Friedrich R-410A service manual Hazardgard Application, Ideal applications

Page 7

HAZARDGARD APPLICATION

UL Listed for use in Class I, Division 2, Groups A, B, C and D hazardous locations.

Hazardgard is specically designed to cool living qu arters, storage areas and other enclosures situated in hazardous locations, where specic volatile ammable liquids or gases are handled or used withi n enclosed containers or systems.

For more than 30 years, the Friedrich Hazardgard has endured some of the toughest and most unforgiving operating conditions imaginable. Timetested in the eld where it counts, Hazardgard is trusted b y professionals who have to get the job done. Robust engineering with design details like 33% thicker

ns extend the life of the coil. Diamonblue Technology, our anticorrosive treatment, provides added endurance and protection in coastal or corrosive environments.

Ideal applications

Oe oil rigs, one oil company

Ofce complexes where methane is a

ofes and re

byproduct

Petrochemical sites and propane llup

Hazardous materials storage

stations

 

Paint and varnish storage or processing

 

plants

 

Grain alcohol processors or storage sites

 

Plant areas using strong solvents or

 

chemicals

 

Munitions plants or armories

 

PVC or plastics plants and processing

 

points

 

Recycling plants

 

Furniture retripping

 

workshops

 

Fertilizer plants

 

HAZARDOUS DUTY

6

Image 7
Contents Hazardous Duty Room Air Conditioner Table Of Contents Electrical Hazards Your safety and the safety of others are very importantMechanical Hazards Refrigeration System HazardsFire Damage Hazards IntroductionWater Damage Hazards Unit Identification 15 M 3 0 a aIdeal applications Hazardgard ApplicationCooling Performance Data Specifications and Performance DataElectric Shock Hazard Electrical DataFire Hazard Control Panel Hazardgard Special FeaturesMechanical components Component DefinitionsCapacitor Check with Capacitor Analyzer Component TestingCapacitor Connections High Pressure Hazard ThermostatRefrigeration system under high pressure 410A Sealed System Repair ConsiderationsRisk of Electric Shock 410A Sealed Refrigeration System RepairsEquipment Required Equipment Must be CapableBurn Hazard Method Of Charging / RepairsFreeze Hazard Overcharged Refrigerant Systems Undercharged Refrigerant SystemsRestricted Refrigerant System Compressor Checks High Temperatures Compressor ReplacementSingle Phase Resistance Test Recommended procedure for compressor replacementExplosion Hazard Routine Maintenance Front Cover Sleeve / DrainClearances Compressor Indoor TemperaturesOutdoor Temperature ElectricalTroubleshooting Only. Cycles on Problem Possible Cause SH15M30 SH20M30 Electromechanical Control Cool only ModelsLimited ONE Year Parts Warranty Hazardgard Room AIR Conditioners Limited WarrantyTechnical Support Contact Information Page Friedrich AIR Conditioning CO
Related manuals
Manual 32 pages 34.87 Kb Manual 47 pages 33.75 Kb Manual 16 pages 9.01 Kb Manual 87 pages 18.35 Kb

R-410A specifications

Friedrich R-410A is an advanced refrigerant widely used in HVAC (Heating, Ventilation, and Air Conditioning) systems, known for its high efficiency and environmental friendliness. As a hydrofluorocarbon (HFC) blend, R-410A has become the preferred alternative to R-22, which is being phased out due to its ozone-depleting potential. One of the main features of R-410A is its high latent heat of vaporization, which allows for efficient heat transfer and improved cooling performance in air conditioning units.

Technologically, R-410A operates at higher pressures than older refrigerants, meaning systems designed for R-410A need to be built with more robust components to safely handle these pressures. This results in a more compact system design that offers enhanced performance and reliability. The dual-component nature of R-410A—composed of difluoromethane (R-32) and pentafluoroethane (R-125)—provides an optimal balance of thermodynamic properties, leading to superior energy efficiency, especially in variable speed applications.

In terms of characteristics, R-410A has a higher cooling capacity, which enables HVAC systems to effectively cool larger spaces or run more efficiently when cooling smaller areas. The refrigerant is non-toxic and non-flammable, which enhances safety during its use. In addition, R-410A has a lower global warming potential relative to other refrigerants, making it a more environmentally responsible choice for modern cooling systems.

Moreover, R-410A systems typically require less refrigerant charge due to their efficiency, contributing to reduced greenhouse gas emissions. The adoption of R-410A aligns with regulatory trends aimed at minimizing the environmental impact of refrigerants in cooling applications.

Overall, the Friedrich R-410A refrigerant embodies a combination of technology and environmental stewardship, making it a cornerstone of contemporary HVAC design. Its ability to provide effective and energy-efficient cooling solutions while being compliant with modern environmental regulations positions R-410A as the refrigerant of choice for engineers and installers focused on sustainability and performance in air conditioning systems.