5.2 - Heating/cooling/standby operation

ACTIVE OPERATING TYPE

 

 

 

STATUS OF PARAMETERS

 

 

 

CONTROL

UNIT

 

 

 

 

 

 

 

 

 

 

 

 

TYPE

MODE

LOFF

L-C

L-SC

rEM

CCN

MASt

CHIL_S_S

REMOTE

MASTER

START/STOP

CCN

GENERAL

 

 

 

 

 

 

 

 

 

START/STOP

CONTROL

SCHEDULE

EMERGENCY

ALARM

 

 

 

 

 

 

 

 

 

CONTACT

TYPE

MODE

SHUTDOWN

 

 

 

-

-

-

-

-

-

-

-

-

-

Enable

-

-

Off

-

-

-

-

-

-

-

-

-

-

-

Yes

-

Off

Active

 

 

 

 

 

-

-

-

-

 

-

Local

Off

 

 

Active

 

 

 

-

-

-

Unoccupied

 

-

Local

Off

 

 

 

Active

 

 

-

Off

-

-

 

-

Remote

Off

 

 

 

Active

 

 

-

-

-

Unoccupied

 

-

Remote

Off

 

 

 

 

Active

 

Disable

-

-

-

 

-

CCN

Off

 

 

 

 

Active

 

-

-

-

Unoccupied

 

-

CCN

Off

 

 

 

 

 

Active

-

-

Local

Unoccupied

 

-

Local

Off

 

 

 

 

 

Active

-

Off

Remote

-

 

-

Remote

Off

 

 

 

 

 

Active

-

-

Remote

Unoccupied

 

-

Remote

Off

 

 

 

 

 

Active

Disable

-

CCN

-

 

-

CCN

Off

 

 

 

 

 

Active

-

-

CCN

Unoccupied

 

-

CCN

Off

 

Active

 

 

 

 

-

-

-

-

Disable

No

Local

On

 

 

Active

 

 

 

-

-

-

Occupied

Disable

No

Local

On

 

 

 

Active

 

 

-

On cooling

-

Occupied

Disable

No

Remote

On

 

 

 

Active

 

 

-

On heating

-

Occupied

Disable

No

Remote

On

 

 

 

Active

 

 

-

On auto

-

Occupied

Disable

No

Remote

On

 

 

 

 

Active

 

Enable

-

-

Occupied

Disable

No

CCN

On

 

 

 

 

 

Active

-

-

Local

Occupied

Disable

No

Local

On

 

 

 

 

 

Active

-

On cooling

Remote

Occupied

Disable

No

Remote

On

 

 

 

 

 

Active

-

On heating

Remote

Occupied

Disable

No

Remote

On

 

 

 

 

 

Active

-

On auto

Remote

Occupied

Disable

No

Remote

On

 

 

 

 

 

Active

Enable

-

CCN

Occupied

Disable

No

CCN

On

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.2 - Heating/cooling/standby operation

5.2.1 - General

The heating/cooling/standby selection applies to all units. But only 30RA/RY (liquid chillers) units, controlling a boiler and 30RH/RYH (heat pumps) units can change over to heating mode. Heating/cooling control can be automatic or manual.

5.2.2 - Heating/cooling/auto selection

The table below summarises the unit heating/cooling opera- tion, based on the following parameters:

-Control type: indicates whether the unit operates in local, remote or CCN mode. See section 5.1.

-Unit on/off status: indicates whether the unit is shut down (not authorised to start) or in operation (or authorised to start).

In automatic mode the outdoor temperature determines the

-

heating/cooling/standby changeover based on the two

 

threshold values configured by the user (see Setpoint menu for

 

cooling and heating mode changeover thresholds). If the unit is in

-

standby it does not cool or heat, and no compressor can be

 

activated. The diagram below summarises the operating

 

principle in automatic mode.

-

HEATING

STANDBY

COOLING

-

 

 

 

Outdoor

 

 

 

temperature

 

Heating

Cooling

 

 

threshold*

threshold

 

Heating/cooling/auto selection in local mode: operating mode selected via the user interface. See Information menu.

Remote heating/cooling contacts: these contacts are only active if the unit is under remote control. See sections 3.6.2 and 3.6.3.

HC_SEL: this network command permits heating/ cooling/auto control, if the unit is in CCN operating mode.

Outdoor temperature: determines the operation, if the unit is in automatic heating/cooling/standby changeover mode.

*This threshold does not apply to cooling only units that do not control a boiler.