30RY/RYH, 30RA/RH manual Operation and maintenance instructions, Aquasnap
Models:
30RY/RYH
30RA/RH
1
1
36
36
Download
36 pages
61.05 Kb
1
2
3
4
5
6
7
8
<
>
Troubleshooting
Maintenance
Configuration
Reset
Setting Up Pro-Dialogcontrol
Master/slave assembly
Typical timer program
Description of the Alarms menu
Description of the Temperatures menu
Safety
Page 1
Image 1
30RA/RH “B” 30RY/RYH “B”
PRO-DIALOG
Control
AQUASNAP
Operation and maintenance instructions
Page 2
Page 1
Image 1
Page 2
Contents
30RA/RH “B” 30RY/RYH “B” PRO-DIALOGControl
Operation and maintenance instructions
AQUASNAP
1 - SAFETY CONSIDERATIONS
TABLE OF CONTENTS
4 - SETTING UP PRO-DIALOGCONTROL
2 - GENERAL DESCRIPTION
5 - PRO-DIALOGCONTROL OPERATION
6 - DIAGNOSTICS - TROUBLESHOOTING
1.2 - Avoid electrocution
1 - SAFETY CONSIDERATIONS 1.1 - General
Fanstart-up
2 - GENERAL DESCRIPTION 2.1 - General
3.2 - Electrical supply to boards
3 - HARDWARE DESCRIPTION 3.1 - General Figure
3.3 - Light emitting diodes on boards
3.4 - The sensors
Evaporator pumps
3.5 - The controls
Evaporator heater
Boiler
DUAL-CIRCUITUNITS
Connector/channel
Description
Terminal
If the automatic heating/cooling changeover function is not selected see sections 4.3.11.3, 5.1 and 5.2 the operation of contacts 1 and 2 is as follows
4.1 - Local interface general features
4 - SETTING UP PRO-DIALOGCONTROL
Main interface
4.2.1 - Description
4.2 - Unit start/stop control
4.2.2 - Stopping the unit in local mode
4.3.1 - Selecting a menu
4.3 - Menus
4.3.2 - Selecting a menu item
4.3.4 - Expand display
STRUCTURE
MENU
TEMPERATURES
CONFIGURATION
Menu tree structure
4.3.5 - Description of the Information menu
FORMAT
INFORMATION MENU 3 continued
UNITS
DESCRIPTION
4.3.7 - Description of the Pressures menu
4.3.6 - Description of the Temperatures menu
4.3.8 - Description of the Setpoints menu
4.3.9 - Description of the Inputs menu
4.3.10.1 - General
4.3.10 - Description of the Outputs/Tests menu
4.3.10.2 - Menu description
4.3.10.4 - Automatic tests
4.3.10.3 - Manual tests
Page
4.3.11.2 - Password
4.3.11- Description of the configuration menu
4.3.11.1- General
SUB-MENUHOLIDAY CONFIGURATION
SUB-MENUPERIOD CONFIGURATION
PERIOD 1 to
PEriod X MEnu
USER 1 CONFIGURATION SUB-MENU2
menu
4.3.11.7 - Description of the Holidays sub-menus
Typical timer program
4.3.11.8 - Description of the Broadcast sub-menu
4.3.13 - Description of the Alarms History menu
4.3.12 - Description of the Alarms menu
4.3.14 - Runtime menu description
4.3.14.1 - Description of the Runtimes 1 menu
4.3.14.2 - Description of Runtimes 2 menu
4.3.14.3 - Maintenance menu description
5 - PRO-DIALOGCONTROL OPERATION
5.1 - Start/stop control
5.2.1 - General
5.2 - Heating/cooling/standby operation
5.2.2 - Heating/cooling/auto selection
5.4 - Control interlock contact
5.3 - Evaporator water pump control
5.5 - Evaporator antifreeze protection
5.6 - Control point
Heating/cooling operating mode
Reset example in cooling mode
5.6.2 - Reset
5.7 - Demand limit
5.8 - Night mode
5.11 - Defrost function
5.14 - Master/slave assembly
5.12 - Additional electric heater stage control
5.13 - Control of a boiler
6.2 - Displaying alarms
6 - DIAGNOSTICS - TROUBLESHOOTING 6.1 - General
6.3 - Resetting alarms
6.4 - Alarm codes
ALARM CODE DESCRIPTIONS continued