in iView²) to the administrator. There are also two LED indicators on the SNMP Management Module for fan failure.
The red Alarm Reset Button also functions as a Fan Test button. To verify fan functionality, hold the button down for several seconds, the fans should engage. The fans will turn off when the button is released.
SNMP Management Modules include two twisted pair ports, one for management and one reserved for future use. The Management Module also features a
Installing Management and Application Modules
Installing Applications Modules
To install a module:
1.Remove the blank bracket (if present) covering the slot where the module will be installed. Black Box recommends installing blank brackets in unused module slots.
2.Slide the module into the chassis using the card guides.
3.Secure the module to the chassis by tightening the captive screw. (Refer to the documentation shipped with the module for configuration information.)
4.When installing modules observe ESD precautions, refer to the Electrostatic Discharge Precautions section.
In order to manage a
• Install the
NOTE
This slot is ONLY for the Management Module; do not install Application Modules such as media conversion and mode conversion modules into this slot.
15