Chief Manufacturing SMA-602 Disassemble Pipe Adapter Assembly, Attach Main Plate to SL-151 Lift

Page 5

Installation Instructions

 

 

 

SMA-602

Assembly And Installation

 

 

 

 

The SMA-602 pipe adapter assembly was designed to attach

 

 

 

the UL-Listed SL151 lift (not included) to a 1-1/2" NPT or NPSM

1

(C) x 3

 

following ANSI/ASME B1.20.1 (Schedule 40, 0.154" minimum

(underside of SL-151)

thickness steel or aluminum - ASTM B221) threaded extension

 

(E) x 3

 

 

column (not included). A minimum of four threads must be

 

 

 

engaged.

 

 

 

 

Disassemble Pipe Adapter Assembly

 

 

 

1. Unscrew four hex nuts on pipe adapter assembly (A). (See

 

 

 

 

Figure 1)

 

 

 

 

2. Remove top and bottom slide assembly plates from main

 

 

 

 

plate. (See Figure 1)

 

 

 

 

 

1

hex nuts x 4

 

 

 

 

 

top slide plate

 

 

 

 

 

main plate

 

 

 

 

 

 

 

Figure 2

 

 

 

 

2

(D) x 3

 

 

 

 

 

(E) x 3

 

 

 

bottom slide plate

 

Figure 3

 

 

 

(underneath)

 

 

 

 

 

 

 

 

Figure 1

 

4

(D) x 3

 

 

 

 

 

Attach Main Plate to SL-151 Lift

 

 

 

1. Insert a 3/8-16 x 3 1/2" hex head tap bolt (C) through a 3/8"

 

 

 

 

washer (E) and through one of three holes on top of SL-151

 

 

 

 

lift. (See Figure 2)

 

 

 

 

2.

Install a 3/8" washer (E) and a 3/8-16" hex nut (D) over tap

 

 

 

 

bolt. (See Figure 3)

 

 

 

 

3. Repeat Steps 1-2 for other two holes on SL-151 lift.

 

 

 

4.

Thread each nut completely on bolts. (See Figure 4)

 

 

 

Figure 4

5

Image 5
Contents SMA-602 Disclaimer Important Safety InstructionsInstallation Instructions SMA-602 Parts Tools Required for InstallationAttach Main Plate to SL-151 Lift Disassemble Pipe Adapter AssemblyAttaching Main Plate and SL-151 to Ceiling Pipe Yaw Adjustment AdjustmentsHeight Adjustment Projector InstallationUSA/International