Bard 2100-404E Wall Mount General Information, AIR Conditioner Wall Mount Model Nomenclature

Page 4

WALL MOUNT GENERAL INFORMATION

AIR CONDITIONER WALL MOUNT MODEL NOMENCLATURE

WA 37 2

A

10

X

X

X

X X A

 

 

 

 

 

 

 

 

 

MODEL

 

KW

NUMBER

REVISIONS

 

CAPACITY

 

VOLTS & PHASE

 

 

25

-

2 Ton

 

A - 230/208/60/1

 

 

37

-

3 Ton

 

B - 230/208/60/3

 

 

 

 

 

 

C - 460/60/3

VENTILATION OPTIONS

X - Barometric Fresh Air Damper (Standard)

B - Blank-off Plate

COLOR OPTIONS

X - Beige (Standard)

1 - White

2- Mesa Brown

4 - Buckeye Gray

5 - Desert Brown

6 - Dark Bronze

CONTROL MODULES (See Spec.

Sheet S3208)

COIL OPTIONS

X - Standard

1 - Phenolic Coated Evaporator

2 - Phenolic Coated Condenser

3 - Phenolic Coated Evaporator

and Condenser

M - Motorized Fresh Air Damper

V - Commercial Room Ventilator - Motorized with Exhaust E - Economizer (Internal - Fully Modulating with Exhaust R - Energy Recovery Ventilator - with Exhaust

FILTER OPTIONS

OUTLET OPTIONS

X - 1-Inch Throwaway

X - Front (Standard)

(Standard)

T - Top on WA30 & WA37 Models

W- 1-Inch Washable

 

P - 2-Inch Pleated

 

NOTE: For 0KW and circuit breakers (230/208 Volt) or pull disconnects (460 Volt) applications, insert 0Z in the KW field of model no.

TABLE 1 – ELECTRICAL SPECIFICATIONS

 

 

 

3

1

2

2

3

1

2

2

 

 

 

 

 

 

 

 

 

Maximum

 

 

 

 

 

 

 

 

 

 

 

Minimum

External

Field Power

 

 

 

 

 

 

 

 

 

Fuse

 

 

 

 

No.

 

Maximum

 

 

Circuit

or Ckt.

Wire Size

Ground

 

 

 

External

Field

 

Ampacity

Breaker

 

 

Wire Size

 

Rated

Field

Minimum

Fuse or

Power

Ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Volts/

Power

Circuit

Ckt.

Wire

Wire

CKT

CKT

CKT

CKT

CKT

CKT

CKT

CKT

Models

Phases

Circuits

Ampacity

Breaker

Size

Size

A

B

A

B

A

B

A

B

WA302-A0Z

 

1

24

35

8

10

NA

NA

NA

NA

NA

NA

NA

NA

A05

230/208-1

1

31

35

8

10

NA

NA

NA

NA

NA

NA

NA

NA

A10

 

1

57

60

6

10

NA

NA

NA

NA

NA

NA

NA

NA

A15

 

1 or 2

83

90

4

8

55

26

60

30

4

10

8

10

WA302-B0Z

 

1

17

20

12

12

NA

NA

NA

NA

NA

NA

NA

NA

B09

230/208-3

1

32

35

8

10

NA

NA

NA

NA

NA

NA

NA

NA

B15

 

1

50

50

8

10

NA

NA

NA

NA

NA

NA

NA

NA

WA302-C0Z

 

1

10

15

14

14

NA

NA

NA

NA

NA

NA

NA

NA

C09

460-3

1

17

20

12

12

NA

NA

NA

NA

NA

NA

NA

NA

C15

 

1

26

30

10

10

NA

NA

NA

NA

NA

NA

NA

NA

WA372-A0Z

 

1

28

35

8

10

NA

NA

NA

NA

NA

NA

NA

NA

A05

 

1

32

35

8

10

NA

NA

NA

NA

NA

NA

NA

NA

A08

230/208-1

1

47

50

8

10

NA

NA

NA

NA

NA

NA

NA

NA

A10

 

1

58

60

6

10

NA

NA

NA

NA

NA

NA

NA

NA

A15

 

1 or 2

84

90

4

8

58

26

60

30

6

10

10

10

WA372-B0Z

 

1

20

25

10

10

NA

NA

NA

NA

NA

NA

NA

NA

B06

230/208-3

1

24

25

10

10

NA

NA

NA

NA

NA

NA

NA

NA

B09

1

33

35

8

10

NA

NA

NA

NA

NA

NA

NA

NA

B15

 

1

51

60

6

10

NA

NA

NA

NA

NA

NA

NA

NA

WA372-C0Z

 

1

11

15

14

14

NA

NA

NA

NA

NA

NA

NA

NA

C06

 

1

12

15

14

14

NA

NA

NA

NA

NA

NA

NA

NA

C09

460-3

1

17

20

12

12

NA

NA

NA

NA

NA

NA

NA

NA

C12

 

1

21

25

10

10

NA

NA

NA

NA

NA

NA

NA

NA

C15

 

1

26

30

10

10

NA

NA

NA

NA

NA

NA

NA

NA

1Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors.

2 Based on 75° copper wire. All wiring must conform to the National Electrical Code and all local codes.

3 These "Minimum Circuit Ampacity" values are to be used for sizing the field power conductors. Refer to the National Electric Code (latest revision), Article 310 for power conductor sizing.

CAUTION: When more than one field power conductor circuit is run through one conduit, the conductors must be derated. Pay special attention to note 8 of table 310 regarding Ampacity Adjustment Factors when more than three conductors are in a raceway.

Manual

2100-404E

Page

4 of 19

Image 4
Contents Wall Mounted Contents Getting Other Information and Publications For More INFORMATION, Contact These PublishersWall Mount General Information Electrical SpecificationsAIR Conditioner Wall Mount Model Nomenclature Dimensions of Basic Unit Nominal General Shipping DamageElectric Heat Table Fresh AIR Damper Assembly Duct WorkFilters Fresh AIR IntakeInstallation Instructions Wiring Main PowerWall Mounting Information Mounting the UnitWiring LOW Voltage Wiring Wall Thermostat Thermostat Wire SizeLOW Voltage Connections Operating Voltage RangeMounting Instructions WALL-MOUNTING Instructions Common WALL-MOUNTING Installations Electric Heat Clearance LOW Voltage Wiring Start UP Pressure Service Ports Compressor Control ModuleTroubleshooting FAN Blade Setting DimensionsRemoval of FAN Shroud Refrigerant ChargeOutdoor Temperature F Cooling PressureOptional Accessories WA302-A WA372-A WA302-B WA372-B WA302-C WA372-C

2100-404E specifications

The Bard 2100-404E is an advanced heating and cooling unit designed to provide efficient climate control solutions for various applications. This innovative model is renowned for its compact design and high performance, making it suitable for both residential and commercial settings.

One of the standout features of the Bard 2100-404E is its energy efficiency. It comes equipped with a high-efficiency compressor that not only helps in reducing energy consumption but also lowers operational costs. This model adheres to the latest energy efficiency standards, ensuring that users benefit from significant savings on their utility bills.

The unit utilizes environmentally friendly refrigerants, which contribute to its eco-friendly profile. By minimizing its carbon footprint, the Bard 2100-404E aligns with contemporary environmental standards and regulations, making it a responsible choice for conscientious consumers.

Another notable characteristic of the Bard 2100-404E is its robust construction and durability. The unit is built with high-quality materials designed to withstand harsh weather conditions, ensuring longevity and reliable performance over time. This makes it ideal for installation in various environments, including those subjected to extreme temperatures.

The Bard 2100-404E features a user-friendly digital control panel that allows for easy adjustments and monitoring of settings. Users can effortlessly customize their heating and cooling preferences, optimizing comfort within their spaces. The system also includes programmable settings, enhancing convenience and energy savings.

In terms of technologies, the Bard 2100-404E incorporates modern HVAC advancements such as variable speed fans and multi-zone capabilities. These features result in enhanced temperature control and improved indoor air quality, ensuring that every corner of a space is evenly conditioned.

Other characteristics include relatively low noise levels, making the unit suitable for installation in noise-sensitive areas. Additionally, the Bard 2100-404E is designed for easy maintenance, with accessible components that simplify servicing and repairs.

In conclusion, the Bard 2100-404E represents a smart investment for those seeking an efficient, durable, and versatile heating and cooling solution. With its energy-saving features, environmental consciousness, and cutting-edge technologies, it stands out as a premier choice for modern climate control needs.