Friedrich PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS manual Extended Heating Performance

Page 3

Extended Cooling Performance, PE07/09/12/15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Dry Bulb Temp. (°F at 40% R.H.)

 

 

 

 

 

 

 

75

 

 

85

 

 

95

 

 

105

 

 

115

 

 

 

 

 

 

 

Indoor Wet Bulb Temp. (°F at 80°F D.B.)

 

 

 

 

 

 

72

67

62

72

67

62

72

67

62

72

67

62

72

67

62

 

Btuh

8820

8483

7853

8400

7920

7305

8070

7500

6638

7560

6713

5918

6728

5790

5115

PE07

Watts

502

510

515

547

552

559

615

615

615

665

664

666

725

725

728

Amps

2.5

2.5

2.5

2.7

2.7

2.7

3

3.00

3

3.2

3.2

3.2

3.5

3.5

3.5

 

 

SHR

0.52

0.71

0.95

0.53

0.73

0.97

0.53

0.76

0.98

0.55

0.8

0.98

0.57

0.86

0.97

 

Btuh

10819

10405

9632

10304

9715

8961

9899

9200

8142

9274

8234

7259

8252

7102

6274

PE09

Watts

664

675

682

724

731

740

814

814

814

880

879

882

960

960

964

Amps

3.2

3.2

3.3

3.5

3.5

3.5

3.9

3.90

3.9

4.2

4.2

4.2

4.6

4.6

4.6

 

 

SHR

0.51

0.70

0.94

0.52

0.72

0.96

0.53

0.75

0.96

0.54

0.79

0.97

0.57

0.84

0.96

 

Btuh

14112

13572

12564

13440

12672

11688

12912

12000

10620

12096

10740

9468

10764

9264

8184

PE12

Watts

915

929

939

997

1007

1019

1121

1091

1121

1212

1211

1214

1322

1322

1327

Amps

4.2

4.2

4.3

4.5

4.6

4.6

5.1

5.10

5.1

5.5

5.5

5.5

6

6

6

 

 

SHR

0.49

0.67

0.9

0.5

0.7

0.92

0.51

0.72

0.92

0.52

0.76

0.93

0.54

0.81

0.92

 

Btuh

17640

16965

15705

16800

15840

14610

16140

15000

13275

15120

13425

11835

13455

11580

10230

PE15

Watts

1288

1309

1323

1404

1418

1435

1579

1579

1579

1707

1705

1710

1862

1862

1870

Amps

5.5

5.5

5.6

5.9

5.9

5.9

6.6

6.60

6.6

7.1

7.1

7.1

7.7

7.7

7.8

 

 

SHR

0.51

0.70

0.94

0.52

0.72

0.96

0.53

0.72

0.96

0.54

0.79

0.97

0.57

0.84

0.96

 

 

 

 

 

 

 

 

RATING POINT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ARI 310/380

 

 

 

 

 

 

Extended Cooling Performance, PH07/09/12/15

 

 

 

 

 

 

Outdoor Dry Bulb Temp. (°F at 40% R.H.)

 

 

 

 

 

 

 

75

 

 

85

 

 

95

 

 

105

 

 

115

 

 

 

 

 

 

 

Indoor Wet Bulb Temp. (°F at 80°F D.B.)

 

 

 

 

 

 

72

67

62

72

67

62

72

67

62

72

67

62

72

67

62

 

Btuh

8820

8483

7853

8400

7920

7305

8070

7200

6638

7560

6713

5918

6728

5790

5115

PH07

Watts

502

510

515

547

552

559

615

595

615

665

664

666

725

725

728

Amps

2.5

2.5

2.5

2.7

2.7

2.7

3

3.00

3

3.2

3.2

3.2

3.5

3.5

3.5

 

 

SHR

0.52

0.71

0.95

0.53

0.73

0.97

0.53

0.76

0.98

0.55

0.8

0.98

0.57

0.86

0.97

 

Btuh

10819

10405

9632

10304

9715

8961

9899

9100

8142

9274

8234

7259

8252

7102

6274

PH09

Watts

657

667

675

716

723

732

805

805

805

870

869

872

949

949

953

Amps

3.2

3.2

3.3

3.5

3.5

3.5

3.9

3.90

3.9

4.2

4.2

4.2

4.6

4.6

4.6

 

 

SHR

0.51

0.7

0.94

0.52

0.72

0.96

0.53

0.75

0.96

0.54

0.79

0.97

0.57

0.84

0.96

 

Btuh

14112

13572

12564

13440

12672

11688

12912

12000

10620

12096

10740

9468

10764

9264

8184

PH12

Watts

915

929

939

997

1007

1019

1121

1121

1121

1212

1211

1214

1322

1322

1327

Amps

4.2

4.2

4.3

4.5

4.6

4.6

5.1

5.10

5.1

5.5

5.5

5.5

6

6

6

 

 

SHR

0.49

0.67

0.9

0.5

0.7

0.92

0.51

0.72

0.92

0.52

0.76

0.93

0.54

0.81

0.92

 

Btuh

17640

16965

15705

16800

15840

14610

16140

14700

13275

15120

13425

11835

13455

11580

10230

PH15

Watts

1288

1309

1323

1404

1418

1435

1579

1581

1579

1707

1705

1710

1862

1862

1870

Amps

5.5

5.5

5.6

5.9

5.9

5.9

6.6

6.6

6.6

7.1

7.1

7.1

7.7

7.7

7.8

 

 

SHR

0.51

0.70

0.94

0.52

0.72

0.96

0.53

0.72

0.96

0.54

0.79

0.97

0.57

0.84

0.96

 

 

 

 

 

 

 

 

RATING POINT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ARI 310/380

 

 

 

 

 

 

Extended Heating Performance

 

 

 

 

Outdoor Dry Bulb Temp. (°F)

 

 

 

 

37

42

 

47

 

52

57

PH07

Btuh

5366

5663

 

6400

 

7053

7789

Watts

536

545

 

568

 

577

610

 

Amps

2.5

2.6

 

2.6

 

2.7

2.8

 

Btuh

6005

6399

 

8100

 

8647

9245

PH09

Watts

666

676

 

742

 

747

757

 

Amps

3.1

3.1

 

3.2

 

3.2

3.3

PH12

Btuh

7799

8611

 

10800

 

11383

12349

Watts

893

927

 

1021

 

1051

1085

 

Amps

3.8

3.9

 

4.3

 

4.5

4.7

 

Btuh

10688

11013

 

13500

 

14769

16180

PH15

Watts

1301

1318

 

1413

 

1497

1564

 

Amps

5.3

5.4

 

5.8

 

6.1

6.3

 

 

 

 

 

RATING POINT

 

 

 

 

 

 

 

 

ARI 310/380

 

 

 

 

 

 

 

 

 

 

 

 

3

Image 3
Contents Product Profile PH Series Chassis Specifications PE Series Chassis SpecificationsExtended Cooling Performance, PE07/09/12/15 Extended Cooling Performance, PH07/09/12/15Extended Heating Performance WallMaster PTAC/PTHP Model Identification Guide Typical Unit Components and DimensionsElectric Heat Data, PE/PH 07/09K/R Electric Heat Data, PE/PH 12/15K/RExtended Wall Sleeve Installation and Sealant Locations Pxwe Typical Wall Sleeve Installation PxwsInternal Drain Kit Location and Installation PXDR10 Architectural Louver Installation PxaaExternal Drain WallMaster PTAC/PTHP Engineering Specifications New Construction Accessories Friedrich Ptac AccessoriesChassis Options Additional AccessoriesRevised 8/01 Wallmaster P-SERIES Packaged Terminal AIR Conditioners Multiple solutions

PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS specifications

Friedrich Packaged Terminal Air Conditioners (PTACs) and Heat Pumps represent a cutting-edge solution for climate control in a variety of settings, especially in hotels, apartments, and commercial spaces. These units are designed to provide individual room temperature management, offering both heating and cooling options to ensure comfort year-round.

One of the standout features of Friedrich PTACs is their energy efficiency. These units often meet or exceed ENERGY STAR certification, which signifies superior efficiency compared to traditional models. This efficiency translates to lower energy bills and a reduced environmental footprint, making them a sustainable choice for modern building owners.

Friedrich utilizes advanced technologies in their PTAC units to enhance performance and reliability. This includes features like variable-speed compressors that adjust cooling and heating output based on real-time room demands, leading to more consistent temperatures and improved energy savings. Additionally, some units come equipped with digital controls and remote management capabilities, allowing users to easily monitor and adjust settings from a distance.

Another key characteristic of Friedrich PTACs is their quiet operation. By incorporating sound-reducing technologies and design features, these units minimize operational noise, creating a more pleasant environment for occupants. This is particularly important in settings like hotels and hospitals, where peace and quiet are paramount.

Friedrich's commitment to durability is evident in their robust construction. The units are built with high-quality materials designed to withstand the rigors of constant use, ensuring longevity. The design also includes easily accessible components for convenient maintenance and servicing, which helps to further extend the life of the unit.

Moreover, Friedrich offers a variety of models tailored to diverse installation needs. With options for different capacities, styles, and aesthetic finishes, building owners can find the perfect match for their spaces without sacrificing performance.

In conclusion, Friedrich Packaged Terminal Air Conditioners and Heat Pumps are an excellent choice for anyone looking to enhance indoor climate control. With their energy efficiency, advanced technologies, quiet operation, and durable construction, they set a high standard in the HVAC industry, ensuring comfort for occupants while also addressing the growing demand for environmentally sustainable solutions.