Friedrich racservmn service manual Performance Evaporator AIR Operating Electrical Breaker Data

Page 7

PERFORMANCE

EVAPORATOR AIR

OPERATING

ELECTRICAL

R-22

BREAKER

DATA*

TEMP. DEG. F.

PRESSURES

RATINGS

REFRIG.

FUSE

Cooling

 

 

 

 

 

 

 

 

Discharge

Temp.

Suction

Discharge

Amps

Locked

Charge in

60 Hertz

 

Air

Drop F.

 

 

 

Rotar Amp

OZ.

Amps

 

 

 

 

 

 

 

 

 

ES12J33B-A

58

22

82

265

5.76.6

26.3

28

20

ES16J33A-A

53

27

77

269

7.5/8.0

42.'0

30

20

EM18J34B-A

55

25

71

267

8.6/9.2

42.'0

40.5

30

EL25J35-A

55

25

75

284

11.5/12.6

61.'0

48.5

30

EL35J35-A

52

28

72

317

18/20

94.'0

60

30

EL35J35-B

52

28

72

317

18/20

94.'0

60

30

 

 

 

 

 

 

 

 

 

PERFORMANCE

Heat Rise

 

 

 

 

 

 

 

DATA heating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ES12J33B-A

30.5

 

 

 

16/14.7

 

 

 

ES16J33A-A

30.5

 

 

 

16/14.7

 

 

 

EM18J34B-A

28.3

 

 

 

19.5/17

 

 

 

EL25J35-A

28.6

 

 

 

24/22/4

 

 

 

EL35J35-A

22.9

 

 

 

24/22.4

 

 

 

EL35J35-B

22.9

 

 

 

24/22.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KS-KM PERFORMANCE DATA

 

 

 

 

 

 

 

 

 

DATA*

EVAPORATOR AIR

OPERATING

ELECTRICAL

R-22

BREAKER

Cooling

TEMP. DEG. F.

PRESSURES

RATINGS

REFRIG.

FUSE

 

Discharge

Temp

 

 

Amps

Locked

Charge in

60 Herts

 

Air

Drop F.

 

 

 

Rotar Amp

OZ.

Amps

KS10E10-A

61

19

82

248

9.1

48.3

26.08

15

KS10J10-B

61

19

80

263

9.1

48.3

26.88

15

KS12E10-A

57

23

83

271

10.8

54.'0

28

15

KS12J10B-A

57

23

84

268

10.8

54.'0

28

15

KS15J10-A

55.78

23.52

77

279

12.'0

67.'0

29.5

15

KS12J30B-A

57

23

76

285

6.2

26.'0

30.08

15

KS18J30-A

56

24

72

293

8.7

48

48

15

KM20J30-A

55

24

70

279

9.9

48

48

15

KM24J30-A

55

25

68

301

15.'0

71.'0

54.08

15

 

 

 

 

 

 

 

 

 

*Rating Conditions: 80 degree F. Room Air Temperature and 50% Relative Humidity with 95 degree F. Outside Air Temperature at 40% Relative Humidity.

7

Image 7
Contents 2003 Table of Contents RAC Serial Number Identification Guide 1st Digit Function00001 Page Data Evaporator AIR Operating Electrical Breaker Pressures Ratings Refrig Fuse Performance Evaporator AIR Operating Electrical Breaker Data SS10J10AR-A TEMP. DEG. F Pressures Ratings SC06H10E HeatingBtuh WY09A33F-A WY12A33F-A HeatingAmps Refrigeration System Sequence of Operation Grounding Wire SizeFuse/Circuit BreakerWinding Test Thermal Overload ExternalChecking Compressor Efficiency FAN Motor Terminal Overload TestTerminal Overload Internal Checking the Internal OverloadResistor System Control Panel System Control Panel KQ Models Only- See FigureEQ Model Only See Figure System Control Panel YQ Model Only System Control Switch Test System Control Switch WE & WY Models See FigureSystem Control Panel See Figure System Control Switch KS, SS, KM, SM, SL Models See FigureHeat Pump & Electric Heat Models See Figure System Control SwitchSmart Center Electronic Control Center To SET Mode of OperationTo Adjust Temperature To Adjust FAN SpeedTo SET Hour Clock To SET the TimerTesting the Electronic Control Testing the Electronic Control Error Code ListingsThermostat Models ES, YS, EM, YM, EL, YL See Figure TestThermostat SQ & KQ Models See Figure Thermostat YQ Model Only See FigureDefrost Thermostat Heat Pump Models Only Thermostat AdjustmentThermostat Bulb Location CAPACITOR, RUN See Figure Defrost Bulb Location Heat Pump Models OnlyCapacitor Test Heat Pumps Reversing Valve See Figure Check Valve OperationSolenoid Coil Heat Pump Models Only See Figure Testing Reversing ValveTo Test Equipment Required VALVE, Drain PAN See FigureHeating Element See Figure Sealed Refrigeration System RepairsEquipment Must be Capable Hermetic Component ReplacementSpecial Procedure in the Case Compressor Motor Burnout Rotary Compressor Special Troubleshooting and ServiceMethod of Charging Undercharged Refrigerant SystemsOvercharged Refrigerant Systems Restricted Refrigerant System Routine Maintenance Troubleshooting Touch Test Chart To Service Reversing Valves Problem To Correct Troubleshooting CoolingProblem Possible Cause To Correct Cycles Problem Possible Cause To Correct Troubleshooting Heating Heat pumps Problem Possible Cause To Correct Off and the electric element is energized Troubleshooting Heating Cooling/Electric Models Troubleshooting Chart Cooling YES System Cools When Heating is DesiredModels SQ06J10B-B, SQ06J10B-A, SQ08J10C-A, SQ08J10D-A Models KQ08J10B-1, KQ08J10B-A, KQ08J10C-A Schematic YQ06J10B-A ModelModel SC06H10D 619-405-06 Alternate SL28J30B-A, SL35J30-A, SL35J30-BConductor Or Brown RED Blue To Capacitor Bracket Wiring Diagram YS12J33-A, YM18J34B-A, YL24J35C-A Model EQ08J11-A, EQ08J11-B IDT Ovld Neutral WE09A33E-B, WE12A33E-A, WE15A33-A WY09A33F-A, WY12A33G-A Checking Room Temperature Testing The Electronic Control XQ Boards & QME BoardsFriedrich AIR Conditioning CO

racservmn specifications

Friedrich Racervmn is an innovative name in the realm of precision engineering, making significant strides in the development of advanced technologies for various industries. This company stands out due to its commitment to creating high-quality, reliable, and efficient products that cater to the diverse needs of its clientele.

One of the main features of Friedrich Racervmn is its focus on research and development. The company invests heavily in R&D to push the boundaries of what is technically possible. This dedication results in the continuous improvement of their product line and the introduction of cutting-edge solutions that leverage the latest advancements in technology.

Among the distinctive technologies used by Friedrich Racervmn is their proprietary manufacturing process, which integrates automation and robotics to enhance efficiency and precision. This not only speeds up production times but also ensures that the products maintain a consistently high quality. The use of Computer Numerical Control (CNC) machines in their processes allows for intricate designs and complex geometries that meet rigorous industry standards.

Moreover, Friedrich Racervmn utilizes innovative materials in their products to ensure durability and performance under various conditions. These materials are selected based on their specific properties, such as strength, weight, and resistance to environmental factors, ensuring that the final output exceeds customer expectations.

Another hallmark of Friedrich Racervmn is their commitment to sustainability. The company actively seeks ways to minimize its environmental footprint by optimizing resource use and incorporating eco-friendly practices throughout its manufacturing processes. This is reflected in their efforts to design products that are not only high-performing but also energy-efficient, helping customers reduce their carbon emissions.

Friedrich Racervmn’s customer service stands out as well. Their team is dedicated to providing exceptional support, ensuring that clients receive personalized attention and solutions tailored to their unique needs. This customer-centric approach is a fundamental part of their philosophy and has contributed to building strong and lasting relationships within the industry.

In summary, Friedrich Racervmn is a leader in precision engineering, recognized for its advanced technologies, innovative manufacturing processes, commitment to sustainability, and outstanding customer service. The company’s focus on quality and innovation positions it as a vital player in the modern industrial landscape, continuously pushing the envelope toward a more technologically advanced and environmentally conscious future.