SWING OPERATION

Begin air conditioner operation before performing this procedure.

To select Vertical airflow SWING Operation

Press the AIR FLOW DIRECTION VERTICAL SWING button.

The SWING indicator lamp (VERTICAL SWING) (orange) will light.

In this mode, the UP/DOWN air direction flaps will swing automatically to direct the air flow both up and down.

To Stop Vertical airflow SWING Operation

Press the AIR FLOW DIRECTION VERTICAL SWING button once again.

The SWING indicator lamp (VERTICAL SWING) will go out.

 

Airflow direction will return to the setting before swing was begun.

Example: When set to vertical swing

 

About Swing Operation

The range of swing is relative to the currently set airflow direction.

Air flow direction set

Range of swing

1

1 to 3

2

1 to 4

3

2 to 5

4

3 to 6

5

4 to 7

6

5 to 7

7

1 to 7 (All range)

Air direction range (See page 10, Fig. 7)

If the swing range is not as desired, use the remote con- trol unit’s AIR FLOW DIRECTION VERTICAL SET button to change the range of swing.

The SWING operation may stop temporarily when the air conditioner’s fan is not operating, or when operating at very low speeds.

During use of the Cooling and Dry modes, do not set the air UP/DOWN direction flaps, in the Heating range (5 to 7) for long periods of time, since water vapor may con- dense near the outlet louvers and drops of water may drip from the air conditioner.

To select Horizontal airflow SWING Operation

Press the AIR FLOW DIRECTION HORIZONTAL SWING button.

The SWING indicator lamp (HORIZONTAL SWING) (orange) will light.

In this mode, the RIGHT/LEFT air direction louvers will swing automatically to direct the airflow both right and left.

To Stop Horizontal airflow SWING Operation

Press the AIR FLOW DIRECTION HORIZONTAL SWING button once again.

The SWING indicator lamp (HORIZONTAL SWING) will go out.

Example: When set to horizontal swing

Airflow direction will return to the setting before swing was begun.

About Swing Operation

The range of swing is relative to the currently set airflow direction.

Air flow direction set

Range of swing

1

1 to 5 (All range)

2

1 to 3

3

2 to 4

4

3 to 5

5

1 to 5 (All range)

 

 

Air direction range (See page 10, Fig. 8)

If the swing range is not as desired, use the remote con- trol unit’s AIR FLOW DIRECTION HORIZONTAL SET but- ton to change the range of swing.

The SWING operation may stop temporarily when the air conditioner’s fan is not operating, or when operating at very low speeds.

En-11

9359944072-01_OM_en.p65

11

1/21/10, 1:51 PM

Image 12
Contents Floor CONSOLE/ Under Ceiling Dual Type Contents Safety PrecautionsFeatures and Functions Automatic OperationName of Parts En-3Vertical SET button Vertical Swing buttonHorizontal SET button Preparation To Select Mode Operation Press the START/STOP button OperationTo Set the Thermostat Press the SET TEMP. buttons To Set the Fan Speed Press the FAN Control buttonAbout Mode Operation Heat & Cool Model Reverse CycleHeating DryTimer Operation Timer operationTo Use the Program timer Press the START/STOP button Set the desired times for OFF timer and on timerSleep Timer Operation To Change the Timer SettingsAbout the Sleep timer Manual Auto OperationAdjusting the Direction of AIR Circulation Types of Air flow Direction SettingSwing Operation About Swing OperationAir flow direction set Range of swing Cleaning and Care Clean the air filtersPull the air filters upward to remove them Re-attach the air filters to the intake grilleSelecting the Remote Control Unit Signal Code Troubleshooting Symptom ProblemWhen Indoor and Outdoor Temperature are High Operating TipsOperation and Performance Heating PerformanceEvent of Power Interruption Auto RestartMulti-type Air conditioner Simultaneous Use of Multiple UnitsEn-17 9359944072-01OMes.p65 21/10, 156 PM 9359944072-01OMes.p65 21/10, 156 PM