Friedrich PTAC Wall Sleeve Installation Instructions Pxws, Typical Wall Sleeve Installation

Page 7

920-087-02 (9-03)

Wall Sleeve Installation Instructions (PXWS)

NOTE: Insure that the unit is only installed in a wall structurally adequate to support the unit including the sleeve, chassis and accessories. If the sleeve projects more than 8" into the room, a subbase or other means of support MUST be used. Please read these instructions completely before attempting installation.

Figure 5

Typical Wall Sleeve Installation

 

 

 

 

.

 

421⁄4"

min

 

 

cm)

 

 

3

 

 

 

.

 

 

 

Lintel to support masonry walls

(107

 

 

 

 

 

 

 

10"

 

 

 

 

(25.4 cm)

 

 

 

 

max.

 

 

 

 

 

 

 

133⁄4"

 

 

(34.

 

 

 

 

9

cm)

 

 

 

 

Electrical receptacle

 

 

 

 

Wall opening

Wall sleeve

 

 

161⁄4"

 

Electrical receptacle

(41.3 cm)

.

 

 

n

 

 

mi

(127

cm)

 

 

50"

 

 

Insulation

Insulation

Smooth side of screw clip facing into room

For Deep Wall Installation See Section II

The following instructions apply ONLY to walls less than 13 1/4" in depth.

1.From inside the building, position the wall sleeve in the opening and push it through the wall so it protrudes at least 1/4" on the outside, note Figure 5.

2.Position the wall sleeve with a slight tilt towards the outside to facilitate condensate drainage. It should be level side-to-side and the front should be 1/4 bubble higher than the back. DO NOT allow any pitch toward the inside.

Electrical shock hazard.

Turn electric power OFF at the fuse box or service panel before making any electrical connections and ensure a proper ground connection is made before connecting line voltage. Failure to do so can result in property damage, personal injury and/or death.

7

Image 7
Contents Standard Remote Thermostat Seacoast Protected WallMaster PtacTypical Unit Components Table of ContentsModel Number Code Building Elevation Ptac Installation RecommendationsDrain Kit Location and Installation Installation Instructions PXDR10 Drain KitInternal Drain optional for new construction PXDR1O External Drain for new construction or unit replacementDrain Kit Installation Drain Tube Installation Cover Plate InstallationTypical Wall Sleeve Installation Wall Sleeve Installation Instructions PxwsLintel Installation DimensionsExtension Installation Section II Deep Wall Installation PxweWall Sleeve Extension Sealant Locations Standard Grille Installation Instructions Model Pxga Standard GrilleElectrical Rating Tables Installation ChecklistSuffocation hazard Keep bag away from babies and children Section III Chassis InstallationScrew clips Chassis Mounting screw Chassis flange Cooling only Model HEAT/COOL Model Temperature Limiting ThermostatStandard Unit Operation Standard Unit Control PanelHeating Control heat pumps and emergency heat operation Fan Cycle SwitchFresh Air Vent Control Air Discharge Grille Start-up ChecklistHoneywell Thermostat Terminal Designation Appendix a Remote Thermostat Unit InstallationSimplified Wiring Example Manual Changeover ThermostatAuto Changeover Thermostat Remote Thermostat InstallationAppendix a Remote Thermostat 208V OperationLine Voltage Connections Appendix B Electrical Wiring for 265 Volt ModelsRoutine Maintenance Maintenance and Inspection Troubleshooting Guide Basic Troubleshooting TechniquesModel Number Description Photo Friedrich Ptac AccessoriesDesignatordescription Model Number DescriptionRevised 8/01

PTAC specifications

Friedrich PTAC (Packaged Terminal Air Conditioner) units are a popular choice for heating and cooling in commercial and residential spaces, thanks to their efficient design and reliable performance. Friedrich, a company with a long-standing reputation in the HVAC industry, offers a range of PTAC units characterized by advanced features and technologies that set them apart from traditional cooling systems.

One of the main features of Friedrich PTAC units is their high energy efficiency. Many of their models are Energy Star certified, which means they meet the stringent energy efficiency guidelines set by the U.S. Environmental Protection Agency. This efficiency translates into lower energy costs for users and reduced environmental impact, making them an excellent choice for energy-conscious consumers.

Friedrich PTAC units are equipped with advanced technologies that enhance their functionality. For instance, many units come with a built-in Wi-Fi option, enabling remote control through mobile devices. This feature allows users to monitor and adjust temperature settings, schedules, and modes from anywhere, providing convenience and ensuring energy is not wasted when spaces are unoccupied.

The design of Friedrich PTAC units also emphasizes ease of installation and maintenance. These units are designed to fit into existing wall sleeves, making replacement straightforward without significant structural modifications. Furthermore, their ease of access for servicing ensures that maintenance tasks can be performed quickly, reducing downtime and improving longevity.

Another key characteristic of Friedrich PTAC units is their robust construction. Built to withstand varying conditions, these units feature durable materials that ensure long-term reliability. Many models incorporate advanced sound-dampening technology, creating a quieter operation that enhances comfort, especially in residential applications.

Friedrich’s commitment to innovation is evident in its product line, offering various options to meet different climate requirements and user preferences. The units can provide both heating and cooling, making them versatile for year-round use. Additionally, they are available in various BTU capacities, allowing customers to select the appropriate model for their specific space needs.

Overall, Friedrich PTAC units are recognized for their efficiency, technological advancements, ease of installation, and sturdy design, making them an excellent choice for both commercial and residential applications where reliable climate control is needed.