Black Box LMC5203A, LMC5208A-R2, LMC5206A Installing Management and Application Modules, Left slot

Page 26

Fans

The 3-Slot Desktop Chassis includes temperature-triggered fans. When the temperature of the chassis reaches 40° C, the two fans activate to cool the chassis. The fans’ operation can be tested by holding the Alarm Reset Button down for 4 to 5 seconds. The fans will activate and then they will turn off when the button is released. If the fans do not activate, contact Black Box. Fans are not end-user replaceable.

The red Alarm Reset Button also functions as a Fan Test button. To verify fan functionality, hold the button down for several seconds, the fans should engage. The fans will turn off when the button is released.

Installing Management and Application Modules

SNMP Management Modules include two twisted pair ports, one for management and one reserved for future use. The Management Module also features a DB-9 serial port, and supports SNMP V1/V2c.

Installing Applications Modules

To install a module:

1.Remove the blank bracket (if present) covering the slot where the module will be installed. Black Box recommends installing blank brackets in unused module slots.

2.Slide the module into the chassis using the card guides.

3.Secure the module to the chassis by tightening the captive screw. (Refer to the documentation shipped with the module for configuration information.)

In order to manage a Desktop Chassis, the SNMP Management Module needs to be installed in the appropriate slot of the chassis.

Install the 3-Slot Desktop Chassis slot SNMP Management Module into the

bottom

left slot.

 

NOTE

This slot is ONLY for the Management Module; do not install Application Modules such as

media conversion and mode conversion modules in this slot.

20

Image 26
Contents Customer Class B FCC and Industry Canada RF Interference StatementsClass a Normas Oficiales Mexicanas NOM Electrical Safety Statement IiiPage Table of Contents Installing Management and Application Modules Slot Rackmount/Desktop Chassis Part Numbers Slot Rackmount ChassisBack Up, Spares, Sold Separately Slot Desktop Chassis About the 20-Slot Rackmount Chassis Slot Rackmount Chassis FeaturesAlarm Reset, Last Gasp and Temperature Gauge Temperature Gauge Reset Alarm ButtonLast Gasp Alarm Snmp Write LockInstalling the 20-Slot Rackmount Chassis LNK/ACT FDX/COL Temp FAN a / FAN BWiring Instruction Guidelines for DC Module in 2DC and Acdc DC Power Supply Module Wiring InstructionsInstalling Snmp Management and Application Modules To install a moduleDual AC, Part Number LMC5207A-R2 Dual DC, Part Number LMC5208A-R2 Slot Rackmount Chassis Specifications ACDC, Part Number LMC5228AAlarm Reset Button Slot Rackmount/Desktop Chassis FeaturesAlarm Reset, Last Gasp, and Temperature Gauge About the 6-Slot Rackmount/Desktop ChassisSuch as LinkLoss, FiberAlert, Force mode Via Snmp on any previous Management ModulesInstalling the 6-Slot Rackmount/Desktop Chassis To install a 6-Slot Rackmount/Desktop ChassisFans DC Power Wiring, Replacing Power Supply and FansUser-Replaceable Power Supplies To install a module Slot Rackmount/Desktop Chassis Specifications Slot Desktop Chassis Features About the 3-Slot Desktop ChassisInstalling the 3-Slot Desktop Chassis Negative ground system configuration default position Power Supply ModulesInstalling Management and Application Modules Left slotBlinks green when data activity occurs On any previous Management ModulesShipping Weight 5 lbs 2.3 kg Slot Desktop Chassis SpecificationsInput Specifications Hardware Feature MatrixBlack Box Customer Service Order toll-free in the U.S. Call 877-877-BBOXFiber Optic Cleaning Guidelines Electrostatic Discharge PrecautionsCertifications Black Box Tech Support FREE! Live /7