Carrier 30RA/RH, 30RY/RYH manual Heating/cooling operating mode

Models: 30RY/RYH 30RA/RH

1 36
Download 36 pages 61.05 Kb
Page 32
Image 32
-Heating/cooling operating mode

The following table summarises the possible selections depending on the control types (local, remote or CCN) and the following parameters:

- Setpoint select in local control: item #12 of the Infor- mation menu permits selection of the active setpoint, if the unit is in local operating type.

-Heating/cooling operating mode

-Control contacts: status of control contacts 5 and 6 (dual- circuit units only). These contacts are only active if the unit is in remote control operating type. See section 3.6.6.

-Control contact 3: status of control contact 3 (single- circuit units only). See section 3.6.4.

-Contol contact 3 selection: this selection, only used for single-circuit units, indicates if contact 3 is used for dual setpoint control or for demand limit control (see User Configuration menu).

-Schedule 2 status: schedule for setpoint selection. See section 4.3.11.6.

REMOTE OPERATING MODE - DUAL-CIRCUIT UNITS

PARAMETER STATUS

 

 

 

 

 

 

 

 

 

HEATING/COOLING

CONTROL

SCHEDULE 2

ACTIVE SETPOINT

OPERATING MODE

CONTACTS

STATUS

 

 

 

 

 

 

 

 

Cooling

sp 1

-

 

 

Cooling setpoint 1

 

 

 

 

 

 

Cooling

sp 2

-

 

 

Cooling setpoint 2

 

 

 

 

 

 

Cooling

sp 3

-

 

 

Cooling setpoint 2

 

 

 

 

 

Cooling

Auto

Occupied

 

Cooling setpoint 1

 

 

 

 

Cooling

Auto

Unoccupied

Cooling setpoint 2

 

 

 

 

 

 

Heating

sp 1

-

 

 

Heating setpoint 1

 

 

 

 

 

 

Heating

sp 2

-

 

 

Heating setpoint 2

 

 

 

 

 

 

Heating

sp 3

-

 

 

Heating setpoint 3

Heating

Auto

Occupied

 

Heating setpoint 1

Heating

Auto

Unoccupied

Heating setpoint 2

Heating

Auto

Holiday

 

Heating setpoint 3

 

 

 

 

 

 

 

CCN OPERATING MODE

 

 

 

 

PARAMETER STATUS

 

 

 

 

 

 

 

 

 

HEATING/COOLING

SCHEDULE 2

ACTIVE SETPOINT

OPERATING MODE

STATUS

 

 

 

 

 

 

 

 

 

 

 

LOCAL OPERATING MODE

PARAMETER STATUS

HEATING/COOLING

LOCAL

SCHEDULE 2

ACTIVE SETPOINT

OPERATING MODE

SETPOINT

STATUS

 

 

SELECTION

 

 

Cooling

sp 1

-

Cooling setpoint 1

Cooling

sp 2

-

Cooling setpoint 2

Cooling

Auto

Occupied

Cooling setpoint 1

Cooling

Auto

Unoccupied

Cooling setpoint 2

 

 

 

 

Heating

sp 1

-

Heating setpoint 1

 

 

 

 

Heating

sp 2

-

Heating setpoint 2

 

 

 

 

Heating

sp 3

-

Heating setpoint 3

 

 

 

 

Heating

Auto

Occupied

Heating setpoint 1

 

 

 

 

Heating

Auto

Unoccupied

Heating setpoint 2

 

 

 

 

Heating

Auto

Holiday

Heating setpoint 3

 

 

 

 

Cooling

Occupied

Cooling setpoint 1

Cooling

Unoccupied

Cooling setpoint 2

 

 

 

Heating

Occupied

Heating setpoint 1

 

 

 

Heating

Unoccupied

Heating setpoint 2

 

 

 

Heating

Holiday

Heating setpoint 3

 

 

 

REMOTE OPERATING MODE - SINGLE-CIRCUIT UNITS

PARAMETER STATUS

 

 

 

 

 

 

 

 

ACTIVE SETPOINT

HEATING/COOLING

CONTROL CONTACT 3

CONTROL CONTACT 3

SCHEDULE 2 STATUS

 

OPERATING MODE

SELECTION

 

 

 

 

 

 

 

 

Cooling

Setpoint

Setpoint 1

-

Cooling setpoint 1

 

 

 

 

 

Cooling

Setpoint

Setpoint 2

-

Cooling setpoint 2

 

 

 

 

 

Cooling

Demand limit

-

Occupied

Cooling setpoint 1

 

 

 

 

 

Cooling

Demand limit

-

Unoccupied

Cooling setpoint 2

 

 

 

 

 

Heating

Setpoint

Setpoint 1

-

Heating setpoint 1

 

 

 

 

 

Heating

Setpoint

Setpoint 2

-

Heating setpoint 2

 

 

 

 

 

Heating

Demand limit

-

Occupied

Heating setpoint 1

 

 

 

 

 

Heating

Demand limit

-

Unoccupied

Heating setpoint 2

 

 

 

 

 

Heating

Demand limit

-

Holiday

Heating setpoint 3

32

Page 32
Image 32
Carrier 30RA/RH, 30RY/RYH manual Heating/cooling operating mode