Friedrich Comprehensive PTAC Installation Manual and Guide for Installers and Used Units

Page 8

920-087-02 (9-03)

Figure 6

Dimensions

1⁄4"

A (6.4 cm) min.

133⁄4"

(35 cm)

B

Wall

 

A

 

B

Dimension*

Allow

Allow for floor finishing

 

for wall

 

 

 

finishing

 

 

 

(Minimum)

Min.

Max

No Accessories

1⁄4"

1⁄4"

 

 

(6.4 mm)*

(6.4 mm)

---

With Subbase

13⁄4"

31⁄2"

5"

 

(4.5 cm)

(8.9cm)

(12.7cm)

With Lateral Duct

3⁄4"

1⁄4"

 

 

(1.9 cm)

(6.4 mm)

---

*If more than one accessory is to be used, use the maximum dimension. If the wall thickness is more than 133⁄4" (35cm) - (A + 1⁄4" [6.4 mm]), a sleeve extension must be used.

3.Drill two 3/16" holes through each side of the sleeve approximately 4" from top and 4" from bottom of sleeve. Screw four #10 x 1" screws (included) or appropriate fasteners for your installation, through the holes in the sides of the wall sleeve.

4.Apply sealant around the wall sleeve where it projects through the inside and outside wall surfaces. Apply the sealant to the screw heads or the tops of the fasteners used in Step #3.

NOTE: When sealing the sleeve on the outside of the building, be careful NOT to let the sealant block the two condensate drain holes or the four overflow slots at the bottom flange of the sleeve.

5.If the chassis and exterior grille are to be installed later, leave the weatherboard and center support in place, otherwise remove and dispose of them.

6.Provide a support lintel if the wall sleeve is installed in a concrete or masonry wall. (See Figure 7.)

Figure 7

Lintel Installation

Main studs

Jack studs

Lintel

Main studs

Jack studs

Mounting screw holes

No holes in bottom of wall sleeve unless drain kit is used

NOTE: Construct wall opening to comply with all applicable building codes.

8

Image 8
Contents WallMaster Ptac Standard Remote Thermostat Seacoast ProtectedTable of Contents Typical Unit ComponentsModel Number Code Ptac Installation Recommendations Building ElevationInternal Drain optional for new construction Installation Instructions PXDR10 Drain KitDrain Kit Location and Installation External Drain for new construction or unit replacement Drain Kit InstallationDrain Tube Installation Cover Plate Installation PXDR1OWall Sleeve Installation Instructions Pxws Typical Wall Sleeve InstallationDimensions Lintel InstallationWall Sleeve Extension Sealant Locations Section II Deep Wall Installation PxweExtension Installation Installation Instructions Model Pxga Standard Grille Standard GrilleInstallation Checklist Electrical Rating TablesSection III Chassis Installation Suffocation hazard Keep bag away from babies and childrenScrew clips Chassis Mounting screw Chassis flange Temperature Limiting Thermostat Standard Unit OperationStandard Unit Control Panel Cooling only Model HEAT/COOL ModelFresh Air Vent Control Fan Cycle SwitchHeating Control heat pumps and emergency heat operation Start-up Checklist Air Discharge GrilleAppendix a Remote Thermostat Unit Installation Simplified Wiring ExampleManual Changeover Thermostat Honeywell Thermostat Terminal DesignationRemote Thermostat Installation Appendix aRemote Thermostat 208V Operation Auto Changeover ThermostatAppendix B Electrical Wiring for 265 Volt Models Line Voltage ConnectionsRoutine Maintenance Basic Troubleshooting Techniques Maintenance and Inspection Troubleshooting GuideFriedrich Ptac Accessories Model Number Description PhotoModel Number Description DesignatordescriptionRevised 8/01

PTAC specifications

Friedrich PTAC (Packaged Terminal Air Conditioner) units are a popular choice for heating and cooling in commercial and residential spaces, thanks to their efficient design and reliable performance. Friedrich, a company with a long-standing reputation in the HVAC industry, offers a range of PTAC units characterized by advanced features and technologies that set them apart from traditional cooling systems.

One of the main features of Friedrich PTAC units is their high energy efficiency. Many of their models are Energy Star certified, which means they meet the stringent energy efficiency guidelines set by the U.S. Environmental Protection Agency. This efficiency translates into lower energy costs for users and reduced environmental impact, making them an excellent choice for energy-conscious consumers.

Friedrich PTAC units are equipped with advanced technologies that enhance their functionality. For instance, many units come with a built-in Wi-Fi option, enabling remote control through mobile devices. This feature allows users to monitor and adjust temperature settings, schedules, and modes from anywhere, providing convenience and ensuring energy is not wasted when spaces are unoccupied.

The design of Friedrich PTAC units also emphasizes ease of installation and maintenance. These units are designed to fit into existing wall sleeves, making replacement straightforward without significant structural modifications. Furthermore, their ease of access for servicing ensures that maintenance tasks can be performed quickly, reducing downtime and improving longevity.

Another key characteristic of Friedrich PTAC units is their robust construction. Built to withstand varying conditions, these units feature durable materials that ensure long-term reliability. Many models incorporate advanced sound-dampening technology, creating a quieter operation that enhances comfort, especially in residential applications.

Friedrich’s commitment to innovation is evident in its product line, offering various options to meet different climate requirements and user preferences. The units can provide both heating and cooling, making them versatile for year-round use. Additionally, they are available in various BTU capacities, allowing customers to select the appropriate model for their specific space needs.

Overall, Friedrich PTAC units are recognized for their efficiency, technological advancements, ease of installation, and sturdy design, making them an excellent choice for both commercial and residential applications where reliable climate control is needed.