or Enthalpy economizer versions available

WALL-MOUNT ENERGY RECOVERY VENTILATOR - ERVF

OPTIONAL

The wall-mount energy recovery ventilator (ERV) is a highly innovative approach to meeting indoor air quality ventilation requirements as established by ANSI/ASHRAE Standard 62.1. The ERV allows from 200 to 450 CFM (depending upon model) of fresh air and exhaust through the unit while maintaining superior indoor comfort and humidity levels. In most cases this can be accomplished without increasing equipment sizing or operating costs. Heat transfer efficiency is up to 67% during summer and 75% during winter conditions.

The ERV consists of a unique “rotary energy recovery cassette” that provides effective sensible and latent heat transfer capabilities during summer and winter conditions. Various control schemes are addressed including limiting ventilation during building occupancy only.

The ERV is designed to be internally mounted behind the service door in the WA/LS model wall-mount units. It can be built-in at the factory or field installed as an option. ERVF-*5 can be independently adjusted for intake and exhaust rates.

Manufactured under U.S. Patent Nos. 5,485,878; 5,301,744.

Form No.

S3378-1112

Supersedes

S3378-712

Page

3 of 12

Image 3
Contents WALL-MOUNT Step Capacity AIR Conditioners Engineered FeaturesSpecifications 3 Ton through 5 Ton Capacity and Efficiency RatingsIndoor Blower Performance CFM 0.00 through 0.80 H2O Blank OFF Plate BOP Standard Ventilation System PackagesWA3S/WL3S Ventilation Airflow WA4S/WL4S Ventilation AirflowWA5S/WL5S Ventilation Airflow HRT HRS HRL Performance and Application Data- WERV-*5Single Circuit Multiple Circuit Electrical SpecificationsNominal At 240V At 208V At 480V At 460V Ph Amps Btuh Heater Packages Field Installed WA3, WA4 & WA5SHeater Packages Field Installed WL3, WL4 & WL5S Electric Heat TableSupply Air Acoustical Plenum Return Air Acoustical Plenum Free Blow Acoustical PlenumWA/L3S Sound Data Matrix dBA @ 10 feet 1st Stage Cooling Application Data Outdoor Temperature 2nd Stage Cooling Application Data Outdoor TemperatureWA3-4-5S Models Ventilation Options Air Conditioning Wall-Mount Model NomenclatureWA 3S P X

WA3S, WA5S, WL5S, WL3S specifications

Bard WA5S, WL3S, WL5S, and WA3S are advanced heating, ventilation, and air conditioning (HVAC) systems designed to deliver efficient and reliable climate control solutions for various indoor environments. These models are particularly well-suited for residential and commercial applications, prioritizing energy efficiency, comfort, and user-friendly features.

One of the notable features of Bard's HVAC systems is their impeccable design, which allows for easy installation in diverse settings, including utility rooms and sidewalls. The WA series, known for its robust wall-mounted units, offers flexibility in placement while maintaining optimal airflow and temperature control. The WL series enhances this further with a high-efficiency heat pump option, providing both heating and cooling capabilities in a single unit, thereby streamlining operations and reducing energy costs.

Energy efficiency is a hallmark of Bard's technology. These models typically come equipped with high Seasonal Energy Efficiency Ratios (SEER) and Heating Seasonal Performance Factors (HSPF). This means they consume less electric energy while providing superior heating and cooling performance, contributing to lower utility bills and a reduced carbon footprint. The innovative design also reduces noise levels during operation, creating a more pleasant indoor environment.

Another significant aspect of the Bard WA and WL series is their durable construction. Built to withstand various climatic conditions, these HVAC systems use high-quality materials that ensure longevity and reliability. The units feature corrosion-resistant finishes and sturdy components capable of withstanding harsh indoor and outdoor environments.

Incorporated smart technologies provide added convenience. Many of these models support programmable thermostats and zoning systems, allowing users to customize their comfort levels according to individual preferences. This not only promotes comfort but also enhances energy savings, as heating and cooling can be adjusted based on occupancy and usage patterns.

Furthermore, Bard's commitment to easy maintenance is evident in the design of these units. Access panels are strategically placed to simplify service requirements, while filter maintenance is straightforward, ensuring optimal performance and longevity.

Overall, Bard WA5S, WL3S, WL5S, and WA3S systems stand out in the HVAC market for their combination of energy efficiency, flexibility, durability, and user-friendly features, making them a compelling choice for those looking to enhance their indoor climate control solutions.