Chief Manufacturing SMA-602 Attaching Main Plate and SL-151 to Ceiling Pipe

Page 6

SMA-602

Installation Instructions

5.Partially thread a 3/8-16" hex nut (D) onto each of three 3/ 8-16 x 3 1/2" hex head tap bolts (C). (See Figure 5)

6.Place a 3/8" washer (E) over each hex nut. (See Figure 5)

7.Place main plate over three bolts lining up the holes on the outside edge of the plate with the screws. (See Figure 5)

8.Place another 3/8" washer (E) and 3/8-16" hex nut (D) over each bolt. (See Figure 5)

 

 

main plate

 

5

(D) x 3

8

(D) x 3

 

(E) x 3

(E) x 3

 

 

 

 

Figure 5

9.Secure main plate near top of bolts by threading nuts together. Make sure to leave plenty of space between plate and SL-151 to allow for easy access in later steps. (See Figure 6)

Attaching Main Plate and SL-151 to Ceiling Pipe

IMPORTANT ! : Only attach SMA-602 to UL Listed Chief ceiling mount SL151.

IMPORTANT ! : These installation instructions assume that a 1-1/2" NPT or NPSM following ANSI/ASME B1.20.1 (Schedule 40, 0.154" minimum thickness aluminum - ASTM B221) threaded extension column (not included) has been properly installed and is in place.

1.Thread top slide plate assembly onto ceiling pipe until it cannot be tightened any further. (See Figure 7)

2.Adjust top slide plate assembly back clockwise until set screw hole is facing target. (See Figure 7)

IMPORTANT ! : When SMA-602 is properly positioned, the set screw access hole should be pointing directly at target.

3.Insert 5/16-18 x 1/4" set screw (B) into access hole to secure top slide plate to ceiling pipe. (See Figure 7)

 

ceiling pipe

1

 

 

top slide plate

 

assembly

2

 

3

(B)

Figure 7

9

leave space

Figure 6

WARNING: Exceeding the weight capacity can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the combined weight of all components located between the SMA-602 up to (and including) the projector does not exceed 105 lbs (47.6 kg).

WARNING: Improper installation can result in serious personal injury or damage to equipment! The SL-151 projector mount weighs in excess of 50 lbs! Use either a mechanical lifting device or at least two people to lift and install SL-151.

4.Lift main plate and attached SL-151 underneath top slide plate making sure the four slots on each plate are perpendicular to each other. (See Figure 8)

5.Place bottom slide plate directly underneath main plate inserting four bolts through four slots in main plate.

6.Insert four bolts up through four slots on top slide plate and secure using the four hex nuts removed in Step 1 of Disassemble Pipe Adapter Assembly. (See Figure 8)

6

Image 6
Contents SMA-602 Important Safety Instructions DisclaimerInstallation Instructions SMA-602 Tools Required for Installation PartsDisassemble Pipe Adapter Assembly Attach Main Plate to SL-151 LiftAttaching Main Plate and SL-151 to Ceiling Pipe Height Adjustment AdjustmentsYaw Adjustment Projector InstallationUSA/International