COMPRESSOR CONTROL MODULE

The compressor control module is optional on the models covered by this manual. The compressor control is an anti-short cycle/lockout timer with high and low pressure switch monitoring and alarm relay output.

Adjustable Delay On Make And Break Timer

On initial power up or any time power is interrupted to the unit, the delay on make period begins, which will be 2 minutes plus 10% of the delay on break setting. When the delay on make is complete and the high pressure switch (and low pressure switch if employed) is closed, the compressor contactor is energized. Upon shutdown, the delay or break timer starts and prevents restart until the delay on break and delay on make periods have expired.

During routine operation of the unit with no power interruptions the compressor will operate on demand with no delay.

High Pressure Switch and Lockout Sequence

If the high pressure switch opens, the compressor contactor will de-energize immediately. The lockout timer will go into a soft lockout and stay in soft lockout until the high pressure switch closes and the delay on break time has expired. If the high pressure switch opens again in this same operating cycle, the unit will go into manual lockout condition and the alarm relay circuit will energize. Recycling the wall thermostat resets the manual lockout.

Low Pressure Switch, Bypass, and Lockout Sequence

If the low pressure switch opens for more than 120 seconds, the compressor contactor will de-energize and go into a soft lockout. Regardless the state of the low pressure switch, the contactor will reenergize after the delay on make time delay has expired. If the low pressure switch remains open, or opens again for longer than 120 seconds the unit will go into manual lockout condition and the alarm relay circuit will energize. Recycling the wall thermostat resets the manual lockout.

Alarm Relay Output

Alarm terminal is output connection for applications where alarm relay is employed. This terminal is powered whenever compressor is locked out due to HPC or LPC sequences as described.

NOTE: Both high and low pressure switch controls are inherently automatic reset devices. The high pressure switch and low pressure switch cut out and cut in settings are fixed by specific air conditioner or heat pump unit model. The lockout features, both soft and manual, are a function of the Compressor Control Module.

ADJUSTMENTS

Adjustable Delay on Make and Delay on Break Timer

The potentiometer is used to select Delay on Break time from 30 seconds to 5 minutes. Delay on Make (DOM) timing on power-up and after power interruptions is equal to 2 minutes plus 10% of Delay on Break (DOB) setting:

0.5 minute

(30 seconds) DOB

= 123 second DOM

1.0 minute

(60 seconds) DOB

= 126 second DOM

2.0minute (120 seconds) DOB = 132 second DOM

3.0minute (180 seconds) DOB = 138 second DOM

4.0minute (240 seconds) DOB = 144 second DOM

5.0minute (300 seconds) DOB = 150 second DOM

During routine operation of the unit with no power interruptions, the compressor will operate on demand with no delay.

Typical Settings for Dual Unit Installation:

Unit 1: DOB set at 2 minutes, and DOM is 132 seconds

Unit 2: DOB set at 4 minutes, and DOM is 144 seconds

PRESSURE SERVICE PORTS

High and low pressure service ports are installed on all units so that the system operating pressures can be observed. Pressure tables can be found later in the manual covering all models. It is imperative to match the correct pressure table to the unit by model number.

Manual

2100-404E

Page

16 of 19

Image 16
Contents Wall Mounted Contents Getting Other Information and Publications For More INFORMATION, Contact These PublishersWall Mount General Information Electrical SpecificationsAIR Conditioner Wall Mount Model Nomenclature Dimensions of Basic Unit Nominal General Shipping DamageElectric Heat Table Fresh AIR Damper Assembly Duct WorkFilters Fresh AIR IntakeInstallation Instructions Wiring Main PowerWall Mounting Information Mounting the UnitWiring LOW Voltage Wiring Wall Thermostat Thermostat Wire SizeLOW Voltage Connections Operating Voltage RangeMounting Instructions WALL-MOUNTING Instructions Common WALL-MOUNTING Installations Electric Heat Clearance LOW Voltage Wiring Start UP Pressure Service Ports Compressor Control ModuleTroubleshooting FAN Blade Setting DimensionsRemoval of FAN Shroud Refrigerant ChargeOutdoor Temperature F Cooling PressureOptional Accessories WA302-A WA372-A WA302-B WA372-B WA302-C WA372-C

2100-404E specifications

The Bard 2100-404E is an advanced heating and cooling unit designed to provide efficient climate control solutions for various applications. This innovative model is renowned for its compact design and high performance, making it suitable for both residential and commercial settings.

One of the standout features of the Bard 2100-404E is its energy efficiency. It comes equipped with a high-efficiency compressor that not only helps in reducing energy consumption but also lowers operational costs. This model adheres to the latest energy efficiency standards, ensuring that users benefit from significant savings on their utility bills.

The unit utilizes environmentally friendly refrigerants, which contribute to its eco-friendly profile. By minimizing its carbon footprint, the Bard 2100-404E aligns with contemporary environmental standards and regulations, making it a responsible choice for conscientious consumers.

Another notable characteristic of the Bard 2100-404E is its robust construction and durability. The unit is built with high-quality materials designed to withstand harsh weather conditions, ensuring longevity and reliable performance over time. This makes it ideal for installation in various environments, including those subjected to extreme temperatures.

The Bard 2100-404E features a user-friendly digital control panel that allows for easy adjustments and monitoring of settings. Users can effortlessly customize their heating and cooling preferences, optimizing comfort within their spaces. The system also includes programmable settings, enhancing convenience and energy savings.

In terms of technologies, the Bard 2100-404E incorporates modern HVAC advancements such as variable speed fans and multi-zone capabilities. These features result in enhanced temperature control and improved indoor air quality, ensuring that every corner of a space is evenly conditioned.

Other characteristics include relatively low noise levels, making the unit suitable for installation in noise-sensitive areas. Additionally, the Bard 2100-404E is designed for easy maintenance, with accessible components that simplify servicing and repairs.

In conclusion, the Bard 2100-404E represents a smart investment for those seeking an efficient, durable, and versatile heating and cooling solution. With its energy-saving features, environmental consciousness, and cutting-edge technologies, it stands out as a premier choice for modern climate control needs.